Appl Clin Inform 2023; 14(04): 693-704
DOI: 10.1055/s-0043-1771394
Research Article

Development and Validation of SafeHIT: An Instrument to Assess the Self-Reported Safe Use of Health Information Technology

Lizawati Salahuddin
1   Center for Advanced Computing Technology (C-ACT) Fakulti Teknologi Maklumat dan Komunikasi, Universiti Teknikal Malaysia Melaka (UTeM), Durian Tunggal, Melaka, Malaysia
,
Zuraini Ismail
2   Kuala Lumpur, Malaysia
,
Fiza Abdul Rahim
3   Advanced Informatics Department Razak Faculty of Technology and Informatics, Universiti Teknologi Malaysia (UTM), Kuala Lumpur, Malaysia
,
Syarulnaziah Anawar
1   Center for Advanced Computing Technology (C-ACT) Fakulti Teknologi Maklumat dan Komunikasi, Universiti Teknikal Malaysia Melaka (UTeM), Durian Tunggal, Melaka, Malaysia
,
Ummi Rabaah Hashim
1   Center for Advanced Computing Technology (C-ACT) Fakulti Teknologi Maklumat dan Komunikasi, Universiti Teknikal Malaysia Melaka (UTeM), Durian Tunggal, Melaka, Malaysia
› Author Affiliations

Funding This work was supported by Universiti Teknikal Malaysia Melaka (UTeM) research grant (grant number: JURNAL/2020/FTMK/Q00055) and the Ministry of Higher Education (MOHE) Malaysia.
Preview

Abstract

Background Implementing health information technology (HIT) may cause unintended consequences and safety risks when incorrectly designed and used. Yet, the tools to assess self-reported safe use of HIT are not well established.

Objective This study aims to develop and validate SafeHIT, an instrument to assess self-reported safe use of HIT among health care practitioners.

Methods Systematic literature review and a semistructured interview with 31 experts were adopted to generate SafeHIT instrument items. In total, 450 physicians from various departments at three Malaysian public hospitals participated in the questionnaire survey to validate SafeHIT. Exploratory factor analysis and confirmatory factor analysis (CFA) were undertaken to explore the items that best represent a specific construct and to confirm the reliability and validity of the SafeHIT, respectively.

Results The final SafeHIT consisted of 14 constructs and 58 items in total. The result of the CFA confirmed that all constructs demonstrated adequate convergent and discriminant validity.

Conclusion A reliable and valid theoretically underpinned measure of determinants of safe HIT use behavior has been developed. Understanding external factors that influence safe HIT use is useful for developing targeted interventions that favor the quality and safety of health care.

Protection of Human and Animal Subjects

The study was performed in compliance with the Ethical Principles for Medical Research Involving Human Subjects and received ethics approval from Malaysia's Ministry of Health Medical Review and Ethics Committee.


Supplementary Material