Applied Clinical Informatics, Table of Contents Appl Clin Inform 2014; 05(01): 232-248DOI: 10.4338/ACI-2013-10-RA-0079 Research Article Schattauer GmbH Home blood pressure monitoring, secure electronic messaging and medication intensification for improving hypertension controlA mediation analysis J.D. Ralston 1 Group Health Research Institute 1730 Minor Ave, Suite 1600, Seattle, WA 98101–1448 , A.J. Cook 1 Group Health Research Institute 1730 Minor Ave, Suite 1600, Seattle, WA 98101–1448 , M.L. Anderson 1 Group Health Research Institute 1730 Minor Ave, Suite 1600, Seattle, WA 98101–1448 , S.L. Catz 1 Group Health Research Institute 1730 Minor Ave, Suite 1600, Seattle, WA 98101–1448 , P.A. Fishman 1 Group Health Research Institute 1730 Minor Ave, Suite 1600, Seattle, WA 98101–1448 , J. Carlson 1 Group Health Research Institute 1730 Minor Ave, Suite 1600, Seattle, WA 98101–1448 , R. Johnson 1 Group Health Research Institute 1730 Minor Ave, Suite 1600, Seattle, WA 98101–1448 , B.B. Green 1 Group Health Research Institute 1730 Minor Ave, Suite 1600, Seattle, WA 98101–1448› Author AffiliationsRecommend Article Abstract Full Text PDF Download Keywords KeywordsPersonal health records - patient-provider communication - telemedicine and telehealth - remote monitoring - internet portal - patient self-care - home care and e-health References References 1 Agarwal R, Bills JE, Hecht TJ, Light RP. Role of home blood pressure monitoring in overcoming therapeutic inertia and improving hypertension control: a systematic review and meta-analysis. Hypertension 2011; 57: 29-38. 2 Okonofua EC, Simpson KN, Jesri A, Rehman SU, Durkalski VL, Egan BM. Therapeutic inertia is an impediment to achieving the Healthy People 2010 blood pressure control goals. Hypertension 2006; 47: 345-351. 3 Vrijens B, Vincze G, Kristanto P, Urquhart J, Burnier M. Adherence to prescribed antihypertensive drug treatments: longitudinal study of electronically compiled dosing histories. BMJ 2008; 336: 1114-1117. 4 Green BB, Cook AJ, Ralston JD, Fishman PA, Catz SL, Carlson J, Carrell D, Tyll L, Larson EB, Thompson RS. Effectiveness of home blood pressure monitoring, web communication, and pharmacist care on hyper-tension control: a randomized controlled trial. JAMA 2008; 299: 2857-2867. 5 Magid DJ, Ho PM, Olson KL, Brand DW, Welch LK, Snow KE, Lambert-Kerzner AC, Plomondon ME, Havranek EP. A multimodal blood pressure control intervention in 3 healthcare systems. Am J Manag Care 2011; 17: e96-e103. 6 Weber CA, Ernst ME, Sezate GS, Zheng S, Carter BL. Pharmacist-physician comanagement of hypertension and reduction in 24-hour ambulatory blood pressures. Arch Intern Med 2010; 170: 1634-1639. 7 McLean DL, McAlister FA, Johnson JA, King KM, Makowsky MJ, Jones CA, Tsuyuki RT. A randomized trial of the effect of community pharmacist and nurse care on improving blood pressure management in patients with diabetes mellitus: study of cardiovascular risk intervention by pharmacists-hypertension (SCRIP-HTN). Arch Intern Med 2008; 168: 2355-2361. 8 Ralston JD, Carrell D, Reid R, Anderson M, Moran M, Hereford J. Patient web services integrated with a shared medical record: patient use and satisfaction. J Am Med Inform Assoc. 2007; 14: 798-806. 9 Green BB, Ralston JD, Fishman PA, Catz SL, Cook A, Carlson J, Tyll L, Carrell D, Thompson RS. Electronic communications and home blood pressure monitoring (e-BP) study: design, delivery, and evaluation framework. Contemp Clin Trials 2008; 29: 376-395. 10 Coleman A, Freeman P, Steel S, Shennan A. Validation of the Omron 705IT (HEM-759-E) oscillometric blood pressure monitoring device according to the British Hypertension Society protocol. Blood Press Monit 2006; 11: 27-32. 11 O’Brien E, Waeber B, Parati G, Staessen J, Myers MG. Blood pressure measuring devices: recommendations of the European Society of Hypertension. BMJ 2001; 322: 531-536. 12 Wagner EH, Austin BT, Von Korff M. Organizing care for patients with chronic illness. Milbank Q 1996; 74: 511-544. 13 Verberk WJ, Kroon AA, Kessels AG, de Leeuw PW. Home blood pressure measurement: a systematic review. J Am Coll Cardiol 2005; 46: 743-751. 14 Bandura A. Self-efficacy: The exercise of control. NY, NY: W. H. Freeman; 1997 15 Carrell D, Ralston JD. Messages, Strands and Threads: Measuring Electronic Patient-Provider Messaging. American Medical Informatics Association Annual Session.. Washington DC: 2005 16 Schmittdiel JA, Uratsu CS, Karter AJ, Heisler M, Subramanian U, Mangione CM, Selby JV. Why don’t diabetes patients achieve recommended risk factor targets? Poor adherence versus lack of treatment intensification. J Gen Intern Med 2008; 23: 588-594. 17 Karter AJ, Parker MM, Moffet HH, Ahmed AT, Schmittdiel JA, Selby JV. New prescription medication gaps: a comprehensive measure of adherence to new prescriptions. Health Serv Res 2009; 44: 1640-1661. 18 Haynes RB, Ackloo E, Sahota N, McDonald HP, Yao X. Interventions for enhancing medication adherence. Cochrane Database Syst Rev. 2008 CD000011. 19 Jacobs Jr., DR, Ainsworth BE, Hartman TJ, Leon AS. A simultaneous evaluation of 10 commonly used physical activity questionnaires. Med Sci Sports Exerc 1993; 25: 81-91. 20 Beresford SA, Thompson B, Feng Z, Christianson A, McLerran D, Patrick DL. Seattle 5 a Day worksite program to increase fruit and vegetable consumption. Prev Med 2001; 32: 230-238. 21 Glasgow RE, Wagner EH, Schaefer J, Mahoney LD, Reid RJ, Greene SM. Development and validation of the Patient Assessment of Chronic Illness Care (PACIC). Med Care 2005; 43: 436-444. 22 Hibbard JH, Stockard J, Mahoney ER, Tusler M. Development of the Patient Activation Measure (PAM): conceptualizing and measuring activation in patients and consumers. Health Serv Res 2004; 39: 1005-1026. 23 Baron RM, Kenny DA. The moderator-mediator variable distinction in social psychological research: conceptual, strategic, and statistical considerations. J Pers Soc Psychol 1986; 51: 1173-1182. 24 Zou G. A modified poisson regression approach to prospective studies with binary data. Am J Epidemiol 2004; 159: 702-706. 25 Magid DJ, Olson KL, Billups SJ, Wagner NM, Lyons EE, Kroner BA. A pharmacist-led, American Heart Association Heart360 Web-enabled home blood pressure monitoring program. Circ Cardiovasc Qual Outcomes 2013; 6: 157-163. 26 Margolis KL, Asche SE, Bergdall AR, Dehmer SP, Groen SE, Kadrmas HM, Kerby TJ, Klotzle KJ, Maciosek MV, Michels RD, O’Connor PJ, Pritchard RA, Sekenski JL, Sperl-Hillen JM, Trower NK. Effect of home blood pressure telemonitoring and pharmacist management on blood pressure control: a cluster randomized clinical trial. JAMA 2013; 310: 46-56. 27 Ralston JD, Hirsch IB, Hoath J, Mullen M, Cheadle A, Goldberg HI. Web-based collaborative care for type 2 diabetes: a pilot randomized trial. Diabetes Care 2009; 32: 234-239. 28 Simon GE, Ralston JD, Savarino J, Pabiniak C, Wentzel C, Operskalski BH. Randomized trial of depression follow-up care by online messaging. J Gen Intern Med 2011; 26: 698-704. 29 Borowitz SM, Wyatt JC. The origin, content, and workload of e-mail consultations. JAMA 1998; 280: 1321-1324. 30 Widman LE, Tong DA. Requests for medical advice from patients and families to health care providers who publish on the World Wide Web. Arch Intern Med 1997; 157: 209-212. 31 Halamka JD, Mandl KD, Tang PC. Early experiences with personal health records. J Am Med Inform Assoc 2008; 15: 1-7. 32 Weingart SN, Rind D, Tofias Z, Sands DZ. Who uses the patient internet portal? The PatientSite experience. J Am Med Inform Assoc 2006; 13: 91-95. 33 Zhou YY, Garrido T, Chin HL, Wiesenthal AM, Liang LL. Patient access to an electronic health record with secure messaging: impact on primary care utilization. Am J Manag Care 2007; 13: 418-424.