Appl Clin Inform 2013; 04(03): 359-375
DOI: 10.4338/ACI-2013-04-RA-0019
Research Article
Schattauer GmbH

Developing Software to “Track and Catch” Missed Follow-up of Abnormal Test Results in a Complex Sociotechnical Environment

M. Smith
1  Houston VA HSR&D Center of Excellence and The Center of Inquiry to Improve Outpatient Safety Through Effective Electronic Communication, Michael E. DeBakey Veterans Affairs Medical Center and the Section of Health Services Research, Department of Medicine, Baylor College of Medicine, Houston, Texas
,
D. Murphy
1  Houston VA HSR&D Center of Excellence and The Center of Inquiry to Improve Outpatient Safety Through Effective Electronic Communication, Michael E. DeBakey Veterans Affairs Medical Center and the Section of Health Services Research, Department of Medicine, Baylor College of Medicine, Houston, Texas
,
A. Laxmisan
1  Houston VA HSR&D Center of Excellence and The Center of Inquiry to Improve Outpatient Safety Through Effective Electronic Communication, Michael E. DeBakey Veterans Affairs Medical Center and the Section of Health Services Research, Department of Medicine, Baylor College of Medicine, Houston, Texas
,
D. Sittig
2  University of Texas School of Biomedical Informatics and the UT-Memorial Hermann Center for Healthcare Quality & Safety, Houston, Texas
,
B. Reis
1  Houston VA HSR&D Center of Excellence and The Center of Inquiry to Improve Outpatient Safety Through Effective Electronic Communication, Michael E. DeBakey Veterans Affairs Medical Center and the Section of Health Services Research, Department of Medicine, Baylor College of Medicine, Houston, Texas
,
A. Esquivel
3  Department of Clinical Effectiveness and Performance Measurement, St. Luke’s Episcopal Health System, Houston, Texas
,
H. Singh
1  Houston VA HSR&D Center of Excellence and The Center of Inquiry to Improve Outpatient Safety Through Effective Electronic Communication, Michael E. DeBakey Veterans Affairs Medical Center and the Section of Health Services Research, Department of Medicine, Baylor College of Medicine, Houston, Texas
› Institutsangaben
Weitere Informationen

Correspondence to:

Michael W. Smith, PhD
VA Medical Center (152)
2002 Holcombe Blvd
Houston, TX 77030
Telefon: (713) 791–1414 x6553   
Fax: 713–748–7359   

Publikationsverlauf

received: 05. April 2013

accepted: 08. Juli 2013

Publikationsdatum:
20. Dezember 2017 (online)

 

Summary

Background: Abnormal test results do not always receive timely follow-up, even when providers are notified through electronic health record (EHR)-based alerts. High workload, alert fatigue, and other demands on attention disrupt a provider’s prospective memory for tasks required to initiate follow-up. Thus, EHR-based tracking and reminding functionalities are needed to improve follow-up.

Objectives: The purpose of this study was to develop a decision-support software prototype enabling individual and system-wide tracking of abnormal test result alerts lacking follow-up, and to conduct formative evaluations, including usability testing.

Methods: We developed a working prototype software system, the Alert Watch And Response Engine (AWARE), to detect abnormal test result alerts lacking documented follow-up, and to present context-specific reminders to providers. Development and testing took place within the VA’s EHR and focused on four cancer-related abnormal test results. Design concepts emphasized mitigating the effects of high workload and alert fatigue while being minimally intrusive. We conducted a multifaceted formative evaluation of the software, addressing fit within the larger socio-technical system. Evaluations included usability testing with the prototype and interview questions about organizational and workflow factors. Participants included 23 physicians, 9 clinical information technology specialists, and 8 quality/safety managers.

Results: Evaluation results indicated that our software prototype fit within the technical environment and clinical workflow, and physicians were able to use it successfully. Quality/safety managers reported that the tool would be useful in future quality assurance activities to detect patients who lack documented follow-up. Additionally, we successfully installed the software on the local facility’s “test” EHR system, thus demonstrating technical compatibility.

Conclusion: To address the factors involved in missed test results, we developed a software prototype to account for technical, usability, organizational, and workflow needs. Our evaluation has shown the feasibility of the prototype as a means of facilitating better follow-up for cancer-related abnormal test results.


#

 


#