Abstract
Background: Can Contegra grafts withstand high pressure? Methods: The function of Contegra grafts implanted after unifocalization of major aortopulmonary
collateral arteries (MAPCAs) in 10 patients was evaluated. Median age at repair was
194 days and two conduit sizes were used: 12 mm (n = 8) and 14 mm (n = 2). Echocardiography
and heart catheterization findings were reviewed. Results: Two patients died: one early after repair, one late. Death was not graft related.
The median duration of observation for survivors was 31 (range 4 – 42) months. The
postoperative right ventricular/left ventricular pressure ratio was greater than 75 %
in 9 patients. High pressures persisted in 6 survivors. Seven patients underwent interventional
dilatation/stenting of pulmonary arteries on 19 occasions. No obstruction was detected
in the conduit. Graft valve regurgitation increased in 5 patients, but never exceeded
grade 2 (n = 4). Freedom from reoperation for conduit dysfunction/failure was 100 %
at month 42. Conclusion: At mid-term follow-up, the Contegra grafts withstood high pressure without significant
dysfunction or aneurysmal dilatation requiring surgery. Contegra appears to be an
acceptable alternative to the aortic homograft for use after unifocalization of MAPCAs
in infancy.
Key words
cardiovascular surgery - heart valve surgery - heart disease
References
- 1
Sinzobahamvya N, Wetter J, Blaschczok H C, Cho M Y, Brecher A M, Urban A E.
The fate of small-diameter homografts in the pulmonary position.
Ann Thorac Surg.
2001;
72
2070-2076
- 2
Perry G J, Helmcke F, Nanda N C, Byarad C, Soto B.
Evaluation of aortic insufficiency by Doppler color flow mapping.
J Am Coll Cardiol.
1987;
9
952-959
- 3
Shebani S O, McGuirk S, Baghai M, Stickley J, De Giovanni J V, Bu'Lock F A, Barron D J,
Brawn W J.
Right ventricular outflow tract reconstruction using Contegra® valved conduit: natural
history and conduit performance under pressure.
Eur J Cardiothorac Surg.
2006;
29
397-405
- 4
Sekarski N, van Meir H, Rijlaarsdam M EB, Schoof P H, Koolbergen D R, Hruda J, von
Segesser L K, Meijboom E J, Hazekamp M G.
Right ventricular outflow tract reconstruction with the bovine jugular vein graft:
5 years' experience with 133 patients.
Ann Thorac Surg.
2007;
84
599-605
- 5
Morales D LS, Braud B E, Gunter K S, Carberry K E, Arrington K A, Heinle J S, McKenzie E D,
Fraser Jr C D.
Encouraging results for the Contegra conduit in the problematic right ventricle-to-pulmonary
artery connection.
J Thorac Cardiovasc Surg.
2006;
132
665-671
- 6
Tiete A R, Sachweh J S, Roemer U, Kozlik-Feldmann R, Reichart B, Daebritz S H.
Right ventricular outflow tract reconstruction with the Contegra bovine jugular vein
conduit: a word of caution.
Ann Thorac Surg.
2004;
77
2151-2156
- 7
Rastan A J, Walther T, Daehnert I, Hambsch J, Mohr F W, Janousek J, Kostelka M.
Bovine jugular vein conduit for right ventricular outflow tract reconstruction: evaluation
of risk factors for mid-term outcome.
Ann Thorac Surg.
2006;
82
1308-1315
- 8
Brown J W, Rutzmetov M, Rodefeld M D, Vijay P, Darragh R K.
Valved bovine jugular vein conduits for right ventricular outflow tract reconstruction
in children: an attractive alternative to pulmonary homograft.
Ann Thorac Surg.
2006;
82
909-916
- 9
Boudjemline Y, Bonnet D, Agnoletti G, Vouhé P.
Aneurysm of the right ventricular outflow following bovine valved venous conduit insertion.
Eur J Cardiothorac Surg.
2003;
23
122-124
- 10
Sinzobahamvya N, Asfour B, Boscheinen M, Photiadis J, Fink C, Schindler E, Hraska V,
Brecher A M.
Compared fate of small-diameter Contegras® and homografts in the pulmonary position.
Eur J Cardiothorac Surg.
2007;
32
209-214
- 11
Breymann T, Thies W-R, Boething D, Goerg R, Blanz U, Koerfer R.
Bovine valved venous xenografts for RVOT reconstruction: results after 71 implantations.
Eur J Cardiothorac Surg.
2002;
21
703-710
Dr. Nicodème Sinzobahamvya
Pediatric Thoracic and Cardiovascular Surgery
Deutsches Kinderherzzentrum Sankt Augustin
Arnold-Janssen-Straße 29
53757 Sankt Augustin
Germany
Phone: + 49 (0) 22 41 24 96 01
Fax: + 49 (0) 22 41 24 96 02