Abstract

The “too-long,” or redundant, circumflex graft is notorious for its tendency to form a kink. The acute angle (the kink) typically occurs over the front of the pulmonary trunk. Described herein are (1) the left appendage flip maneuver, a simple solution to correct graft kink, and (2) analysis and explanation of vein graft kink.

 
  • References

  • 1 Galvin IF, Newman DC. Circumflex exposure using a cardiac sling. Ann Thorac Surg 1990; 49 (5) 833-834
  • 2 Galvin IF. Mammary artery grafts: a new no-touch technique for anastomosis. Ann Thorac Surg 1991; 51 (3) 500-503
  • 3 Galvin IF. New shapes and sizes: a T-tube coronary conduit. Ann Thorac Surg 1993; 56 (5) 1184-1186
  • 4 Galvin IF, Galvin SD. Top-end aortocoronary anastomosis made easy: the visor technique. J Card Surg 2010; 25 (5) 511-512
  • 5 Saxena P, Chai PH, Galvin I. Composite venous coronary grafts: construction made simple. Ann Thorac Surg 2012; 93 (4) 1324-1325