Nuklearmedizin 1995; 34(01): 40-46
DOI: 10.1055/s-0038-1629691
Original Article
Schattauer GmbH

Testmessungen an der Multispect-2-Gammakamera zum Nachweis von 511-keV- Gammastrahlung

Physical Performance of a Multispect 2 Gamma Camera for Imaging Positron Emitters
A. Schaefer
1   Aus der Abteilung Nuklearmedizin der Radiologischen Klinik der Universit&228;t des Saarlandes, Homburg, FRG
,
E. Oberhausen
1   Aus der Abteilung Nuklearmedizin der Radiologischen Klinik der Universit&228;t des Saarlandes, Homburg, FRG
› Author Affiliations
Further Information

Publication History

Received: 19 August 1994

Accepted: 01 October 1994

Publication Date:
04 February 2018 (online)

Zusammenfassung

Die physikalischen Eigenschaften einer modifizierten Multispect-2-Gamma-kamera, die mit zwei Paar, speziell zur Messung der Positronenvernichtungsstrahlung (511 keV) konstruierten Hochenergiekollimatoren ausgestattet war, wurden meßtechnisch überprüft. Die Messungen umfaßten die Bestimmung der Empfindlichkeit und des geometrischen Auflösungsvermögens. Werte für die Penetration wurden nach 2 verschiedenen Methoden näherungsweise berechnet. Die räumliche Auflösung, gemessen als FWHM einer Linienquelle in 10 cm Abstand vom Kollimator in Wasser, betrug mit Kollimator 511 _A 14,0 mm und mit Kollimator 511 _B 12,5 mm. Für die Septenpenetration wurde aus einem Gauß-Fit der Linienbildfunktion des Gesamtsystems 12% für Kollimator 511 _A und von 36% für Kollimator 511J3 berechnet. Die Nachweisempfindlichkeit für 511-keV-Strahlung betrug für Kollimator 511_A 66,7 und für Kollimator 511_B 98,7 cpm/37 kBq. Der höhere Wert von Kollimator 511_B muß jedoch teilweise durch die hohe Septenpenetration erklärt werden.

Summary

The performance of a modified Multispect 2 gamma camera, which was supplied with two pairs of collimators constructed for imaging positron emitters was tested. The measurements involved the determination of sensitivity and of spatial resolution. The septal penetration was calculated approximately using two different methods. The spatial resolution determined by FWHM as measured by planar imaging in water at 10 cm distance from the collimator was evaluated as 14.0 mm with collimator 511 _A and 12.5 mm with collimator 511J3. Using a Gaußian fit of the line-spread function septal penetrations of 12% with collimator 511_A and of 36% with collimator 511_B were calculated. The absolute system sensitivity measured with 18F was 66 cpm with collimator 511_A and 98.7 cpm/ 37 kBq with collimator 511_B. The high sensitivity with collimator 511_B may be explained, at least partially, by the high septal penetration.

 
  • LITERATUR

  • 1 Beck RN. Collimation of gamma rays. In: Fundamental problems in scanning. Gottschalk A, Beck RN. (eds). Springfield: Charles C. Thomas; 1968: 71-92.
  • 2 Fischman AJ, Alpert NM. FDG-PET in oncology: There’s more to it than looking at pictures. J Nucl Med 1993; 34: 6-11.
  • 3 Gallagher BM, Fowler JS, Gutterson NI. et al. Metabolic trapping as a principle of radiopharmaceutical design: Some factors responsible for the biodistribution of [l8F]2-Deoxy-2Fluoro-D-Glucose. J Nucl Med 1978; 19: 1154-61.
  • 4 Jordan K. Apparative Neuentwicklungen bei SPECT und PET. Der Nuklearmediziner 1992; 15: 235.
  • 5 Mather RL. Gamma-ray collimator; penetration and scattering effects. J Appl Phys 1957; 28: 1200-7.
  • 6 Newiger H. Kollimatoren für planare und tomographische Szintigraphie mit einer Gammakamera: Simulation, Messung und Optimierung. Hannover: Medizinische Hochschule; 1987. (Dissertation).
  • 7 Newiger H, Jordan K. Optimization of collimators for imaging positron emitters by a gamma camera. Eur J Nucl Med 1985; 11: 230-4.