Ultraschall Med 2011; 32: E8-E13
DOI: 10.1055/s-0031-1281650
Original Article

© Georg Thieme Verlag KG Stuttgart · New York

A New Technique for Assessing Renal Transplant Perfusion Preoperatively Using Contrast-Enhanced Ultrasound (CEUS) and Three-Dimensional Ultrasound (3DUS) – A Porcine Model Pilot Study

Eine neue Technik für die präoperative Beurteilung der Nierentransplantat-Perfusion mittels kontrastverstärkter Sonografie (CEUS) und dreidimensionalen Ultraschalls (3-DUS) – eine Pilotstudie am SchweinemodellB. Stenberg1 , D. Talbot2 , M. Khurram2 , A. Kanwar2 , C. Ray2 , O. Mownah2 , K. White3 , S. T. Elliott1
  • 1Radiology, Freeman Hospital
  • 2Transplant Surgery, Freeman Hospital
  • 3EM Research Services, Newcastle University
Weitere Informationen

Publikationsverlauf

received: 18.1.2011

accepted: 18.6.2011

Publikationsdatum:
16. Dezember 2011 (online)

Zusammenfassung

Ziel: Diese Pilotstudie hat das Ziel, die Durchführbarkeit des kontrastverstärkten Ultraschalls (CEUS) in Nierentransplantaten zu bewerten, die sich vor Transplantation an hypothermen Perfusionsmaschinen befinden. Wir beurteilen die renale Durchblutung der Maschinen-perfundierten porcinen Nieren mit CEUS (Mastricht-Kategorie II). Material und Methoden: 5 Nieren wurden bis zu 24 h nach Ankunft an die hypotherme Maschinenperfusion angeschlossen. Die Nieren wurden dann mit einer Niedrig-MI-kontrastspezifischen Voreinstellung gescannt und ein Bolus von 0,5 ml Sonovue-Kontrastmittel wurde verabreicht. Die kontrastspezifischen Ultraschallbilder wurden in 2-D und 3-D aufgenommen. Ergebnisse: An der Perfusionsmaschine zeigten die 5 Nieren variable Flussraten (10 – 37 ml/min bei 30 mmHg). Die CEUS-Technik stellte in 4 Nieren gute Perfusion und Strömungsprofile dar, die den in vivo gesehenen entsprachen. Eine Niere hatte bis zur interlobären Region durchgängige Arterien, aber keine Kontrastfüllung in Rinde oder Mark. Kleine Perfusionsdefekte wurden in 2 der perfundierten Nieren gesehen. Schlussfolgerung: CEUS scheint eine brauchbare Methode zur Bestimmung der globalen Perfusion und kleiner Defekte in Nieren vor Transplantation zu sein. Die Flussmuster in vitro scheinen denen in vivo zu entsprechen und es ist noch weitere Arbeit erforderlich, um die Relevanz der gemessenen Durchflussdynamiken zu bewerten.

Abstract

Purpose: This pilot study aims to assess the viability of using contrast-enhanced ultrasound (CEUS) in renal grafts while they are on hypothermic perfusion machines prior to transplantation. We assessed the vascularity and renal perfusion of machine-perfused porcine kidneys (Maastricht category II) using CEUS. Materials and Methods: Five kidneys were placed on hypothermic machine perfusion for up to 24 hours after retrieval. The kidneys were then scanned with a low MI contrast-specific preset and a bolus of 0.5ml of Sonovue contrast agent was administered. Contrast-specific ultrasound images of the kidney were acquired in 2D and 3D. Results: The five kidneys demonstrated variable flow rates on the perfusion machine (10 – 37 ml/min at 30 mmHg). The CEUS technique demonstrated good perfusion and flow patterns, similar to those seen in vivo, in four kidneys. One kidney had patent arteries up to the interlobar region but no contrast filling in the cortex or medulla. Small perfusion defects were seen in two of the perfused kidneys. Conclusion: CEUS appears to be a viable technique for assessing global perfusion and small defects within kidneys prior to transplantation. The flow patterns seen in vitro appear to correspond to those seen in vivo. Further work is required to evaluate the relevance of the flow dynamics measured.

References

  • 1 Global Observatory on Donation & Transplantation .http://www.transplant-observatory.org (online) (accessed 11 / 08 / 10)
  • 2 National Kidney Foundation .http://www.kidney.org.uk/campaigns/ Press-Media/nkf-press-oct06.html (online)(accessed 26 / 03 / 10)
  • 3 Moers C, Smits J M, Maathuis M J. Machine Perfusion or Cold Storage in Deceased-Donor Kidney Transplantation.  N Engl J Med. 2009;  360 7-19
  • 4 Talbot D, Shenton B K, Buckley P E et al. Experiences learned in the successful establishment of a nonheart beating donor program for renal transplantation.  J Urology. 2003;  170 1088-1092
  • 5 Choi J D et al. Renal Damage Caused by Warm Ischaemia During Laparoscopic and Robot- Assisted Partial Nephrectomy: An Assessment Using Tc 99m-DTPA Glomerular Filtration Rate.  Eur Urol. 2010;  DOI: 10.1016 / j.eururo.2010.08.044
  • 6 Lefèvre F, Correas J M, Briançon S. Contrast-enhanced sonography of the renal transplant using triggered pulse-inversion imaging: preliminary results.  Ultrasound Med Biol. 2002;  28 303-314
  • 7 Fischer T, Filimonow S, Rudolph J. Arrival time parametric imaging: a new ultrasound technique for quantifying perfusion of kidney grafts.  Ultraschall in Med. 2008;  29 418-423
  • 8 Kay D H, Mazonakis C, Geddes C et al. Ultrasonic microbubble contrast agents and the transplant kidney.  Clin Radiol. 2009;  64 1081-1087
  • 9 Stenberg B, Elliott S T. Diagnosis of gallbladder problems using three-dimensional ultrasound.  Eur Radiol. 2010;  20 908-914
  • 10 Fischer T, Filimonow S, Dieckhöfer J. Improved diagnosis of early kidney allograft dysfunction by ultrasound with echo enhancer – a new method for the diagnosis of renal perfusion.  Nephrol Dial Transplant. 2006;  21 2921-2929
  • 11 Kay D H, Mazonakis C, Geddes C et al. Ultrasonic microbubble contrast agents and the transplant kidney.  Clin Radiol. 2009;  64 1081-1087
  • 12 Wagner M, Rhodes G, Wang C et al. Ischemic Injury to Kidney Induces Glomerular Podocyte Effacement and Dissociation of Slit Diaphragm Proteins Neph1 and ZO-1.  Journal of Biological Chemistry. 2008;  283 35 579-35 589
  • 13 Cosgrove D, Eckersley R. Contrast enhanced ultrasound: basic physics and technology overview. Chapter in Enhancing the role of ultrasound with contrast agents (edited by Lencioni R.) Italy: Springer-Verlag; 2006
  • 14 Chen N G, Fowlkes J B, Carson P L et al. Rapid 3-D imaging of contrast flow: application in a perfused kidney phantom.  Ultrasound med biol. 2009;  35 813-828
  • 15 Quaia E (edited by). Contrast media in ultrasonography. Berlin: Springer-Verlag; 2005
  • 16 Bracco Ltd. .Contrast enhanced ultrasound…explore life from the inside: Radiology Monograph. Bracco UK Ltd; 2010
  • 17 Jimenez C, Gracia de R, Aguilera A. In Situ Kidney Insonation With Microbubble Contrast Agents Does Not Cause Renal Tissue Damage in a Porcine Model.  J Ultrasound Med. 2008;  27 1607-1615
  • 18 Miller D J, Dou C, Wiggins R C. Contrast-enhanced diagnostic ultrasound causes renal tissue damage in a porcine model.  J Ultrasound Med. 2010;  29(10) 1391-1401

Benjamin Stenberg

Radiology, Freeman Hospital

Freeman Road

NE7 7DN Newcastle upon Tyne

England UK

Telefon: + 44/1 91/2 33 61 61

Fax: + 44/1 91/2 23 11 68

eMail: ben.stenberg@nuth.nhs.uk

    >