Thorac Cardiovasc Surg 2009; 57(4): 209-213
DOI: 10.1055/s-2008-1039315
Original Cardiovascular

© Georg Thieme Verlag KG Stuttgart · New York

Transaortic Stent Grafting for Distal Arch Aneurysm with Antegrade and Retrograde Extracorporeal Circulation

K. Akiyama1 , K.-I. Nakata1 , S. Kasiwazaki1 , S. Fukushima2
  • 1Cardiovascular Surgery, Nihon University Nerima Hikarigaoka Hospital, Tokyo, Japan
  • 2Cardiology, Nihon University Nerima Hikarigaoka Hospital, Tokyo, Japan
Further Information

Publication History

received June 27, 2008

Publication Date:
20 May 2009 (online)

Preview

Abstract

Purpose: The purpose of this study was to determine whether cerebrospinal cord injury can be avoided with transaortic stent grafting for distal aortic aneurysm, and whether this technique can be widely used.

Methods: Seventeen patients underwent distal aortic aneurysm repair with the transaortic stent grafting technique. All patients had a median sternotomy with combined antegrade and retrograde perfusion and selective cerebral perfusion. The stent graft was inserted via an aortotomy at the aortic arch. We evaluated the aneurysms on computed tomography scan 2 weeks and 3 months after surgery.

Results: The follow-up period ranged from 3 to 85 months. There was no operative mortality or cerebrospinal dysfunction. Reoperation was performed in two patients. One patient died 15 days after the second operation. Postoperative computed tomography scan showed early thrombosis of the excluded aneurysmal space in 15 (88.2 %) patients.

Conclusion: Cerebrospinal cord injury could be avoided by selecting lesions for indications and using a combination of antegrade and retrograde perfusion. This surgical technique is useful for arch aneurysms and can be widely used.

References

Dr. Kenji Akiyama

Cardiovascular Surgery
Nihon University Nerima Hikarigaoka Hospital

2-11-1 Hikarigaoka, Nerimaku

179-0072 Tokyo

Japan

Phone: + 81 3 39 79 36 11

Fax: + 81 3 39 79 38 68