Endoscopy 2004; 36(8): 710-714
DOI: 10.1055/s-2004-825658
Original Article
© Georg Thieme Verlag KG Stuttgart · New York

Use of the Curved Linear-Array Echo Endoscope to Identify Gastrorenal Shunts in Patients with Gastric Fundal Varices

H.  Kakutani1 , S.  Hino1 , K.  Ikeda1 , T.  Mashiko1 , K.  Sumiyama1 , Y.  Uchiyama1 , A.  Kuramochi1 , Y.  Kitamura1 , K.  Matsuda1 , M.  Kawamura1 , H.  Tajiri1 , M.  Urashima2
  • 1 Department of Endoscopy, Jikei University School of Medicine, Tokyo, Japan
  • 2 Division of Clinical Research and Development, Jikei University School of Medicine, Tokyo, Japan
Weitere Informationen

Publikationsverlauf

Submitted 5 September 2003

Accepted after Revision 4 April 2004

Publikationsdatum:
28. Juli 2004 (online)

Preview

Background and Study Aims: Balloon-occluded retrograde transvenous obliteration (B-RTO) has emerged as an effective, minimally invasive treatment for fundal varices. B-RTO requires a spontaneously developed gastrorenal shunt as a pathway for the balloon catheter to reach the fundal varices. We used a curved linear-array (CLA) echo endoscope in patients with fundal varices to identify gastrorenal shunts, and compared the detection rate with the gold standard, contrast-enhanced computed tomography (CECT).
Patients and Methods: A total of 40 patients with fundal varices were examined with both CLA echo endoscopy and CECT. The CECT images were retrospectively and independently evaluated by two gastroenterologists who were unaware of the clinical details, including the results of the CLA echo endoscopy.
Results: CLA echo endoscopy identified gastrorenal shunts in 26/40 patients with fundal varices. It visualized the shunt in a longitudinal direction and provided images of the connections of the shunt at both ends, the fundal varices and the left renal vein/branch of the inferior adrenal vein. The kappa index for CLA echo endoscopy and CECT for the identification of gastrorenal shunt was 0.9 (95 % CI, 0.6 to 1.0). When the cutoff point for the diameter of the gastrorenal shunt detected by the CLA echo endoscope was set at equal to or greater than 5 mm, the kappa index was 1.0 (95 % CI, 0.7 to 1.0).
Conclusions: These results suggest that CLA echo endoscopy can successfully identify gastrorenal shunt and provide detailed morphological information. It also efficiently identifies patients suitable for B-RTO, particularly in cases of acute bleeding. It also has considerable potential for providing detailed information with regard to the treatment of gastric varices.

References

H. Kakutani, M.D.

Department of Endoscopy · Jikei University School of Medicine

Nishi-shimbashi 3-25-8, Minato-ku · Tokyo · Japan, 105-8461

Fax: + 81-3-3459-4524

eMail: endosc-kaku@jikei.ac.jp