Am J Perinatol 2001; 18(3): 129-136
DOI: 10.1055/s-2001-14527
ORIGINAL ARTICLE

Copyright © 2001 by Thieme Medical Publishers, Inc., 333 Seventh Avenue, New York, NY 10001, USA. Tel.: +1(212) 584-4662

Lack of Relationship Between Variable Decelerations During Reactive Nonstress Tests and Oligohydramnios

Chris Glantz, Mary Lou D'Amico
  • Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, University of Rochester School of Medicine and Dentistry, Rochester, New York
Further Information

Publication History

Publication Date:
31 December 2001 (online)

ABSTRACT

We sought to prospectively determine the value of variable and lambda decelerations noted during nonstress tests in predicting oligohydramnios and perinatal outcome. On the same day as having had reactive nonstress tests, 651 women underwent obstetrical ultrasound examinations for amniotic fluid index (AFI). Lambda and variable fetal heart rate decelerations were identified on sets of otherwise-reactive nonstress tests. Those with variable decelerations composed group 1; those without variable decelerations composed group 2. Demographic, perinatal outcome, and AFI data were compared, and group 1 inclusion criteria were varied. There were 200 nonstress tests in group 1 and 490 in group 2. There was a small difference between groups in maternal age (1.2 years, p = 0.02) and gestational age (0.8 weeks, p = 0.01), but no differences in gravidity, parity, race, or indications for testing (p >0.05). Oligohydramnios was present in 14.5% in group 1 and in 13.3% of group 2 (p = 0.68). In the cases of amniotic fluid index <8 cm, depth and duration of the variable decelerations did not correlate with AFI (R 2 = 0.11, p = 0.09). Variable decelerations were associated with intrapartum ``fetal distress,'' but lambda decelerations did not correlate with any outcome. Variable decelerations on an otherwise-reactive nonstress test did not correlate with amniotic fluid volume and were not cause for intervention in this study.

REFERENCES

  • 1 Barcroft J. Researches on pre-natal life.  Springfield: Charles C. Thomas; 1947
  • 2 Ball R H, Parer J T. The physiologic mechanism of variable decelerations.  Am J Obstet Gynecol . 1992;  166 1683-1689
  • 3 Harding J A, Jackson D M, Lewis D F. Correlation of amniotic fluid index and nonstress test in patients with preterm premature rupture of membranes.  Am J Obstet Gynecol . 1991;  165 1088-1094
  • 4 Hoskins I A, Frieden F J, Young B K. Variable decelerations in reactive nonstress tests with decreased amniotic fluid index predict fetal compromise.  Am J Obstet Gynecol . 1991;  165 1094-1098
  • 5 Rutherford S E, Phelan J P, Smith C V, Jacobs N. The four-quadrant assessment of amniotic fluid volume: an adjunct to antepartum fetal heart rate testing.  Obstet Gynecol . 1987;  70 353-356
  • 6 Eden R D, Gergely R Z, Schifrin B S, Wade M E. Comparison of antepartum testing schemes for the management of the postdate pregnancy.  Am J Obstet Gynecol . 1982;  144 683-692
  • 7 Judge N E, Mann L I, Lupe P. Clinical associations of variable decelerations during reactive nonstress tests.  Obstet Gynecol . 1989;  74 351-356
  • 8 Meis P J, Ureda J R, Swain M. Variable decelerations during nonstress tests are not a sign of fetal compromise.  Am J Obstet Gynecol . 1986;  154 586-590
  • 9 Brubaker K, Garite T J. The lambda fetal heart rate pattern: an assessment of its significance in the intrapartum period.  Obstet Gynecol . 1988;  72 881-885
  • 10 Aladjem S, Rest J, Stojanovik J. Fetal heart rate responses to fetal movements.  Br J Obstet Gynecol . 1977;  84 487-491
  • 11 Lee C Y, Drukker B. The nonstress test for the antepartum assessment of fetal reserve.  Am J Obstet Gynecol . 1979;  134 460-470
  • 12 O'Leary J A, Andrinopoulos G C, Giordana P C. Variable decelerations and the nonstress test: an indication of cord compromise.  Am J Obstet Gynecol . 1980;  137 704-706
  • 13 Trimbos J B, Keirse M N C J. Nonspecific decelerations in fetal heart rate during high-risk pregnancy.  Br J Obstet Gynecol . 1977;  84 732-736
  • 14 Bourgeois F J, Thiagarajah S, Harbert G M. The significance of fetal heart rate decelerations during nonstress testing.  Am J Obstet Gynecol . 1984;  150 213-216
  • 15 Phelan J P, Platt L D, Yeh S Y, Trujillo M, Paul R H. Continuing role of the nonstress test in the management of postdates pregnancy.  Obstet Gynecol . 1984;  64 624-628
  • 16 Freeman R K, Anderson G, Dorchester W. A prospective multi-institutional study of antepartum fetal heart rate monitoring.  Am J Obstet Gynecol . 1982;  143 771-777
  • 17 Kubli F W, Hon E H, Khazin A F, Takemura H. Observations on heart rate and pH in the human fetus during labor.  Am J Obstet Gynecol . 1969;  104 1190-1206
    >