Am J Perinatol 2015; 32(04): 393-398
DOI: 10.1055/s-0034-1389089
Original Article
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Passive Leg Raising during Pregnancy

Nicole Ribeiro Marques
1   Department of Anesthesiology, The University of Texas Medical Branch, Galveston, Texas
,
Caroline Martinello
1   Department of Anesthesiology, The University of Texas Medical Branch, Galveston, Texas
,
George C. Kramer
1   Department of Anesthesiology, The University of Texas Medical Branch, Galveston, Texas
,
Maged M. Costantine
2   Department of Obstetrics and Gynecology, The University of Texas Medical Branch, Galveston, Texas
,
Rakesh B. Vadhera
1   Department of Anesthesiology, The University of Texas Medical Branch, Galveston, Texas
,
George R. Saade
2   Department of Obstetrics and Gynecology, The University of Texas Medical Branch, Galveston, Texas
,
Gary D. Hankins
2   Department of Obstetrics and Gynecology, The University of Texas Medical Branch, Galveston, Texas
,
Luis D. Pacheco
1   Department of Anesthesiology, The University of Texas Medical Branch, Galveston, Texas
2   Department of Obstetrics and Gynecology, The University of Texas Medical Branch, Galveston, Texas
› Author Affiliations
Further Information

Publication History

24 June 2014

09 July 2014

Publication Date:
21 September 2014 (online)

Abstract

Objective To determine if passive leg raising (PLR) significantly increases cardiac output in a cohort of healthy pregnant women during the third trimester.

Study Design Using a noninvasive monitor, baseline hemodynamic measurements for arterial blood pressure, systolic and diastolic blood pressure, heart rate, cardiac output, cardiac index, stroke volume, and systemic vascular resistances were obtained with patients in the semirecumbent position. Measurements were repeated after a 3-minute PLR maneuver in supine, right lateral decubitus, and left lateral decubitus positions.

Results After 10 minutes of bed rest, the cohort's mean baseline heart rate was 80 ± 12 beats/minute. Baseline stroke volume was 98 ± 14 mL, mean cardiac output was 7.8 ± 1.2 L/min, and mean cardiac index was 4.32 ± 0.63 L/min. The baseline systemic vascular resistance value was 893 ± 160 dynes/sec/cm5. Baseline mean arterial blood pressure was 84 ± 11 mm Hg. Following a PLR maneuver in the supine position, heart rate decreased significantly. No difference was noted in other measurements. Findings were similar with PLR in the left lateral decubitus. PLR in the right lateral decubitus resulted in significantly decreased heart rate, cardiac output, and cardiac index.

Conclusions PLR did not result in cardiac output recruitment in a cohort of healthy pregnant women during the third trimester.

Note

All work was performed at The University of Texas Medical Branch at Galveston.


 
  • References

  • 1 Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 2008; 134 (1) 172-178
  • 2 Osman D, Ridel C, Ray P , et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med 2007; 35 (1) 64-68
  • 3 Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 2009; 37 (9) 2642-2647
  • 4 Braunwald E, Sonnenblick EH, Ross J. Mechanisms of cardiac contraction and relaxation. In: Braunwald E, , ed. Heart Disease. Philadelphia, PA: WB Sanders; 1988: 383-425
  • 5 Kumar A, Anel R, Bunnell E , et al. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med 2004; 32 (3) 691-699
  • 6 Brun C, Zieleskiewicz L, Textoris J , et al. Prediction of fluid responsiveness in severe preeclamptic patients with oliguria. Intensive Care Med 2013; 39 (4) 593-600
  • 7 Mahjoub Y, Touzeau J, Airapetian N , et al. The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension. Crit Care Med 2010; 38 (9) 1824-1829
  • 8 Sugrue M. Abdominal compartment syndrome. Curr Opin Crit Care 2005; 11 (4) 333-338
  • 9 Chun R, Kirkpatrick AW. Intra-abdominal pressure, intra-abdominal hypertension, and pregnancy: a review. Ann Intensive Care 2012; 2 (Suppl. 01) S5
  • 10 Eeftinck Schattenkerk DW, van Lieshout JJ, van den Meiracker AH , et al. Nexfin noninvasive continuous blood pressure validated against Riva-Rocci/Korotkoff. Am J Hypertens 2009; 22 (4) 378-383
  • 11 Bogert LW, Wesseling KH, Schraa O , et al. Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease. Anaesthesia 2010; 65 (11) 1119-1125
  • 12 Hofhuizen CM, Lemson J, Hemelaar AE , et al. Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery. Br J Anaesth 2010; 105 (4) 493-500
  • 13 Ameloot K, Van De Vijver K, Broch O , et al. Nexfin noninvasive continuous hemodynamic monitoring: validation against continuous pulse contour and intermittent transpulmonary thermodilution derived cardiac output in critically ill patients. ScientificWorldJournal 2013; 2013: 519080