Abstract

Optical biometry has fundamentally transformed cataract surgery, and 2024 marked 25 years since the introduction of the first optical biometer. In the early 1980 s, Fercher and colleagues pioneered the optical noncontact eye length measurement, leading to the first interferometric A-scan of the eye. This innovation, patented and later developed by Zeiss, culminated in the release of the IOLMaster in 1999, enabling more accurate and reproducible eye diagnostics. Over the years, optical biometry has evolved into advanced swept-source optical coherence tomography devices, accompanied by numerous formulas for calculating intraocular lens power. Today, this technology is crucial not only for cataract surgeries, especially in eyes previously treated with refractive surgery, but also in advancing our understanding of diseases across fields like cardiology and oncology.

Zusammenfassung

Die optische Biometrie hat die Kataraktchirurgie grundlegend revolutioniert, und im Jahr 2024 wurde das 25-jährige Jubiläum seit der Einführung des ersten optischen Biometers gefeiert. In den frühen 1980er-Jahren entwickelten Fercher und Kollegen diese optische, berührungslose Biometrie, was zur ersten interferometrischen A-Scan-Aufnahme des Auges führte. Diese Innovation, die von Zeiss patentiert und später weiterentwickelt wurde, gipfelte 1999 in der Einführung des IOLMasters, der eine hochpräzise und reproduzierbare Biometrie ermöglichte. Im Laufe der Jahre hat sich die optische Biometrie weiterentwickelt und umfasst heute fortschrittliche Swept-Source-OCT-Geräte, begleitet von zahlreichen Formeln zur Berechnung der Intraokularlinsenstärke. Diese Technologie ist heutzutage nicht nur für die Kataraktchirurgie, insbesondere bei Augen, die zuvor refraktiv behandelt wurden, von entscheidender Bedeutung, sondern trägt auch zur Vertiefung unseres Verständnisses von Erkrankungen in Bereichen wie der Kardiologie und Onkologie bei.



Publication History

Received: 21 September 2024

Accepted: 28 September 2024

Accepted Manuscript online:
01 October 2024

Article published online:
05 December 2024

© 2024. Thieme. All rights reserved.

Georg Thieme Verlag KG
Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

 
  • References

  • 1 Scholtz S, Langenbucher A. [Calculating the Human Eye – The Evolution of Biometry for Cataract Surgery]. Klin Monbl Augenheilkd 2020; 237: 933-937
  • 2 Scholtz S, Cayless A, Langenbucher A. Calculating the Human Eye – Basics on Biometry. In: Liu C, Shalaby Bardan A. eds. Cataract Surgery, Pearls and Techniques. Cham: Springer; 2021: 87-114
  • 3 Kaymak H, Graff B, Schaeffel F. et al. A retrospective analysis of the therapeutic effects of 0.01 % atropine on axial length growth in children in a real-life clinical setting. Graefes Arch Clin Exp Ophthalmol 2021; 259: 3083-3092
  • 4 Queirós A, Amorim-de-Sousa A, Fernandes P. et al. Mathematical Estimation of Axial Length Increment in the Control of Myopia Progression. J Clin Med 2022; 11: 6200
  • 5 Langenbucher A, Hoffmann P, Cayless A. et al. Impact of uncertainties in biometric parameters on intraocular lens power formula predicted refraction using a Monte-Carlo simulation. Acta Ophthalmol 2024; 102: e285-e295
  • 6 Saleh B. The Laser. In: Al-Amri MD, El-Gomati MM, Zubairy MS. eds. Optics in Our Time. Cham: Springer; 2016: 71-85
  • 7 Scholtz S, Becker M, MacMorris L. et al. LASER – A solution in search of a problem. In: Scholtz S, Becker M, MacMorris L, Langenbucher A. (Editors) Curiosities in Medicine. Cham: Springer; 2023: 181-184
  • 8 Maiman T. Stimulated optical radiation in ruby. Nature 1960; 187: 493-494
  • 9 Fercher A. Optical coherence tomography – development, principles, applications. Z Med Phys 2010; 20: 251-276
  • 10 Fercher A. Verfahren und Anordnung zur Messung der Teilstrecken des lebenden Auges. Offenlegungsschrift DE 3201801 A1; Anmeldetag 21.01.1982, Offenlegungstag 08.09.1983. . Deutschland Patent DE 3201801 A1, 08 09 1983
  • 11 Fercher A, Roth E. Ophthalmic Laser Interferometry. Proc SPIE 1986; 658: 48-51
  • 12 Fercher AF, Mengedoht K, Werner W. Eye-length measurement by interferometry with partially coherent light. Opt Lett 1988; 13: 186-188
  • 13 Hitzenberger CK. Adolf Friedrich Fercher: a pioneer of biomedical optics. J Biomed Opt 2017; 22: 1-8
  • 14 Fercher A. Ophthalmic interferometry. In: von Bally G, Khanna S, eds. Proceedings of the International Conference on Optics in Life Sciences, 12 – 16 August 1990 Garmisch-Partenkirchen: 221-228
  • 15 Fercher AF, Hitzenberger CK, Drexler W. et al. In vivo optical coherence tomography. Am J Ophthalmol 1993; 116: 113-114
  • 16 Haigis W. ULIB: User Group for Laser Interference Biometry. Last Revision: Oct 31; 2016. http://ocusoft.de/ulib/c1.htm Accessed: 11.08.2024
  • 17 Haigis W. Influence of axial length on IOL constants. Acta Clin Croat 2012; 51 (Suppl. 1) 59-64
  • 18 Hoffer K. Acknowledgements. In: Aramberri J, Hoffer KJ, Olsen T, Savini G, Shammas HJ. (Editors) Intraocular Lens Calculations. Cham: Springer; 2024
  • 19 Scholtz S, Schwemm M, Eppig T. et al. Benefits and New Features of a Modern International Internet Database „IOLCon“ for Updated and Optimized IOL Constants and IOL Specifications. Klin Monbl Augenheilkd 2021; 238: 996-1003
  • 20 Guthoff RF, Stachs O. Nachruf Prof. Dr. rer. nat. Wolfgang Haigis. Klin Monbl Augenheilkd 2020; 237: 8
  • 21 Haigis W. IOL calculation according to HAIGIS. http://ocusoft.de/serv/ioltxt/haie.htm Accessed: 12.08.2024