Dtsch Med Wochenschr 2007; 132: e69-e73
DOI: 10.1055/s-2007-959047
Statistik | Statistics

© Georg Thieme Verlag KG Stuttgart · New York

Vergleich von Messmethoden

- Artikel Nr. 24 der Statistik-Serie in der DMW -Comparing methods of measurementU. Grouven1 , R. Bender1 , A. Ziegler2 , S. Lange1
  • 1Institut für Qualität und Wirtschaftlichkeit im Gesundheitswesen, Köln
  • 2Institut für Medizinische Biometrie und Statistik, Universitätsklinikum Schleswig-Holstein, Campus Lübeck, Universität zu Lübeck
Weitere Informationen

Publikationsverlauf

Publikationsdatum:
25. Mai 2007 (online)

Literatur

  • 1 Grouven U, Bender R, Ziegler A, Lange S. Der Kappa-Koeffizient.  Dtsch Med Wochenschr. 2007;  132 e65-e68
  • 2 Bland J M, Altman D G. Measuring agreement in method comparison studies.  Stat Meth Med Res. 1999;  8 135-160
  • 3 Lin L I. A concordance correlation coefficient to evaluate reproducibility.  Biometrics. 1989;  45 255-268
  • 4 Atkinson G, Nevill A. Comment on the use of concordance correlation to assess the agreement between two variables.  Biometrics. 1997;  53 775-777
  • 5 Bland J M, Altman D G. Applying the right statistics: analyses of measurement studies.  Ultrasound Obstet Gynecol. 2003;  22 85-93
  • 6 Müller R, Büttner P. A critical discussion of intraclass correlation coefficients.  Stat Med. 1994;  13 2465-2476
  • 7 Bland J M, Altman D G. A note on the use of the intraclass correlation coefficient in the evaluation of agreement between two methods of measurement.  Comput Biol Med. 1990;  20 337-340
  • 8 Bartko J J. Measures of agreement: a single procedure.  Stat Med. 1994;  13 737-745
  • 9 Fleiss J L, Levin B, Paik M C. Statistical Methods for Rates and Proportions. Third edition. Wiley 2003
  • 10 Bland J M, Altman D G. Statistical methods for assessing agreement between two methods of clinical measurement.  Lancet. 1986;  i 307-310
  • 11 Bland J M, Altman D G. Comparing methods of measurement: why plotting difference against standard method is misleading.  Lancet. 1995;  346 1085-1087
  • 12 Bahmaie A, Hughes S W, Clark T. et al . Serial fetal lung volume measurement using three-dimensional ultrasound.  Ultrasound Obstet Gynecol. 2000;  16 154-158
  • 13 Ryan T P, Woodall W H. The most-cited statistical papers.  J Appl Stat. 2005;  32 461-474

Privatdozent Dr. rer. biol. hum. Ralf Bender

Institut für Qualität und Wirtschaftlichkeit im Gesundheitswesen (IQWiG)

Dillenburger Straße 27

51105 Köln

eMail: Ralf.Bender@iqwig.de

    >