CC BY-NC-ND 4.0 · Rev Bras Ortop (Sao Paulo) 2019; 54(01): 087-089
DOI: 10.1016/j.rbo.2017.06.021
Case Report | Relato de Caso
Sociedade Brasileira de Ortopedia e Traumatologia. Published by Thieme Revnter Publicações Ltda Rio de Janeiro, Brazil

Pseudotumor em artroplastia total do quadril metal-metal com cabeça de grande diâmetro[*]

Artikel in mehreren Sprachen: português | English
1   Universidade Federal de Juiz de Fora (UFJF), Hospital Universitário, Juiz de Fora, Brasil
,
Daniel Naya Loures
2   Universidade de São Paulo (USP), Hospital das Clinicas, Ribeirão Preto, Brasil
,
Armando D'Lucca de Castro e Silva
1   Universidade Federal de Juiz de Fora (UFJF), Hospital Universitário, Juiz de Fora, Brasil
,
Luiz Fernando Ribeiro Monte
1   Universidade Federal de Juiz de Fora (UFJF), Hospital Universitário, Juiz de Fora, Brasil
› Institutsangaben
Weitere Informationen

Publikationsverlauf

11. April 2017

06. Juni 2017

Publikationsdatum:
01. März 2019 (online)

Resumo

Os autores descrevem caso de artroplastia total do quadril (ATQ) com par tribológico metal-metal e cabeça de grande diâmetro que evoluiu com formação de pseudotumor inflamatório. O diagnóstico foi estabelecido por ressonância magnética com supressão de artefato metálico. O tratamento consistiu na ressecção do tecido anormal e revisão com par tribológico cerâmica-polietileno reticulado. Nenhum caso semelhante em língua portuguesa encontra-se descrito nas bases de dados PubMed, Scielo e Lilacs até a presente data.

* Trabalho desenvolvido no Hospital Universitário, Universidade Federal de Juiz de Fora (UFJF), e Hospital Albert Sabin, Juiz de Fora, MG, Brasil. Publicado originalmente por Elsevier Editora Ltda. © 2018 Sociedade Brasileira de Ortopedia e Traumatologia.


 
  • Referências

  • 1 Bozic KJ, Kurtz S, Lau E, Ong K, Chiu V, Vail TP. , et al. The epidemiology of bearing surface usage in total hip arthroplasty in the United States. J Bone Joint Surg Am 2009; 91 (07) 1614-20
  • 2 Bosker BH, Ettema HB, van Rossum M, Boomsma MF, Kollen BJ, Maas M. , et al. Pseudotumor formation and serum ions after large head metal-on-metal stemmed total hip replacement. Risk factors, time course and revisions in 706 hips. Arch Orthop Trauma Surg 2015; 135 (03) 417-25
  • 3 Fricka KB, Ho H, Peace WJ, Engh Jr CA. Metal-on-metal local tissue reaction is associated with corrosion of the head taper junction. J Arthroplasty 2012; 27 (8, Suppl) 26-31.e1
  • 4 Kop AM, Swarts E. Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases. J Arthroplasty 2009; 24 (07) 1019-23
  • 5 Cooper HJ, Della Valle CJ, Berger RA, Tetreault M, Paprosky WG, Sporer SM. , et al. Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am 2012; 94 (18) 1655-61
  • 6 Fagotti L, Vicente JR, Miyahara HS, de Oliveira PV, Bernabé AC, Croci AT. Formation of a pseudotumor in total hip arthroplasty using a tribological metal-polyethylene pair. Rev Bras Ortop 2015; 50 (06) 747-51
  • 7 Scully WF, Teeny SM. Pseudotumor associated with metal-on-polyethylene total hip arthroplasty. Orthopedics 2013; 36 (05) e666-70
  • 8 Berry DJ, Callaghan JJ, Barrack RL, Bostrom MP, Browne JA, Greenwald AS. , et al. Trunions, Tapers, and Corrosion in Total Hip Arthroplasty: What's All the Fuss About? What Every Surgeon Should Know. In: AAOS 2015 Annual Meeting –Instructional Course #301 Lecture Handout 2015
  • 9 Langton DJ, Sidaginamale R, Lord JK, Nargol AVF, Joyce TJ. Taper junction failure in large-diameter metal-on-metal bearings. Bone Joint Res 2012; 1 (04) 56-63
  • 10 Kwon YM, Lombardi AV, Jacobs JJ, Fehring TK, Lewis CG, Cabanela ME. Risk stratification algorithm for management of patients with metal-on-metal hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and the Hip Society. J Bone Joint Surg Am 2014; 96 (01) e4