Thromb Haemost 2007; 97(04): 675-676
DOI: 10.1160/TH06-11-0664
Letters to the Editor
Schattauer GmbH

Haemophilia patients exhibit prolonged coagulation time but normal lag time of thrombin generation test: Are these results really discordant?

Yesim Dargaud
1   Laboratoire d’Hémostase, Hopital Edouard Herriot, Lyon, France
2   Unite d’Hemostase Clinique, Hopital Edouard Herriot, Lyon, France
,
Jean Claude Bordet
1   Laboratoire d’Hémostase, Hopital Edouard Herriot, Lyon, France
,
Stéphanie Francillon
1   Laboratoire d’Hémostase, Hopital Edouard Herriot, Lyon, France
,
Claude Négrier
1   Laboratoire d’Hémostase, Hopital Edouard Herriot, Lyon, France
2   Unite d’Hemostase Clinique, Hopital Edouard Herriot, Lyon, France
› Author Affiliations
Further Information

Publication History

Received 25 November 2006

Accepted after revision 16 January 2007

Publication Date:
24 November 2017 (online)

 

 
  • References

  • 1 Luddington RL. Thromboelastography, thromboelastometry. Clin Lab Haem 2005; 27: 81-90.
  • 2 Sorensen B, Ingerslev J. Whole blood clot formation phenotypes in haemophilia A and rare coagulation disorders. Patterns of response to recombinant factor VIIa. J Thromb Haemost 2004; 2: 102-110.
  • 3 Hemker HC, Giesen P, Al Dieri R. et al. Calibrated automated thrombin generation measurement in clotting plasma. Pathophysiol Haemost Thromb 2003; 33: 4-15.
  • 4 Dargaud Y, Beguin S, Lienhart A. et al. Evaluation of thrombin generating capacity in plasma from patients with haemophilia A and B. Thromb Haemost 2005; 93: 475-480.
  • 5 Beltran-Miranda CP, Khan A, Jaloma-Cruz AR. et al. Thrombin generation and phenotypic correlation in haemophilia A. Haemophilia 2005; 11: 326-334.