Minim Invasive Neurosurg 2000; 43(2): 72-74
DOI: 10.1055/s-2000-8322
ÜBERSICHT
Georg Thieme Verlag Stuttgart · New York

Ultrasonic Contact Microprobe: Experimental Results

J. Paladino1 , D. Štimac1 , K. Rotim1 , N. Pirker1 , A. Štimac2
  • 1 Department of Neurosurgery, School of Medicine, University of Zagreb, Kispaticeva 12, 10 000 Zagreb, Croatia
  • 2 Measurement, Vibrations and Acoustics Department, Brodarski Institute, Av. Veceslava Holjevca 20, 10 000 Zagreb, Croatia
Further Information

Publication History

Publication Date:
31 December 2000 (online)

At the Department of Neurosurgery, School of Medicine, University of Zagreb, the original ultrasonic contact microprobe (UCM) was designed. The efficacy of the instrument was tested on 120 brains of Wistar strain rats. The authors have been investigating the possibility of transferring high-energy ultrasound through the titanium wire probe of the device and the efficacy of UCM in controlled punctiform destruction of brain tissue. Light and electron microscope assessed the lesions made in the brains of experimental rats. Histological findings in the preparations showed the zone of thermal injuries from 100 to 200 µm and the zone of ultrastructural changes from 200 to 300 µm, indicating the sparing effect of the microprobe with regard to the adjacent neurovascular structures. The small dimensions of the ultrasonic contact microprobe (1.6 mm) enable its introduction through the operating canal of a ventriculoscope. Further research is expected to show the efficacy of the ultrasonic contact microprobe in endoscopic neurosurgery.

References

  • 1 Bond L J, Cimino W W. Physics of ultrasonic surgery using tissue fragmentation.  Ultrasonics. 1996;  34 579-585
  • 2 Bond L J, Cimino W W. Physics of ultrasonic surgery using tissue fragmentation: Part II.  Ultrasound Med Biol. 1996;  22 101-117
  • 3 Cimino W W, Bond L J. Physics of ultrasonic surgery using tissue fragmentation: Part I.  Ultrasound Med Biol. 1996;  22 89-100
  • 4 Goss S A, Frizzell L A, Dunn F. Ultrasonic absorption and attenuation in mammalian tissues.  Ultrasound Med Biol. 1979;  5 181-186
  • 5 Kehler U, Gliemorth J, Knopp U, Arnold H. How to perforate safely a resistant floor of the 3rd ventricle. Technical note.  Minim Invas Neurosurg. 1998;  41 198-199
  • 6 Mueller W, Fritzch G. Medicotechnical basics of surgery using invasive ultrasonic energy.  Endoscop Surg Allied Technol. 1994;  2 205-210
  • 7 Perneczky A, Fries G. Endoscope-assisted brain surgery: Part I - evolution, basic concept and current technique.  Neurosurgery. 1998;  42 219-224
  • 8 Schurr O, Werman M, Kunert W. Histological effect of different technologies for dissection in endoscopic surgery: Nd:YAG laser, high frequency electrocauter and water-jet.  Endoscop Allied Technol. 1994;  2 195-201

Corresponding Author:

K RotimM.D., M.Sc 

Department of Neurosurgery Clinical Hospital Centar Zagreb

Kispaticeva 12 10 000 Zagreb, Croatia

Phone: Tel. & Fax: ++385 1 2333 196

Email: E-mail: nrk-kbc@zg.tel.hr

    >