J Wrist Surg 2017; 06(02): 163-169
DOI: 10.1055/s-0036-1593763
Procedure
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Surgical Strategy and Techniques for Low-Profile Dorsal Plating in Treating Dorsally Displaced Unstable Distal Radius Fractures

Yoshitaka Hamada
1   Department of Orthopedic Surgery, Osaka Hospital, Osaka, Japan
,
Hiroyuki Gotani
1   Department of Orthopedic Surgery, Osaka Hospital, Osaka, Japan
,
Naohito Hibino
2   Hand Center, Health Insurance Naruto Hospital, Tokushima, Japan
,
Yoshitaka Tanaka
1   Department of Orthopedic Surgery, Osaka Hospital, Osaka, Japan
,
Ryousuke Satoh
2   Hand Center, Health Insurance Naruto Hospital, Tokushima, Japan
,
Kousuke Sasaki
1   Department of Orthopedic Surgery, Osaka Hospital, Osaka, Japan
,
Thepparat Kanchanathepsak
3   Hand and Microsurgery Unit, Department of Orthopedics, Mahidol University, Salaya, Thailand
› Author Affiliations
Further Information

Publication History

05 August 2016

14 September 2016

Publication Date:
19 October 2016 (online)

Abstract

Background The low-profile dorsal locking plating (DLP) technique is useful for treating dorsally comminuted intra-articular distal radius fractures; however, due to the complications associated with DLP, the technique is not widely used.

Methods A retrospective review of 24 consecutive cases treated with DLP were done.

Results All cases were classified into two types by surgical strategy according to the fracture pattern. In type 1, there is a volar fracture line distal to the watershed line in the dorsally displaced fragment, and this type is treated by H-framed DLP. In type 2, the displaced dorsal die-punch fragment is associated with a minimally displaced styloid shearing fracture or a transverse volar fracture line. We found that the die-punch fragment was reduced by the buttress effect of small l-shaped DLP after stabilization of the styloid shearing for the volar segment by cannulated screws from radial styloid processes. At 6 months after surgery, outcomes were good or excellent based on the modified Mayo wrist scores with no serious complications except one case. The mean range of motion of each type was as follows: the palmar flexion was 50, 65 degrees, dorsiflexion was 70, 75 degrees, supination was 85, 85 degrees, and pronation was 80, 80 degrees; in type 1 and 2, respectively.

Conclusion DLP is a useful technique for the treatment of selected cases of dorsally displaced, comminuted intra-articular fractures of the distal radius with careful soft tissue coverage.

Note

No benefits in any form have been received or will be received from a commercial party related directly or indirectly to the subject of this article. No funds were received in support of this study.


 
  • References

  • 1 Earp BE, Foster B, Blazar PE. The use of a single volar locking plate for AO C3-type distal radius fractures. Hand (NY) 2015; 10 (4) 649-653
  • 2 Fok MW, Klausmeyer MA, Fernandez DL, Orbay JL, Bergada AL. Volar plate fixation of intra-articular distal radius fractures: a retrospective study. J Wrist Surg 2013; 2 (3) 247-254
  • 3 Wichlas F, Haas NP, Disch A, Machó D, Tsitsilonis S. Complication rates and reduction potential of palmar versus dorsal locking plate osteosynthesis for the treatment of distal radius fractures. J Orthop Traumatol 2014; 15 (4) 259-264
  • 4 Dy CJ, Wolfe SW, Jupiter JB, Blazar PE, Ruch DS, Hanel DP. Distal radius fractures: strategic alternatives to volar plate fixation. Instr Course Lect 2014; 63: 27-37
  • 5 Tyllianakis ME, Panagopoulos AM, Saridis A. Long-term results of dorsally displaced distal radius fractures treated with the pi-plate: is hardware removal necessary?. Orthopedics 2011; 34 (7) e282-e286
  • 6 Gajdos R, Bozik M, Stranak P. Is an implant removal after dorsal plating of distal radius fracture always needed?. Bratisl Lek Listy (Tlacene Vyd) 2015; 116 (6) 357-362
  • 7 Yu YR, Makhni MC, Tabrizi S, Rozental TD, Mundanthanam G, Day CS. Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study. J Hand Surg Am 2011; 36 (7) 1135-1141
  • 8 Matzon JL, Kenniston J, Beredjiklian PK. Hardware-related complications after dorsal plating for displaced distal radius fractures. Orthopedics 2014; 37 (11) e978-e982
  • 9 Lutsky K, McKeon K, Goldfarb C, Boyer M. Dorsal fixation of intra-articular distal radius fractures using 2.4-mm locking plates. Tech Hand Up Extrem Surg 2009; 13 (4) 187-196
  • 10 Lutsky K, Boyer M, Goldfarb C. Dorsal locked plate fixation of distal radius fractures. J Hand Surg Am 2013; 38 (7) 1414-1422
  • 11 Kiyoshige Y. Condylar stabilizing technique with AO/ASIF distal radius plate for Colles' fracture associated with osteoporosis. Tech Hand Up Extrem Surg 2002; 6 (4) 205-208
  • 12 Tavakolian JD, Jupiter JB. Dorsal plating for distal radius fractures. Hand Clin 2005; 21 (3) 341-346
  • 13 Jupiter JB. Complex articular fractures of the distal radius: classification and management. J Am Acad Orthop Surg 1997; 5 (3) 119-129
  • 14 Zenke Y, Sakai A, Oshige T , et al. Extensor pollicis longus tendon ruptures after the use of volar locking plates for distal radius fractures. Hand Surg 2013; 18 (2) 169-173
  • 15 Matschke S, Wentzensen A, Ring D, Marent-Huber M, Audigé L, Jupiter JB. Comparison of angle stable plate fixation approaches for distal radius fractures. Injury 2011; 42 (4) 385-392
  • 16 Kim JK, Cho SW. The effects of a displaced dorsal rim fracture on outcomes after volar plate fixation of a distal radius fracture. Injury 2012; 43 (2) 143-146
  • 17 Horst TA, Jupiter JB. Stabilisation of distal radius fractures: Lessons learned and future directions. Injury 2016; 47 (2) 313-319
  • 18 Rikli DA, Regazzoni P. The double plating technique for distal radius fractures. Tech Hand Up Extrem Surg 2000; 4 (2) 107-114
  • 19 Rikli DA, Regazzoni P, Babst R. Management of complex distal radius fractures [in German]. Zentralbl Chir 2003; 128 (12) 1008-1013
  • 20 Medoff RJ. Essential radiographic evaluation for distal radius fractures. Hand Clin 2005; 21 (3) 279-288
  • 21 Benson LS, Minihane KP, Stern LD, Eller E, Seshadri R. The outcome of intra-articular distal radius fractures treated with fragment-specific fixation. J Hand Surg Am 2006; 31 (8) 1333-1339
  • 22 Geissler WB. Management distal radius and distal ulnar fractures with fragment specific plate. J Wrist Surg 2013; 2 (2) 190-194
  • 23 Brogan DM, Richard MJ, Ruch D, Kakar S. Management of severely comminuted distal radius fractures. J Hand Surg Am 2015; 40 (9) 1905-1914