In expert hands, bile duct access using endoscopic retrograde cholangiopancreatography
(ERCP) is almost always successful [1]. Nevertheless, to achieve deep common bile duct (CBD) cannulation, a great variety
of techniques and devices must sometimes be employed by the biliary endoscopist [2]. A hidden papilla within a duodenal diverticulum is sometimes challenging. A case
is presented here in which two special techniques of bile duct cannulation were used
([Video 1]).
Video 1 Papilla located in the left edge of a duodenal diverticulum but completely hidden.
Two devices were employed. A cannula served to evert the papillary orifice and a sphincterotome
with a guide wire was used to cannulate. Initially, the guide wire entered the pancreatic
duct and was left there. Cannulation above it succeeded in gaining access to the bile
duct.
An 83-year-old woman was admitted because of jaundice. Magnetic resonance cholangiography
showed dilation of the CBD duct secondary to a possible stricture in the distal CBD.
An ERCP was carried out with a therapeutic duodenoscope. The usual papillary location
in the second duodenal portion was occupied by a diverticulum. In its left edge (in
the endoscopic view), the papillary frenulum could be identified, although the papilla
itself was completely hidden within the diverticulum. To evert the papillary orifice,
two devices were employed simultaneously through the working channel [3]. A cannula (Glotip, Cook Medical, Winston-Salem, North Carolina, USA) served to
maintain the papillary orifice out of the diverticulum, and a sphincterotome loaded
with a 0.025 inch hydrophilic guide wire (Tapertome, Boston Scientific, Natick, Massachusetts,
USA) was used to cannulate ([Fig. 1]). Initially, the guide wire entered the pancreatic duct. The guide wire was left
in place there while the sphincterotome was withdrawn. A new attempt to cannulate
above the previously placed pancreatic guide wire succeeded in gaining access to the
bile duct [4]
[5].
Fig. 1 To evert the papillary orifice outside the diverticulum, two devices were employed
simultaneously through the working channel. The black tip of a cannula, which served
to maintain the papillary orifice everted, is seen at the bottom of the image. A sphincterotome
loaded with a 0.025 inch hydrophilic guide wire was used to cannulate the papilla.
The CBD dilation was probably secondary to papillitis or to impaired bile duct flow,
due to the distorted position of the distal CBD in the diverticulum. A biliary sphincterotomy
was performed. There were no complications.
This case can illustrate that, apart from a long learning curve [6], ERCP endoscopists have to perform the procedure frequently in order to be able
to respond quickly enough to the multiple challenges that every single ERCP can present.