Zentralbl Chir 2001; 126(2): 115-121
DOI: 10.1055/s-2001-12420
Originalarbeiten und Übersichten

J.A.Barth Verlag in Medizinverlage Heidelberg GmbH & Co.KG

Ergebnisse und Komplikationen nach endovaskulärer Therapie des Aortenaneurysmas

Results and complications after endovascular treatment of aortic aneurysmR. I. Rückert1 , M. Walter1 , P. Romaniuk2 , G. Löhr1 , J. M. Müller1
  • 1Klinik für Allgemein-, Gefäß-, Thorax- und Viszeralchirurgie (Direktor: Prof. Dr. J.M. Müller), Universitätsklinikum Charité der Humboldt-Universität zu Berlin, Campus Mitte
  • 2Institut für Radiologie (Direktor: Prof. Dr. B. Hamm), Universitätsklinikum Charité der Humboldt-Universität zu Berlin, Campus Mitte
Further Information

Publication History

Publication Date:
31 December 2001 (online)

Results and complications after endovascular treatment of aortic aneurysm

Summary

Introduction: Endovascular repair (ER) has been established as an alternative treatment option for aortic aneurysm (AA) in case of a suitable morphology. However, there are specific problems related to diagnostic and therapeutic management including potential complications of the new procedure. Patients and methods: Between 8/1996 and 11/1999, 41 patients (6 female, mean age 67.9 (range 55-84) years) underwent an operation with the intention of ER. Modular, self-expanding stent-grafts were used for aorto-biiliacal (36), aorto-monoiliacal (1), and aorto-aortal (infrarenal-1, thoracic-1) aortic aneurysm (AA) exclusion. Postoperatively and during the follow-up period, diagnostic measures included clinical investigation, native X-ray, and color-coded Doppler sonography, and spiral computed tomography, and digital subtraction angiography. Results were analysed with special reference to complications and resulting therapeutic consequences. Results: Technical success was achieved in 36/41 patients (87.8 %). There were 2 primary distal endoleaks and 3 conversions because of lacking vascular access. Of 4 primary endoleaks, a proximal one was treated successfully by overstenting, a distal one was sealed off by iliac extension, and 2 distal ones were treated conservatively. Three secondary endoleaks, a proximal and 2 distal ones, required conversion each by retro- and transperitoneal approach. Presently, there are 4 endoleaks, with the maximal aortic diameter remaining constant except one case. Five secondary occlusions of an iliac limb (4) or artery (1) were treated by thrombectomy (1), PTA (1), PTA with overstenting (1), and cross-over (1) or ilicofemoral bypass (1). Three patients died of unrelated disease during the follow-up period. Discussion: On condition of a critical indication, improved diagnostic management and further refinement of stent-graft systems ER constitutes an alternative, minimally invasive treatment option for AA. Long-term results must be obtained by means of continued prospective and comparative studies to definitely evaluate ER.

Zusammenfassung

Einleitung: Die endovaskuläre Stentprothesenimplantation (EVS) ist bei geeigneter Morphologie als alternative Methode zur Ausschaltung von Aortenaneurysmen (AA) etabliert, jedoch bestehen spezifische Probleme der Diagnostik und der Therapie einschließlich möglicher Komplikationen dieses neuen Verfahrens. Methodik: Von 8/1996 bis 11/1999 wurden in einer prospektiven Studie bisher 41 Patienten (6 weiblich, mittleres Alter 67,9 (55-84) Jahre) mit dem Ziel der EVS eines AA behandelt. Es wurden modulare, selbstexpandierende Stentprothesensysteme aorto-biiliakal (36), aorto-monoiliakal (1) und aorto-aortal (infrarenal-1, thorakal-1) implantiert. Die Kontrolldiagnostik erfolgte in definierten Zeitintervallen klinisch, mittels nativer Röntgendiagnostik, farbkodierter Duplexsonographie, Spiral-Computertomographie und digitaler Subtraktionsangiographie. Die Ergebnisse wurden unter besonderer Berücksichtigung der Komplikationen und daraus entstehender therapeutischer Konsequenzen analysiert. Ergebnisse: Bei 36/41 Patienten (87,8 %) war die EVS des AA technisch erfolgreich (2 primäre distale Endoleaks, 3 Konversionen wegen ungeeignetem iliakalem Zugang). Von 4 primären Endoleaks wurden 1 proximales durch „overstenting”, 1 distales durch iliakale Verlängerung und 2 konservativ behandelt. Ein sekundäres proximales und zwei sekundäre distale Endoleaks erforderten die Konversion mittels retro- bzw. transperitonealer AA-Ausschaltung. Derzeit bestehen 4 distale Endoleaks, wobei der maximale Aortendurchmesser bis auf einen Fall konstant blieb. Vier sekundäre iliakale Prothesenschenkelverschlüsse oder -stenosen sowie ein Beckenarterienverschluß wurden durch Thrombektomie (1), PTA (1), PTA mit „overstenting” (1) und ,,cross-over" (1) oder ilikofemoralen Bypass (1) behandelt. Drei Patienten verstarben postoperativ ohne Zusammenhang mit der EVS. Bei einem Follow-up von 3 bis 39 (median 30) Monaten sind derzeit 28/32 Patienten komplikationsfrei. Schlußfolgerungen: Bei kritischer Indikationsstellung, weiterer Qualifikation der Diagnostik zur genauen morphologischen Planung und technischer Vervollkommnung der Stentprothesensysteme bildet die EVS eine alternative, minimal-invasive Therapieoption für AA. Durch Fortführung prospektiver und vergleichender Studien müssen Langzeitergebnisse mit dem Ziel der definitiven Bewertung der EVS erhalten werden.

Literatur

  • 1 Ahn S, Rutherford R B, Johnston K W. et al . Reporting standards for infrarenal endovascular abdominal aneurysm repair.  J Vasc Surg. 1997;  25 405-413
  • 2 Becquemin J P, Lapie V, Favre J P, Rousseau H.. for the French Vanguard Study Group . Mid-term results of a second generation bifurcated endovascular Graft for abdominal aortic aneurysm repair: The French Vanguard trial.  J Vasc Surg. 1999;  30 209-218
  • 3 Blum U, Voshage G, Lammer J. et al . Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms.  N Engl J Med. 1997;  336 13-20
  • 4 Boyle J R, Thompson J P, Thompson M M, Sayers R D, Smith G, Bell P R F. Improved respiratory function and analgesia control after endovascular AAA repair.  J Endovasc Surg. 1997;  4 62-65
  • 5 Buth J, Laheij R J F,. on behalf of the EUROSTAR Collaborators . Early complications and endoleaks after endovascular abdominal aortic aneurysm repair: Report of a multicanter study.  J Vasc Surg. 2000;  31 134-146
  • 6 Chuter T A M, Reilly L M, Faruqi R M, Kerlan R B, Sawhney R, Canto C J, LaBerge J M, Wilson M W, Gordonv R L, Wall S D, Rapp J, Messina L M. Endovascular aneurysm repair in high-risk patients.  J Vasc Surg. 2000;  31 122-133
  • 7 Dake M D, Kato N, Mitchell R S, Semba C P, Razavi M K, Shimono T, Hirano T, Takeda K, Yada I, Miller D C. Endovascular stent-graft placement for the treatment of acute aortic dissection.  N Engl J Med. 1999;  340 1546-1552
  • 8 Gilling-Smith G, Brennan J, Harris P, Bakran A, Gould D, McWilliams R. Endotension after endovascular aneurysm repair: Definition, classification, and strategies for surveillance and intervention.  J Endovasc Surg. 1999;  6 305-307
  • 9 Greenberg R K, Srivastava S D, Ouriel K, Waldman D, Ivancev K, Illig K A, Shortell C, Green R M. An endoluminal method of hemorrhage control and repair of ruptured abdominal aortic aneurysms.  J Endovsc Ther. 2000;  7 1-7
  • 10 Inoue K, Iwase T, Sato M. et al . Transluminal endovascular branched graft placement for a pseudoaneurysm: reconstruction of the descending thoracic aorta including the celiac axis.  J Thorac Cardiovasc Surg. 1997;  114 859
  • 11 Moore W S, Kashyap V S, Vescera C L, Quinones-Baldrich W J. Abdominal aortic aneurysm. A 6-year comparison of endovascular versus transabdominal repair.  Ann Surg. 1999;  230 298-308
  • 12 Nienaber C A, Fattori R, Lund G, Dieckmann C, Wolf W, von Kodolitsch Y, Nicolas V, Pierangeli A. Nonsurgical reconstruction of thoracic aortic dissection by stent.graft placement.  New Engl J Med. 1999;  340 1539-1545
  • 13 Ohki T, Veith F J, Sanchez L A, Cynamon J, Lipsitz E C, Wain R A, Morgan J A, Zhen L, Suggs W D, Lyon R T. Endovascular graft repair of ruptured aortoiliac aneurysms.  J Am Coll Surg. 1999;  189 102-113
  • 14 Parodi J C, Palmaz J C, Barone H D. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms.  Ann Vasc Surg. 1991;  5 491-499
  • 15 Riepe G, Heintz C, ChafkÅ N, Morlock M, Gross-Fengels W, Imig H. Stentdrahtbrüche und Maschenlockerungen explantierter, endovaskulärer Prothesen.  Zentralbl Chir. 2000;  125 22-26
  • 16 Rückert R I, Romaniuk P, Rogalla P, Umscheid T, Stelter W J, Müller J M. A method for adjustment of a malpositioned bifurcated endovascular stent-graft.  J Endovasc Surg. 1998;  4 261-265
  • 17 Rückert R I, Romaniuk P, Rogalla P, Thieme T, Umscheid T, Stelter W J, Müller J M. Combined surgical and endovascular thrombus removal from an occluded bifurcated aortic stent-graft.  J Endovasc Surg. 1998;  5 323-328
  • 18 Sato D T, Goff C D, Gregory R T, Robinson K D, Carter K A, Herts B R, Vilsack H B, Gayle R G, Parent N, DeMasi R J, Meier G H. Endoleak after aortic stent graft repair: Diagnosis by color duplex ultrasound scan versus computed tomography scan.  J Vasc Surg. 1998;  28 657-663
  • 19 Stelter W J, Umscheid T, Ziegler P. Three years surgical experience with modular stentgraft devices for treatment of AAA.  J Endovasc Surg. 1997;  4 362-369
  • 20 Treharne G D, Thompson M M, Whiteley M S, Bell P R F. Physiological comparison of open and endovascular aneurysm repair.  Br J Surg. 1999;  86 760-764
  • 21 Umscheid T, Stelter W J, Ziegler P. Mittelfristige Komplikationen und Probleme nach endovaskulären Aortenstentprothesen.  Zentralbl Chir. 2000;  125 7-14
  • 22 Van Essen J A, Gussenhoven E J, van der Lugt A, Huijsman P C, van Muiswinkel M R, van Sambeck H M, van Dijk L C, van Urk H. Accurate assessment of abdominal aortic aneurysm with intravascular ultrasound scanning: validation with computed tomographic angiography.  J Vasc Surg. 1999;  29 631-638
  • 23 Virgilio C, Bui H, Donayre C, Ephraim L, Lewis R J, Elbassir M, Stabile B E, White R. Endovascular vs open abdominal aortic aneurysm repair.  Arch Surg. 1999;  134 947-951
  • 24 Volodos N L, Karpovich I P, Troyan V I, Kalashnikova Yu V, Shekhanin V E, Ternyuk N E, Neoneta A S, Ustinov N I, Yakovenko L F. Clinical experience of the use of self-fixing synthetic prostheses for remote endoprosthetics of the thoracic aorta and the abdominal aorta and iliac arteries through the femoral artery and as intraoperative endoprosthesis for aorta reconstruction.  Vasa Suppl. 1991;  33 93-95
  • 25 Walker S R, Macierewicz J, Elmarasy N M, Gregson R H S, Whitaker S C, Hopkinson B R. A prospective study to assess changes in proximal aortic neck dimensions after endovascular repair of abdominal aortic aneurysms.  J Vasc Surg. 1999;  29 625-630
  • 26 White G H, Yu W, May J. et al . Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: Classification, incidence, diagnosis, and management.  J Endovasc Surg. 1997;  4 152-168
  • 27 White G H, May J, Petrasek P, Waugh R, Stephen M, Harris J. Endotension: An explanation for continued AAA growth after successful endoluminal repair.  J Endovasc Surg. 1999;  6 308-315
  • 28 Zarins C K, White R A, Schwarten D, Kinney E, Diethrich E B, Hodgson K J, Fogarty T J,. for the investigators of the Medtronic AneuRx Multicenter Clinical Trial . AneuRx stent graft versus open surgical repair of abdominal aortic aneurysms: Multicenter prospective clinical trial.  J Vasc Surg. 1999;  29 292-308

Dr. R. I. Rückert

Klinik für Allgemein-, Gefäß-, Thorax- und Viszeralchirurgie
Universitätsklinikum Charité
der Humboldt-Universität zu Berlin
Campus Mitte

Schumannstraße 20/21

D-10117 Berlin

Phone: Tel.: 0 30/28 02-50 70

Fax: Fax: 0 30/28 02-49 62

Email: E-mail: ralph-i.rueckert@charite.de

    >