Thorac Cardiovasc Surg 2022; 70(08): 684-686
DOI: 10.1055/s-0042-1744263
Short Communication

Safe Technique of Coronary Button Preparation in Redo Bentall Operation

1   Division of Cardiothoracic Surgery, Department of Surgery, Westchester Medical Center, New York Medical College, Valhalla, New York, United States
,
Ramin Malekan
1   Division of Cardiothoracic Surgery, Department of Surgery, Westchester Medical Center, New York Medical College, Valhalla, New York, United States
,
Masashi Kai
1   Division of Cardiothoracic Surgery, Department of Surgery, Westchester Medical Center, New York Medical College, Valhalla, New York, United States
,
David Spielvogel
1   Division of Cardiothoracic Surgery, Department of Surgery, Westchester Medical Center, New York Medical College, Valhalla, New York, United States
› Author Affiliations

Abstract

We introduce a technique of coronary button reconstruction in performing a redo Bentall procedure. A coronary button is prepared leaving a 3 to 4 mm rim of old Dacron graft surrounding the previous button. The Dacron rim may be sewn to the new aortic root graft directly or via an interposed 8- or 10-mm graft, using a modified Cabrol technique. If the button is comprised of good tissue and can be well-mobilized, it is removed from the Dacron rim and anastomosed directly to the new Dacron graft.



Publication History

Received: 08 December 2021

Accepted: 04 February 2022

Article published online:
19 April 2022

© 2022. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Jassar AS, Desai ND, Kobrin D. et al. Outcomes of aortic root replacement after previous aortic root replacement: the “true” redo root. Ann Thorac Surg 2015; 99 (05) 1601-1608 , discussion 1608–1609
  • 2 Garrido-Olivares L, Maganti M, Armstrong S, David TE. Clinical outcomes of aortic root replacement after previous aortic root replacement. J Thorac Cardiovasc Surg 2013; 146 (03) 611-615
  • 3 Girardi LN. Reoperative repair of aortic root and ascending aorta. Oper Tech Thorac Cardiovasc Surg 2012; 17 (01) P2-14
  • 4 Svensson LG. Approach for insertion of aortic composite valve grafts. Ann Thorac Surg 1992; 54 (02) 376-378
  • 5 Piehler JM, Pluth JR. Replacement of the ascending aorta and aortic valve with a composite graft in patients with nondisplaced coronary ostia. Ann Thorac Surg 1982; 33 (04) 406-409