Int J Sports Med 2016; 37(10): 825-830
DOI: 10.1055/s-0042-108651
Training & Testing
© Georg Thieme Verlag KG Stuttgart · New York

The Reliability of a Pre-Loaded Treadmill Time-Trial in Moderate Normobaric Hypoxia

Authors

  • O. Shannon

    1   Institute for Sport, Physical Activity and Leisure, Leeds Beckett University, Carnegie Faculty, Headingley Campus, Headingley, Leeds, United Kingdom of Great Britain and Northern Ireland
  • M. Barlow

    1   Institute for Sport, Physical Activity and Leisure, Leeds Beckett University, Carnegie Faculty, Headingley Campus, Headingley, Leeds, United Kingdom of Great Britain and Northern Ireland
  • L. Duckworth

    1   Institute for Sport, Physical Activity and Leisure, Leeds Beckett University, Carnegie Faculty, Headingley Campus, Headingley, Leeds, United Kingdom of Great Britain and Northern Ireland
  • D. R. Woods

    1   Institute for Sport, Physical Activity and Leisure, Leeds Beckett University, Carnegie Faculty, Headingley Campus, Headingley, Leeds, United Kingdom of Great Britain and Northern Ireland
    2   Northumbria and Newcastle NHS Trusts, Medicine, Newcastle Upon Tyne, United Kingdom of Great Britain and Northern Ireland
  • T. Barker

    3   Department of Vascular Surgery, Royal Stoke University Hospital, Newcastle Road, Stoke on Trent, United Kingdom of Great Britain and Northern Ireland
  • A. Grindrod

    1   Institute for Sport, Physical Activity and Leisure, Leeds Beckett University, Carnegie Faculty, Headingley Campus, Headingley, Leeds, United Kingdom of Great Britain and Northern Ireland
    2   Northumbria and Newcastle NHS Trusts, Medicine, Newcastle Upon Tyne, United Kingdom of Great Britain and Northern Ireland
  • A. Griffiths

    1   Institute for Sport, Physical Activity and Leisure, Leeds Beckett University, Carnegie Faculty, Headingley Campus, Headingley, Leeds, United Kingdom of Great Britain and Northern Ireland
  • J. P. O’Hara

    1   Institute for Sport, Physical Activity and Leisure, Leeds Beckett University, Carnegie Faculty, Headingley Campus, Headingley, Leeds, United Kingdom of Great Britain and Northern Ireland
Weitere Informationen

Publikationsverlauf



accepted after revision 09. Mai 2016

Publikationsdatum:
23. Juni 2016 (online)

Preview

Abstract

The purpose of this study was to assess the reliability of a pre-loaded 1 500-m treadmill time trial, conducted in moderate normobaric hypoxia. 8 trained runners/triathletes (24±3 years, 73.2±8.1 kg, 182.5±6.5 cm, altitude specific V˙O2max: 52.9±5.5 ml·kg−1·min−1) completed 3 trials (the first as a familiarisation), involving 2, 15-min running bouts at 45% and 65% V˙O2max, respectively, and a 1 500-m time trial in moderate normobaric hypoxia equivalent to a simulated altitude of 2 500 m (FiO2~15%). Heart rate, arterial oxygen saturation, skeletal muscle and cerebral tissue oxygenation (StO2), expired gas ( V˙O2 and V˙CO2), and ratings of perceived exertion were monitored. Running performance (Trial 1: 352.7±40; Trial 2: 353.9±38.2 s) demonstrated a low CV (0.9%) and high ICC (1). All physiological variables demonstrated a global CV≤4.2%, and ICC≥0.87, with the exception of muscle (CV 10.4%; ICC 0.70) and cerebral (CV 4.1%; ICC 0.82) StO2. These data demonstrate good reliability of the majority of physiological variables and indicate that a pre-loaded 1 500-m time trial conducted in moderate normobaric hypoxia is a highly reliable test of performance.