Subscribe to RSS
DOI: 10.1055/s-0041-1724038
Transcatheter Aortic Valve Replacement for a Degenerated Transcatheter Valve—A Single Center Experience

Abstract
Background The transcatheter valve-in-valve treatment (TAV-in-TAV) of degenerated transcatheter aortic valves is becoming more relevant, as the use of transcatheter aortic valve replacement (TAVR) increases. We report our experience with TAV-in-TAV in patients with a degenerated transcatheter heart valve (THV).
Methods We retrospectively analyzed prospectively collected data from our designated TAVR database. Intraprocedural and intrahospital outcomes were reported.
Results Ten patients out of a total of 3,144 TAVR implantations since 2007 presented with a degenerated THV, among those six with an Edwards Sapien XT (Edwards Lifesciences, Irvine, California, United States) valve, treated with a Medtronic Evolut R (Medtronic, Dublin, Ireland) valve. Four patients had severe stenosis, one pure insufficiency, and five combined stenosis and insufficiency. Average time between initial implantation and re-intervention was 6.8 ± 1.3 years. The mean preoperative maximum and mean gradients were 54.2 ± 14.8 mm Hg and 31.6 ± 9.9 mm Hg, respectively. Nine patients underwent transfemoral and one patient underwent transaortic TAV-in-TAV. Mean procedural time was 86.2 ± 51.5 minutes. Post-implantation, the maximum and mean gradients decreased to 18 ± 6.9 mm Hg and 8.4 ± 3.2 mm Hg (16 ± 8 mm Hg and 6.4 ± 1.7 mm Hg in the Evolut-in-Sapien subgroup), respectively. The valve area increased from 0.98 ± 0.28 mm Hg to 1.72 ± 0.32 mm Hg (0.8 ± 0.07 mm Hg to 1.9 ± 0.16 mm Hg in the Evolut-in-Sapien subgroup). Two patients experienced a vascular complication. No further Valve Academic Research Consortium-2 criteria complications occurred during hospitalization.
Conclusion TAV-in-TAV resulted in low procedural and peri-procedural complication rates. In particular, the usage of a supra-annular valve resulted in excellent hemodynamic results. Larger studies are required to validate this observational data and to establish a protocol for this procedure.
Publication History
Received: 25 August 2020
Accepted: 30 December 2020
Article published online:
24 February 2021
© 2021. Thieme. All rights reserved.
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References
- 1
Dvir D,
Webb JG,
Bleiziffer S.
et al;
Valve-in-Valve International Data Registry Investigators.
Transcatheter aortic valve implantation in failed bioprosthetic surgical valves. JAMA
2014; 312 (02) 162-170
MissingFormLabel
- 2 Landes U, Webb JG, De Backer O. et al. Repeat transcatheter aortic valve replacement for transcatheter prosthesis dysfunction. J Am Coll Cardiol 2020; 75 (16) 1882-1893
- 3
Dvir D,
Webb J,
Brecker S.
et al.
Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves:
results from the global valve-in-valve registry. Circulation 2012; 126 (19) 2335-2344
MissingFormLabel
- 4 Webb JG, Dvir D. Transcatheter aortic valve replacement for bioprosthetic aortic valve failure: the valve-in-valve procedure. Circulation 2013; 127 (25) 2542-2550
- 5
Mercanti F,
Rosseel L,
Neylon A.
et al.
Chimney stenting for coronary occlusion during TAVR: insights from the Chimney Registry.
JACC Cardiovasc Interv 2020; 13 (06) 751-761
MissingFormLabel
- 6
Khan JM,
Dvir D,
Greenbaum AB.
et al.
Transcatheter laceration of aortic leaflets to prevent coronary obstruction during
transcatheter aortic valve replacement: concept to first-in-human. JACC Cardiovasc
Interv 2018; 11 (07) 677-689
MissingFormLabel
- 7
Bleiziffer S,
Erlebach M,
Simonato M.
et al.
Incidence, predictors and clinical outcomes of residual stenosis after aortic valve-in-valve.
Heart 2018; 104 (10) 828-834
MissingFormLabel
- 8
Bleiziffer S,
Simonato M,
Webb JG.
et al.
Long-term outcomes after transcatheter aortic valve implantation in failed bioprosthetic
valves. Eur Heart J 2020; 41 (29) 2731-2742
MissingFormLabel
- 9
Webb JG,
Mack MJ,
White JM.
et al.
Transcatheter aortic valve implantation within degenerated aortic surgical bioprostheses:
PARTNER 2 Valve-in-Valve Registry. J Am Coll Cardiol 2017; 69 (18) 2253-2262
MissingFormLabel
- 10 Deeb GM, Chetcuti SJ, Reardon MJ. et al. 1-Year results in patients undergoing transcatheter aortic valve replacement with failed surgical bioprostheses. JACC Cardiovasc Interv 2017; 10 (10) 1034-1044
- 11 Erlebach M, Ruge H, Noebauer C. et al. Transcatheter treatment of balloon-expandable valve structural degeneration: a single-center case series. Thorac Cardiovasc Surg 2019; 67 (S 01): S1-S100