Heater–Cooler Devices and Risk of Contamination during Cardiac Surgery

Mirko Kaluza
1   Department of Cardiothoracic Surgery, Jena University Hospital, Friedrich-Schiller University of Jena, Jena, Germany
2   Life Systems Medizintechnik Service GmbH, Mönchengladbach, Germany
,
Gloria Färber
1   Department of Cardiothoracic Surgery, Jena University Hospital, Friedrich-Schiller University of Jena, Jena, Germany
,
Benjamin May
1   Department of Cardiothoracic Surgery, Jena University Hospital, Friedrich-Schiller University of Jena, Jena, Germany
,
Ute Dobermann
3   Center for Infectious Diseases and Infection Control, Jena University Hospital, Friedrich-Schiller University of Jena, Jena, Germany
,
Mathias W. Pletz
3   Center for Infectious Diseases and Infection Control, Jena University Hospital, Friedrich-Schiller University of Jena, Jena, Germany
,
Birgit Edel
4   Institute of Medical Microbiology, Jena University Hospital, Friedrich-Schiller University of Jena, Jena, Germany
,
Bettina Löffler
4   Institute of Medical Microbiology, Jena University Hospital, Friedrich-Schiller University of Jena, Jena, Germany
,
Torsten Doenst
1   Department of Cardiothoracic Surgery, Jena University Hospital, Friedrich-Schiller University of Jena, Jena, Germany
› Author Affiliations
Funding None.

Abstract

Background Heater–cooler devices (HCD) have been implicated in a cardiosurgical contamination scenario causing prosthetic valve endocarditis.

Aim We characterized contamination of new HCDs and assessed the risk of intraoperative microorganism transmission from the HCD to the operating field.

Methods We initially acquired four new FlexTherm and then four new Maquet HCU40 HCDs and assessed occurrence and speed of microbial contamination (including mycobacteria) assessing swab and water samples from the device. In parallel, we collected repeated samples from different sites in the operating room either by swab sticks or by exposing different sample plates to room air. We also reviewed microbiological results from the hospital and compared them to cardiosurgical wound infections and endocarditis cases. Finally, we simulated cardiosurgical conditions and assessed the devices' ability to expel air to the operative field.

Results All new HCDs were clean before first use. Despite authority-mandated decontamination procedures, microbial growth (Fusarium solani, Sphingomonas paucimobilis, Pseudomonas aeruginosa, Mycobacterium chelonae, and gordonae) was identified in all HCDs over time and could not be permanently eliminated. Four of these mircoorganisms were also found in tap water. However, none of the HCD-organisms were found inside the laminar airflow operating area. Importantly, except for P. aeruginosa, none of the HCD organisms were found in patients with surgical wound infections or endocarditis. HCD-expelled air did not rise more than 40 cm above ground.

Conclusion HCDs cannot be expected to remain sterile despite extensive decontamination procedures. However, airborne transmission of microorganisms directly from the HCD to the operating field appears unlikely.



Publication History

Received: 09 June 2020

Accepted: 09 November 2020

Article published online:
21 April 2021

© 2021. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Beckmann A, Meyer R, Lewandowski J, Markewitz A, Gummert J. German Heart Surgery Report 2019: The Annual Updated Registry of the German Society for Thoracic and Cardiovascular Surgery. Thorac Cardiovasc Surg 2020; 68 (04) 263-276
  • 2 Sax H, Bloemberg G, Hasse B. et al. Prolonged outbreak of Mycobacterium chimaera infection after open-chest heart surgery. Clin Infect Dis 2015; 61 (01) 67-75
  • 3 Asadi T, Mullin K, Roselli E. et al. Disseminated Mycobacterium chimaera infection associated with heater-cooler units after aortic valve surgery without endocarditis. J Thorac Cardiovasc Surg 2018; 155 (06) 2369-2374
  • 4 Diekema DJ. Mycobacterium chimaera infections after cardiovascular surgery: lessons from a global outbreak. Trans Am Clin Climatol Assoc 2019; 130: 136-144
  • 5 Hasse B, Hannan MM, Keller PM. et al; M. chimaera ISCVID Investigators and, ISCVID Executive Committee, Infectious Diseases Specialists, Hospital Epidemiologists, Microbiologists and Molecular Typing Specialists, Cardiac Surgeons/ Perfusionists/ Cardiologists, Ophthalmology, Anaesthesiologists, Public Health. International Society of Cardiovascular Infectious Diseases Guidelines for the diagnosis, treatment and prevention of disseminated Mycobacterium chimaera infection following cardiac surgery with cardiopulmonary bypass. J Hosp Infect 2020; 104 (02) 214-235
  • 6 Sommerstein R, Hasse B, Marschall J. et al; Swiss Chimaera Taskforce. Global health estimate of invasive Mycobacterium chimaera infections associated with heater-cooler devices in cardiac surgery. Emerg Infect Dis 2018; 24 (03) 576-578
  • 7 Walker J, Moore G, Collins S. et al. Microbiological problems and biofilms associated with Mycobacterium chimaera in heater-cooler units used for cardiopulmonary bypass. J Hosp Infect 2017; 96 (03) 209-220
  • 8 Struelens MJ, Plachouras D. Mycobacterium chimaera infections associated with heater-cooler units (HCU): closing another loophole in patient safety. Euro Surveill 2016; 21 (46) 30397
  • 9 BfArM. Möglicher Zusammenhang zwischen Hypothermiegeräten und Infektionsrisiko mit Mykobakterien bei der Herzchirurgie. Online: Accessed November 26, 2020 https://www.bfarm.de/SharedDocs/Risikoinformationen/Medizinprodukte/DE/Hypothermiegeraete.html.
  • 10 FDA. Recommendations for the Use of Any Heater Cooler Device. Online: Accessed November 26, 2020 https://www.fda.gov/medicaldevices/productsandmedicalprocedures/cardiovasculardevices/heater-coolerdevices/ucm492583.htm.
  • 11 DIN e, V. Water quality - General guidance on the enumeration of micro-organisms by culture (ISO 8199:2005), German version EN ISO 8199:2007. Berlin: Beuth-Verlag; 2008
  • 12 DIN e, V. Washer-disinfectors - Part 4: Requirements and tests for washer-disinfectors employing chemical disinfection for thermolabile endoscopes (ISO 15883–4:2008), German version EN ISO 15883–4:2009. Berlin: Beuth-Verlag; 2009
  • 13 van Ingen J, Kohl TA, Kranzer K. et al. Global outbreak of severe Mycobacterium chimaera disease after cardiac surgery: a molecular epidemiological study. Lancet Infect Dis 2017; 17 (10) 1033-1041
  • 14 Baker AW, Lewis SS, Alexander BD. et al. Two-phase hospital-associated outbreak of Mycobacterium abscessus: investigation and mitigation. Clin Infect Dis 2017; 64 (07) 902-911
  • 15 Kaelin MB, Kuster SP, Hasse B. et al. Diversity of nontuberculous mycobacteria in Heater-Cooler Devices - results from prospective surveillance. J Hosp Infect 2020; ••• :S0195-6701(20)30105-5; [epub ahead of print] DOI: 10.1016/j.jhin.2020.03.006.
  • 16 Götting T, Klassen S, Jonas D. et al. Heater-cooler units: contamination of crucial devices in cardiothoracic surgery. J Hosp Infect 2016; 93 (03) 223-228
  • 17 Sommerstein R, Rüegg C, Kohler P, Bloemberg G, Kuster SP, Sax H. Transmission of Mycobacterium chimaera from heater-cooler units during cardiac surgery despite an ultraclean air ventilation system. Emerg Infect Dis 2016; 22 (06) 1008-1013
  • 18 Falkinham III JO. Disinfection and cleaning of heater-cooler units: suspension- and biofilm-killing. J Hosp Infect 2020; ••• :S0195-6701 (20)30236-X; [epub ahead of print] DOI: 10.1016/j.jhin.2020.05.005.
  • 19 Sorin Group. Herzchirurgie: Herzchirurgie: Risiko durch Desinfektion und Reinigung von Hypothermiegeräten von Sorin. Online: Accessed November 26, 2020 https://www.bfarm.de/SharedDocs/Kundeninfos/DE/12/2015/01223-15_kundeninfo_de.pdf?__blob=publicationFile&v=6.
  • 20 Antonation K, Patel S, Waddell JT. et al; Canadian Public Health Laboratory Network. Interim laboratory testing guidance for the detection of non-tuberculous Mycobacterium (NTM) infections in post-operative patients exposed to heater-cooler units. Can Commun Dis Rep 2017; 43 (01) 25-28
  • 21 DIN e, V. Ventilation and air conditioning - Part 4: Ventilation in buildings and rooms of health care (DIN 1946–4:2008–12). Berlin: Beuth-Verlag; 2008
  • 22 Schwandtner S, Reichel H, Jatzwauk L, Matschke KE. Investigation and evaluation of potential aerosol release by Maquet/Getinge heater-cooler units used during cardiac surgery. Thorac Cardiovasc Surg 2019; 67 (03) 203-211