J Knee Surg 2021; 34(14): 1560-1569
DOI: 10.1055/s-0040-1710379
Original Article

Feasibility and 3D Planning of a Novel Patient-Specific Instrumentation Technique in Medial Opening-Wedge High Tibial Osteotomy

Wouter Van Genechten
1   Faculty of Medicine, Antwerp University, Antwerp, Belgium
2   More Foundation, AZ Monica, Antwerp, Belgium
,
Wouter Van Tilborg
1   Faculty of Medicine, Antwerp University, Antwerp, Belgium
,
Maxim Van den Bempt
1   Faculty of Medicine, Antwerp University, Antwerp, Belgium
,
Annemieke Van Haver
2   More Foundation, AZ Monica, Antwerp, Belgium
,
Peter Verdonk
1   Faculty of Medicine, Antwerp University, Antwerp, Belgium
2   More Foundation, AZ Monica, Antwerp, Belgium
3   ORTHOCA, Antwerp, Belgium
› Author Affiliations
Funding None.

Abstract

A novel approach for opening-wedge high tibial osteotomy (OWHTO) with patient-specific instrumentation (PSI) was evaluated for its safety, feasibility, and accuracy. Next, the mechanical medial proximal tibial angle (mMPTA) was assessed as a potential planning angle by investigating the relation with the mechanical femorotibial angle (mFTA). Ten OWHTO cases were 3D planned using the mMPTA and operated with a customized 3D-printed wedge and cast which resembled the intended osteotomy opening. Patients were closely monitored for intraoperative and postoperative complications up to 1 year after surgery. Radiological assessment was conducted on full leg standing radiographs and supine lower limb computed tomography-scans preoperatively and 3 months after surgery. No intraoperative complications or logistical issues during PSI processing were observed. Absolute accuracy outcomes showed a correction error of 1.3° ± 1.1 mMPTA and 0.9° ± 0.6 mFTA with all osteotomies falling in (−2°; + 2°) mFTA around the target. The mMPTA and mFTA were found to have a strong correlation in both 3D (r = 0.842, p = 0.002) and 2D (r = 0.766, p = 0.01) imaging for effective correction. The study confirmed the development of a safe and feasible PSI technique in OWHTO with excellent accuracy outcomes. The strong correlation between the mMPTA and mFTA indicated that soft tissue changes after OWHTO are of minor significance to the final alignment in ligament-stable patients. Finally, the mMPTA was found to be a reliable planning angle in 3D software for obtaining the intended lower limb realignment and its use can therefore be recommended in modern OWHTO planning.



Publication History

Received: 11 December 2019

Accepted: 28 March 2020

Article published online:
22 May 2020

© 2020. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Van den Bempt M, Van Genechten W, Claes T, Claes S. How accurately does high tibial osteotomy correct the mechanical axis of an arthritic varus knee? A systematic review. Knee 2016; 23 (06) 925-935
  • 2 Martay JL, Palmer AJ, Bangerter NK. et al. A preliminary modeling investigation into the safe correction zone for high tibial osteotomy. Knee 2018; 25 (02) 286-295
  • 3 Niinimäki TT, Eskelinen A, Ohtonen P, Junnila M, Leppilahti J. Incidence of osteotomies around the knee for the treatment of knee osteoarthritis: a 22-year population-based study. Int Orthop 2012; 36 (07) 1399-1402
  • 4 Nwachukwu BU, McCormick FM, Schairer WW, Frank RM, Provencher MT, Roche MW. Unicompartmental knee arthroplasty versus high tibial osteotomy: United States practice patterns for the surgical treatment of unicompartmental arthritis. J Arthroplasty 2014; 29 (08) 1586-1589
  • 5 National Joint Registry for England, Wales and Northern Ireland. 13th Annual Report. Published 2016. Accessed August 27, 2019 at: http://www.njrcentre.org.uk/njrcentre/Portals/0/Documents/England/Reports/13thAnnualReport/07950NJRAnnualReport2016ONLINEREPORT.pdf
  • 6 Darees M, Putman S, Brosset T, Roumazeille T, Pasquier G, Migaud H. Opening-wedge high tibial osteotomy performed with locking plate fixation (TomoFix) and early weight-bearing but without filling the defect. A concise follow-up note of 48 cases at 10 years' follow-up. Orthop Traumatol Surg Res 2018; 104 (04) 477-480
  • 7 Hantes ME, Natsaridis P, Koutalos AA, Ono Y, Doxariotis N, Malizos KN. Satisfactory functional and radiological outcomes can be expected in young patients under 45 years old after open wedge high tibial osteotomy in a long-term follow-up. Knee Surg Sports Traumatol Arthrosc 2018; 26 (11) 3199-3205
  • 8 Rodriguez-Merchan EC. Does a previous high tibial osteotomy (HTO) influence the long-term function or survival of a total knee arthroplasty (TKA)?. Arch Bone Jt Surg 2018; 6 (01) 19-22
  • 9 Pérez-Mañanes R, Burró JA, Manaute JR, Rodriguez FC, Martín JV. 3D surgical printing cutting guides for open-wedge high tibial osteotomy: do it yourself. J Knee Surg 2016; 29 (08) 690-695
  • 10 Hankemeier S, Mommsen P, Krettek C. et al. Accuracy of high tibial osteotomy: comparison between open- and closed-wedge technique. Knee Surg Sports Traumatol Arthrosc 2010; 18 (10) 1328-1333
  • 11 Wu Z-P, Zhang P, Bai J-Z. et al. Comparison of navigated and conventional high tibial osteotomy for the treatment of osteoarthritic knees with varus deformity: a meta-analysis. Int J Surg 2018; 55: 211-219
  • 12 Elson DW. The surgical accuracy of knee osteotomy. Knee 2017; 24 (02) 167-169
  • 13 Victor J, Premanathan A. Virtual 3D planning and patient specific surgical guides for osteotomies around the knee: a feasibility and proof-of-concept study. Bone Joint J 2013; 95-B (Suppl 11A(: 153-158
  • 14 Lee DH, Nha KW, Park SJ, Han SB. Preoperative and postoperative comparisons of navigation and radiologic limb alignment measurements after high tibial osteotomy. Arthroscopy 2012; 28 (12) 1842-1850
  • 15 Saragaglia D, Roberts J. Navigated osteotomies around the knee in 170 patients with osteoarthritis secondary to genu varum. Orthopedics 2005; 28 (Suppl. 10) s1269-s1274
  • 16 Iorio R, Pagnottelli M, Vadalà A. et al. Open-wedge high tibial osteotomy: comparison between manual and computer-assisted techniques. Knee Surg Sports Traumatol Arthrosc 2013; 21 (01) 113-119
  • 17 Sarment DP, Al-Shammari K, Kazor CE. Stereolithographic surgical templates for placement of dental implants in complex cases. Int J Periodontics Restorative Dent 2003; 23 (03) 287-295
  • 18 Lu S, Zhang YZ, Wang Z. et al. Accuracy and efficacy of thoracic pedicle screws in scoliosis with patient-specific drill template. Med Biol Eng Comput 2012; 50 (07) 751-758
  • 19 Byrne A-M, Impelmans B, Bertrand V, Van Haver A, Verstreken F. Corrective osteotomy for malunited diaphyseal forearm fractures using preoperative 3-dimensional planning and patient-specific surgical guides and implants. J Hand Surg Am 2017; 42 (10) 836.e1-836.e12
  • 20 Munier M, Donnez M, Ollivier M. et al. Can three-dimensional patient-specific cutting guides be used to achieve optimal correction for high tibial osteotomy? Pilot study. Orthop Traumatol Surg Res 2017; 103 (02) 245-250
  • 21 Donnez M, Ollivier M, Munier M. et al. Are three-dimensional patient-specific cutting guides for open wedge high tibial osteotomy accurate? An in vitro study. J Orthop Surg Res 2018; 13 (01) 171
  • 22 Sheehy L, Cooke TDV. Radiographic assessment of leg alignment and grading of knee osteoarthritis: a critical review. World J Rheumatol 2015; 5 (02) 69-82
  • 23 Kellgren JH, Lawrence JS. Radiological assessment of osteo-arthrosis. Ann Rheum Dis 1957; 16 (04) 494-502
  • 24 Takeuchi R, Ishikawa H, Kumagai K. et al. Fractures around the lateral cortical hinge after a medial opening-wedge high tibial osteotomy: a new classification of lateral hinge fracture. Arthroscopy 2012; 28 (01) 85-94
  • 25 Kim H-J, Park J, Shin J-Y, Park I-H, Park K-H, Kyung H-S. More accurate correction can be obtained using a three-dimensional printed model in open-wedge high tibial osteotomy. Knee Surg Sport Traumatol Arthrosc 2018; 26 (11) 3452-3458
  • 26 Yang JCS, Chen CF, Luo CA. et al. Clinical experience using a 3D-printed patient-specific instrument for medial opening wedge high tibial osteotomy. BioMed Res Int 2018; 2018: 9246529
  • 27 Brouwer RW, Bierma-Zeinstra SM, van Koeveringe AJ, Verhaar JA. Patellar height and the inclination of the tibial plateau after high tibial osteotomy. The open versus the closed-wedge technique. J Bone Jt Surg 2005; 87 (09) 1227-1232
  • 28 Kawakami H, Sugano N, Yonenobu K. et al. Effects of rotation on measurement of lower limb alignment for knee osteotomy. J Orthop Res 2004; 22 (06) 1248-1253
  • 29 Ogawa H, Matsumoto K, Ogawa T, Takeuchi K, Akiyama H. Preoperative varus laxity correlates with overcorrection in medial opening wedge high tibial osteotomy. Arch Orthop Trauma Surg 2016; 136 (10) 1337-1342
  • 30 Henckel J, Richards R, Lozhkin K. et al. Very low-dose computed tomography for planning and outcome measurement in knee replacement. The imperial knee protocol. J Bone Joint Surg Br 2006; 88 (11) 1513-1518
  • 31 DePuy Orthopaedics Inc. Radiation Exposure Considerations with the Use of TruMatch Personalized Solutions. 2010. Accessed September 12, 2019
  • 32 Miniaci A, Ballmer FT, Ballmer PM, Jakob RP. Proximal tibial osteotomy. A new fixation device. Clin Orthop Relat Res 1989; (246) 250-259
  • 33 Dugdale TW, Noyes FR, Styer D. Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length. Clin Orthop Relat Res 1992; (274) 248-264
  • 34 Kubota M, Ohno R, Sato T, Yamaguchi J, Kaneko H, Kaneko K. The medial proximal tibial angle accurately corrects the limb alignment in open-wedge high tibial osteotomy. Knee Surg, Sport Traumatol Arthrosc 2019; 27 (08) 2410-2416
  • 35 Fujisawa Y, Masuhara K, Shiomi S. The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am. 1979;10(3):585–608
  • 36 van de Pol GJ, Verdonschot N, van Kampen A. The value of the intra-operative clinical mechanical axis measurement in open-wedge valgus high tibial osteotomies. Knee 2012; 19 (06) 933-938
  • 37 Martay JL, Palmer AJ, Bangerter NK. et al. A preliminary modeling investigation into the safe correction zone for high tibial osteotomy. Knee 2018; 25 (02) 286-295
  • 38 Stanley JC, Robinson KG, Devitt BM. et al. Computer assisted alignment of opening wedge high tibial osteotomy provides limited improvement of radiographic outcomes compared to flouroscopic alignment. Knee 2016; 23 (02) 289-294
  • 39 Hohloch L, Kim S, Mehl J. et al. Customized post-operative alignment improves clinical outcome following medial open-wedge osteotomy. Knee Surg Sports Traumatol Arthrosc 2018; 26 (09) 2766-2773
  • 40 Marti CB, Gautier E, Wachtl SW, Jakob RP. Accuracy of frontal and sagittal plane correction in open-wedge high tibial osteotomy. Arthroscopy 2004; 20 (04) 366-372
  • 41 Feucht MJ, Minzlaff P, Saier T. et al. Degree of axis correction in valgus high tibial osteotomy: proposal of an individualised approach. Int Orthop 2014; 38 (11) 2273-2280
  • 42 Victor J, Van Doninck D, Labey L, Innocenti B, Parizel PM, Bellemans J. How precise can bony landmarks be determined on a CT scan of the knee?. Knee 2009; 16 (05) 358-365
  • 43 Auricchio F, Marconi S. 3D printing: clinical applications in orthopaedics and traumatology. EFORT Open Rev 2017; 1 (05) 121-127
  • 44 Starosolski ZA, Kan JH, Rosenfeld SD, Krishnamurthy R, Annapragada A. Application of 3-D printing (rapid prototyping) for creating physical models of pediatric orthopedic disorders. Pediatr Radiol 2014; 44 (02) 216-221
  • 45 Van den Bempt M, Liebregts J, Maal T, Bergé S, Xi T. Toward a higher accuracy in orthognathic surgery by using intraoperative computer navigation, 3D surgical guides, and/or customized osteosynthesis plates: a systematic review. J Craniomaxillofac Surg 2018; 46 (12) 2108-2119