CC BY 4.0 · Aorta (Stamford) 2020; 08(01): 001-005
DOI: 10.1055/s-0039-1700999
Original Research Article
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Management of Aortic Pseudoaneurysms: Evolving Concepts and Controversies

1   Department of Cardiothoracic Surgery, John Fitzgerald Kennedy Medical Center, Atlantis, Florida
,
Brian D. Conway
2   Department of Cardiothoracic Surgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa
,
Marcos A. Nores
1   Department of Cardiothoracic Surgery, John Fitzgerald Kennedy Medical Center, Atlantis, Florida
› Author Affiliations
Funding None.
Further Information

Address for correspondence

Sotiris C. Stamou, MD
Department of Cardiothoracic Surgery, John Fitzgerald Kennedy Medical Center
180 John Fitzgerald Kennedy Drive, Suite 320, Atlantis, FL 33462

Publication History

15 December 2018

02 November 2019

Publication Date:
29 June 2020 (online)

 

Abstract

Background Techniques to repair aortic pseudoaneurysms have been rapidly evolving. We present our results following open and endovascular repair of aortic pseudoaneurysms from 2009 to 2013.

Methods A total of nine patients underwent pseudoaneurysm repair from April 2009 to February 2013. Of them, five underwent open repair and four underwent endovascular repair. The median age was 58 years (range, 40–72 years) and two (22%) were females. Preoperative, operative, and postoperative data are presented along with operative modality.

Results Two patients died during the period of study. Patient 1 died from massive hemorrhage at the site of prior stenting. Patient 7 died from postoperative cardiac arrest and respiratory failure. A single patient required hemorrhage-related reexploration. None of the patients experienced stroke or acute renal failure following repair. Median hospital and intensive care unit length of stays were 7.1 (range, 1–20) and 2.0 (range, 1–5), respectively.

Conclusions Pseudoaneurysm repair can be effectively achieved through open or percutaneous repair but only after careful consideration of anatomical constraints, as well as patient comorbidities.


#

Introduction

False aneurysms of the aorta, known as pseudoaneurysms, are hematomas formed outside the aortic wall, resulting from transmural disruption with the leak contained by surrounding mediastinal tissues. Previous cardiac surgery is the most frequent cause.[1] Typically pseudoaneurysms are a rare complication of aortic repair; however, in some studies, the incidence of pseudoaneurysm formation has been documented to manifest in as many as 7.7% of patients following aortic procedures.[2] Mechanisms implicated include infection, trauma, poor anastomotic technique, and intrinsic aortic wall disease.[1]

Surgical treatments vary according to the features and locations of the pseudoaneurysm. Surgical challenges are frequent, especially in the presence of infection, prior cardiac surgery, and proximity of the pseudoaneurysm with the posterior sternal table making reentry particularly challenging. Less invasive options with coil embolization and pseudoaneurysm exclusion have also been reported.[3] [4] [5] Few studies have addressed the treatment of this complication. Herein, we describe our experience with endovascular and open surgical repair techniques for patients with pseudoaneurysms of the thoracic aorta.


#

Materials and Methods

From April 2009 to February 2013, a total of nine patients underwent repair of pseudoaneurysms of the ascending and thoracic aorta ([Table 1]). Preoperative, operative, and postoperative data were obtained by review of medical records. Mode of death was identified through review of clinical records and death certificates. Prior to this analysis, study approval from the Institutional Review Boards of each center was obtained. Consistent with the Health Insurance Portability and Accountability Act of 1996 (HIPAA), patient confidentiality was consistently maintained. Long-term survival data were obtained from the Social Security Death Index ( http://search.ancestry.com/search/db.aspx?dbid=3693 ). Follow-up was 100% completed. Since social security death index has a 2-year blank out interval, we used obituary search where appropriate.

Table 1

Patient characteristics

Patient no.

Age (y)

Gender

Previous operation

Indication for repair

Operative interval (mo)

Repair date

Procedure

Outcome

1

65

Male

Bentall, March 2012

Bleed from distal suture line

2

May 2012

Redo the Bentall procedure with 29-mm valved conduit

Deceased in 2012 (bleeding from the native aorta at the previous stent site; cardiac arrest)

2

54

Male

Prosthetic aortic valve, January 2009

Endocarditis with pseudoaneurysm at aortotomy suture line

5

June 2009

Redo the Bentall procedure with 28-mm valved conduit

Alive

3

40

Male

Bentall, March 2007

Endocarditis with pseudoaneurysm at the distal suture line

63

June 2012

Redo the Bentall procedure with 25-mm valved conduit

Alive

4

60

Female

Ascending aorta replacement with aortic valve resuspension and CABG, April 2009; descending aorta replacement, September 2009; AVR, June 2011

Patient with Loeys–Dietz syndrome and pseudoaneurysm of both the proximal and distal suture lines

49

May 2013

Redo the Bentall procedure with bioprosthetic valve

Alive

5

68

Male

Ascending aorta replacement, June 2008

Pseudoaneurysm from distal suture line

32

April 2012

Resection of pseudoaneurysm under circulatory arrest

Alive

6

59

Male

CABG, November 2011

Ascending aortic pseudoaneurysm 2 cm above the RCA origin

20

December 2012

Six coil embolization wires, 10-mm Amplatzer atrial septal occluder device deployed under fluoroscopic guidance within the neck of the pseudoaneurysm

Alive

7

72

Male

Aorta to innominate and left subclavian bypass, 1992; pseudomonas graft infection requiring graft take-down, December 2007

Pseudoaneurysm from prior aortotomy site

55

June 2012

36 × 77 TX2 Cook thoracic endograft into the ascending aorta extending to the level of the left common carotid

Deceased (cardiac arrest; respiratory failure)

8

38

Female

Coarctation repair, 1978; MVA, 2007

Pseudoaneurysm at the previous repair site

412

April 2012

28 × 28 ×15 Tag (Gore) deployed in the descending aorta

Alive

9

68

Male

Coarctation repair, 1965

Pseudoaneurysm at the previous repair site

578

February 2013

28 × 10 Excluder (Gore) deployed in the descending aorta

Alive

Abbreviations: AVR, aortic valve replacement; CABG, coronary artery bypass grafting; MVA, motor vehicle accident; RCA, right coronary artery.


Surgical Technique

Routine intraoperative transesophageal echocardiography was performed. Surgical technique varied based on the location of the pseudoaneurysm, history of previous cardiac surgery, proximity of the pseudoaneurysm with the posterior sternal table, presence of infection, and need for associated cardiac procedures. Median sternotomy was performed in five patients who underwent surgical repair of aortic root, ascending aorta, or aortic arch pseudoaneurysms. Arterial cannulation site was the femoral artery in three patients, axillary artery in one patient, and distal ascending aorta in one patient. Institution of cardiopulmonary bypass prior to sternal reentry was necessary in three patients to prevent accidental entry into the aneurysm because of proximity with the sternum. Cardiopulmonary bypass was instituted abruptly following pseudoaneurysm entry for one patient. Deep hypothermia and circulatory arrest was used in five patients, with antegrade cerebral perfusion in three patients. A small left anterior thoracotomy was performed in one patient to vent the left ventricle and prevent ventricular distention.


#

Endovascular Repair

Endovascular repair was performed in four patients. Two patients had pseudoaneurysms of the descending thoracic aorta after repair of coarctation of the aorta and underwent repair with endovascular graft excluder of the pseudoaneurysms. One patient underwent aortic arch debranching and transaortic deployment of an endograft to exclude an arch pseudoaneurysm at a simultaneous setting. One patient with history of previous coronary bypass surgery developed a pseudoaneurysm at the aortic root vent site and underwent successful coil embolization and pseudoaneurysm exclusion.


#
#

Results

Preoperative Characteristics

A total of 22% of patients were females, median age was 58 years (range, 40–72 years). Clinical presentation varied according to the location of pseudoaneurysm. Most common manifestations included chest pain (n = 1), sepsis (n = 3), and heart failure (n = 2). Descending aortic pseudoaneurysms were asymptomatic and were identified as incidental findings on computed tomography. The location of the pseudoaneurysm was involving the proximal suture line in one patient and the distal suture line in four patients with aortic root or ascending aortic pseudoaneurysms. Infection was present in four patients and two patients had a history of endocarditis. Positive blood cultures were present in two patients.


#

Operative Characteristics

[Table 1] demonstrates the operative findings of patients as well as the interval period between the initial operation and development of the pseudoaneurysm. Patients 1 to 5 were all approached through the traditional open surgical method, while patients 6 to 9 underwent device deployment under fluoroscopic guidance. Most of the patients (7 of 9) had a pseudoaneurysm of the ascending aorta and only two patients had pseudoaneurysms of the descending aorta after previous coarctation repair.


#

Postoperative Characteristics

Two patients died during the period of the study. Patient 1 died from massive hemorrhage at the site of prior stenting. Patient 7 died from postoperative cardiac arrest and respiratory failure. A single patient required hemorrhage-related reexploration. No patients experienced stroke or acute renal failure following repair. Median hospital and intensive care unit length of stay were 7.1 (range, 1–20) and 2.0 (range, 1–5), respectively.


#
#

Discussion

Indications for Repair

Most patients present with symptoms of chest pain, heart failure or symptoms related to sepsis. In our series, the main indications to intervene were symptoms and risk of impending rupture.[1] Size of the pseudoaneurysm was not used as a criterion for surgical intervention in our study. Although an incidental finding of pseudoaneurysm of descending aorta as a result of previous coarctation repair may occur, most patients were symptomatic. Common causes of pseudoaneurysms include leak at the anastomotic or cannulation sites, especially in patients with previous dissection repairs. Most patients are young but have had previous cardiovascular surgery; many have endocarditis. Most of our patients required ascending aorta and/or aortic root replacement.


#

Technical Challenges of Repair

Repair of pseudoaneurysms of the aorta is often complicated and associated with significant morbidity and mortality, especially when the pseudoaneurysm is in close proximity to the underside of the sternum. Open repair of these lesions may still be approached through a median sternotomy; however, some hypothesize that those more closely related to the sternum may be better candidates for a right anterior thoracotomy or a minimally invasive “J” incision.[1] However, measures were often taken to ensure safety. Cardiopulmonary bypass, for example, may be initiated before sternal entry in patients with a pseudoaneurysm lying in close approximation to the sternum. The pseudoaneurysm for patient 3 in our cohort was punctured upon initial entry into the chest requiring immediate initiation of cardiopulmonary bypass. The remaining three patients that had pseudoaneurysms abutting the sternum all underwent cardiopulmonary bypass via the femoral vessels prior to sternal reentry.


#

Percutaneous Repair: Pitfalls and Limitations

In the high risk setting, a minimally invasive approach using endovascular grafts or atrial septal occlusion devices can ameliorate some risks associated with open procedures, while providing adequate exclusion of the pseudoaneurysm sac. However, percutaneous devices are not without limitation. One requirement for occlusion device placement is a narrow neck between the pseudoaneurysm and the aorta to maintain adequate device seal upon deployment. Also, coil embolization can be useful to help achieving stasis within the pseudoaneurysm sac prior to device deployment; however, too many coils can push the device out of the sac, as was the case for patient 5. The situation necessitated an open approach with pseudoaneurysm resection less than 1 year following the prior repair ([Fig. 1]). In contrast, patient 6 underwent coil embolization of the pseudoaneurysm sac ([Fig. 1]) prior to occluder placement and has since been asymptomatic.

Zoom Image
Fig. 1 (A) Extruded occluder device into the peudoaneurysm sac requiring reintervention. (B) The occluder and aneurysm sac were removed surgically and the incision was reapproximated with felt strips. (C): Pseudoaneurysm successfully excluded after Amplatz's excluder deployment. (D) Repair of ascending aortic pseudoaneurysm with coil embolization prior to percutaneous occlusion device placement.

Endovascular grafts have also been used for high-risk patients with device deployment over the orifice of the lesion.[5] Patients 7 to 9 underwent successful endovascular repair of pseudoaneurysms that would have either required a significantly more complicated open surgical route than the traditional approach or were better candidates for the endovascular approach due to the location of the lesion. For example, patients 8 and 9 both exhibited lesions in the descending aorta where adequate covering of the pseudoaneurysm was fairly easier to achieve without impinging upon other vessels. The pseudoaneurysm in patient 7 resided in close approximation to the manubrium. In this case, endograft deployment allowed for exclusion of the pseudoaneurysm without a median sternotomy. Often however, complete coverage of the lesion along with adequate proximal and distal sealing zones may be difficult to achieve when the pseudoaneurysm arises near the origin of the head vessels. Endovascular approach is often more feasible in patients with pseudoaneurysms of the descending aorta, as compared with those of the ascending aorta given the presence of adequate proximal and distal landing zone.


#
#

Conclusions

Our review demonstrates the challenges of repairing pseudoaneurysms and the variety of treatment modalities effective in repairing these lesions. We conclude that pseudoaneurysm repair can be effectively achieved through open or percutaneous repair but only after careful consideration of anatomical constraints, as well as patient comorbidities.


#
#

Conflict of Interest

The authors declare no conflict of interest related to this article.

Acknowledgment

None.

  • References

  • 1 Atik FA, Navia JL, Svensson LG. , et al. Surgical treatment of pseudoaneurysm of the thoracic aorta. J Thorac Cardiovasc Surg 2006; 132 (02) 379-385
  • 2 Katzenschlager R, Ugurluoglu A, Ahmadi A. , et al. Incidence of pseudoaneurysm after diagnostic and therapeutic angiography. Radiology 1995; 195 (02) 463-466
  • 3 Kpodonu J, Wheatley III GH, Ramaiah VG, Rodriguez-Lopez JA, Strumpf RK, Diethrich EB. Endovascular repair of an ascending aortic pseudoaneurysm with a septal occluder device: mid-term follow-up. Ann Thorac Surg 2008; 85 (01) 349-351
  • 4 Chapot R, Aymard A, Saint-Maurice JP, Bel A, Merland JJ, Houdart E. Coil embolization of an aortic arch false aneurysm. J Endovasc Ther 2002; 9 (06) 922-925
  • 5 Schwill S, LeMaire SA, Green SY, Bakaeen FG, Coselli JS. Endovascular repair of thoracic aortic pseudoaneurysms and patch aneurysms. J Vasc Surg 2010; 52 (04) 1034-1037

Address for correspondence

Sotiris C. Stamou, MD
Department of Cardiothoracic Surgery, John Fitzgerald Kennedy Medical Center
180 John Fitzgerald Kennedy Drive, Suite 320, Atlantis, FL 33462

  • References

  • 1 Atik FA, Navia JL, Svensson LG. , et al. Surgical treatment of pseudoaneurysm of the thoracic aorta. J Thorac Cardiovasc Surg 2006; 132 (02) 379-385
  • 2 Katzenschlager R, Ugurluoglu A, Ahmadi A. , et al. Incidence of pseudoaneurysm after diagnostic and therapeutic angiography. Radiology 1995; 195 (02) 463-466
  • 3 Kpodonu J, Wheatley III GH, Ramaiah VG, Rodriguez-Lopez JA, Strumpf RK, Diethrich EB. Endovascular repair of an ascending aortic pseudoaneurysm with a septal occluder device: mid-term follow-up. Ann Thorac Surg 2008; 85 (01) 349-351
  • 4 Chapot R, Aymard A, Saint-Maurice JP, Bel A, Merland JJ, Houdart E. Coil embolization of an aortic arch false aneurysm. J Endovasc Ther 2002; 9 (06) 922-925
  • 5 Schwill S, LeMaire SA, Green SY, Bakaeen FG, Coselli JS. Endovascular repair of thoracic aortic pseudoaneurysms and patch aneurysms. J Vasc Surg 2010; 52 (04) 1034-1037

Zoom Image
Fig. 1 (A) Extruded occluder device into the peudoaneurysm sac requiring reintervention. (B) The occluder and aneurysm sac were removed surgically and the incision was reapproximated with felt strips. (C): Pseudoaneurysm successfully excluded after Amplatz's excluder deployment. (D) Repair of ascending aortic pseudoaneurysm with coil embolization prior to percutaneous occlusion device placement.