RSS-Feed abonnieren

DOI: 10.1055/s-0039-1693044
Comparative Evaluation of Cross-table and Ducroquet Incidences for Measurement of the Hip Alpha Angle[∗]
Artikel in mehreren Sprachen: português | EnglishEndereço para correspondência
Publikationsverlauf
05. März 2019
22. Januar 2019
Publikationsdatum:
20. August 2019 (online)
Abstract
Objective The purpose of the present paper is to compare the equivalence of the measurement of the alpha angle using the Ducroquet and cross-table lateral views.
Methods We have recruited 90 patients, resulting in 95 hips. We have standardized the realization of the radiographic views. The incidence of the lateral cross-table views were taken with 15° of internal rotation with the patient in the supine position, and the incidence of the Ducroquet views was standardized with the patient in the supine position, with 90° of flexion and 45° of abduction of the hip. The alpha angle was measured in both lateral views, by two musculoskeletal radiologists. The measurements were performed in 2 different times: an initial evaluation and another 4 weeks afterwards. The t Student test was used and calculated the intraclass correlation coefficient (ICC).
Results We have found a good intraobserver correlation for both views in different times; there was no statistically significant difference between the measurements performed by the two views. However, the interobserver correlation was low.
Conclusion In conclusion, the Ducroquet profile view is a good choice for the α angle measurement and can be used instead of the cross-table view.
#
Introduction
Femoroacetabular impingement (FAI) is a well-established entity in world orthopedics.[1] [2] [3] [4] [5] [6] It is considered one of the main mechanically originated processes resulting in hip arthrosis.[1] [3] [4] [6] [7] [8] [9] Its diagnosis is aided by well-defined radiographic parameters.[2] [4] [10] Most of the morphological alterations of this condition are not visible in anteroposterior hip radiographies.[2] [3] [4] Profile views demonstrate better the nonspherical portion of the femoral neck and the deformities caused by FAI.[8] [9] [11] [12] [13]
This nonspherical portion of the femoral head-neck joint can be measured with the alpha angle (Nötzli angle).[8] [12] The alpha angle is formed by a line drawn through the center of the femoral head, following the femoral neck axis, and another line connecting the center of the femoral head to the point where the femoral head protrudes beyond a circle drawn around the femoral head (the point where the femoral head sphericity ends).[8] [12] In its original description, the angle was measured on oblique axial magnetic resonance imaging (MRI).
Several profile views were described to investigate femoral neck abnormalities, but the most commonly used is the cross-table view.[5] [6] [14] The Ducroquet profile view is another option, easy to perform regardless of the table and requiring only 90° flexion and 30° to 45° abduction.[12] Since it is technically easy, including intraoperatively during hip arthroscopy, it is our imaging of choice to evaluate the alpha angle.
The present study aims to compare the equivalence of the measurement of the alpha angle using the Ducroquet and cross-table views.
#
Materials and Methods
This is a prospective study performed at the Department of Orthopedics and Traumatology of at Santa Casa de Misericórdia de São Paulo Medical School from January 2008 to April 2010. A total of 90 patients were recruited, resulting in 95 hips, which were voluntarily selected and radiographed in the Ducroquet and cross-table views. Informed consent was obtained from all of the patients, and the study was approved by the Institutional Review Board under the number 240/09.
Radiographies
The radiographic views were standardized. All of the views were performed by the same technicians, using the same technique, and were supervised by an orthopedist. The cross-table view ([Figs. 1A] and [1B]) was obtained with the patient in the supine position, with the studied lower limb in 15° internal rotation and the contralateral limb in 90° flexion to avoid image interposition, as recommended by the technique, whereas the Ducroquet view ([Figs. 1C] and [1D]) was standardized with the patient in dorsal recumbency, 90° flexion, and 45° abduction of the affected hip, in neutral rotation.


#
Radiographic Measurement
The alpha angle (Nötzli angle)[8] [12] was determined on both profile views by two musculoskeletal radiologists using the same measurement techniques.[8] [13] The angle was measured digitally with the Image software, version 1.37 (National Institutes of Health, Bethesda, MD, USA).
The measurements were performed at two different time points: at the initial evaluation (referred as “pre”) and 4 weeks afterwards (referred as “post”). The statistical analysis was performed with a summary of variables, boxplot graphs, and scatter diagrams. The Student t-test was used, and the intraclass correlation coefficient (ICC) was calculated with PASW Statistics for Windows, Version 10.0 (SPSS Inc., Chicago, IL, USA). The level of significance was determined at 0.05 (5%).
#
#
Results
The measurements of the alpha angle were similar for both observers at the two time points, that is, at baseline and after 4 weeks ([Fig. 2] and [Table 1]).


Observer |
Radiographic View |
Time |
Mean (°) ± SD |
Median (°) |
---|---|---|---|---|
1 |
Cross-Table |
pre |
49.8 ± 7.43 |
50.1 |
post |
49 ± 7.31 |
48.5 |
||
1 |
Ducroquet |
pre |
50.2 ± 8.32 |
49.8 |
post |
48 ± 7.89 |
48.2 |
||
2 |
Cross-Table |
pre |
44.9 ± 9.77 |
42.3 |
post |
45.4 ± 8.68 |
45.5 |
||
2 |
Ducroquet |
pre |
45.2 ± 9.22 |
45.2 |
post |
44.9 ± 7.88 |
44.4 |
The following analysis was performed:
-
A) To compare the results from observers 1 and 2 for each radiographic view in the 1st and 2nd evaluation (pre and post).
Regarding the analysis among observers:
-
A.1) Cross-table: there was a disparity between the observers 1 and 2 at the pre-evaluation ([Table 2] and [Fig. 3A]) and at the postevaluation ([Table 2] and [Fig. 3B]).
-
A.2) Ducroquet: there was disparity between observers 1 and 2 at the pre-evaluation ([Table 2] and [Fig. 3C]) and at the postevaluation ([Table 2] and [Fig. 3D]).
There was a statistically significant difference (p = 0.000) between measurements between observers for both incidences at both time points.
-
-
B) To compare the correlation of the measurements of the cross-table and Ducroquet views for each observer at both time points.
-
B.1) There was little disparity between observers 1 and 2 in the measurements of the hip angles in both views at the same time ([Table 2] and [Fig. 4A]): observer 1, 1st measurement; [Table 2] and [Fig. 4B]: observer 1, 2nd measurement; [Table 2] and [Fig. 4C]: observer 2, 1st measurement; [Table 2] and [Fig. 4D]: observer 2, 2nd measurement.
-
Analysis |
Intraclass Correlation Coefficients |
95%CI |
---|---|---|
CT Obs1 (pre) x CT Obs2 (pre) |
0.588 |
0.381–0.726 |
CT Obs1 (post) x CT Obs2 (post) |
0.653 |
0.397–0.790 |
DC Obs1 (pre) x DC Obs2 (pre) |
0.578 |
0.226–0.754 |
DC Obs1 (post) x DC Obs2 (post) |
0.718 |
0.405–0.847 |
CT Obs1 (pre) x DC Obs1 (pre) |
0.938 |
0.907–0.959 |
CT Obs1 (post) x DC Obs1 (post) |
0.969 |
0.954–0.979 |
CT Obs2 (pre) x DC Obs2 (pre) |
0.862 |
0.793–0.908 |
CT Obs2 (post) x DC Obs2 (post) |
0.945 |
0.918–0.964 |




There was no statistically significant difference (p > 0.05) in the alpha angle measured on both radiographic views by the same observer at the same time ([Table 3]).
Analysis |
p-value |
|
---|---|---|
1 |
Cross-table (Obs1 pre) – Ducrocquet (Obs1 pre) |
0.309 |
2 |
Cross-table (Obs2 pre) – Ducrocquet (Obs2 pre) |
0.611 |
3 |
Cross-table (Obs1 post) – Ducrocquet (Obs1 post) |
0.699 |
4 |
Cross-table (Obs2 post) – Ducrocquet (Obs2 post) |
0.223 |
#
Discussion
Comparing the measurement of the alpha angle by two observers using the Ducroquet and cross-table radiographic views, we observed good intraobserver correlation, but low interobserver correlation.
The diagnosis of the subtle changes that may cause early hip coxarthrosis is evolving in the last few years.[15] Radiographs are valuable for the detection of femoral and acetabular morphological changes.[4] [11] [12]
The alpha angle (Nötzli angle) is often used to diagnose pathological deformities of the femoral neck.[6] [8] [12] [13] [16]
There are controversies as to the ideal view for alpha angle measurement. Meyer et al[13] compared 6 radiographic views (anteroposterior, Dunn, Dunn with 45° of flexion, cross-table with 15° of internal rotation, cross-table in neutral rotation, and cross-table with 15° of external rotation). They concluded that the Dunn view at 45° or 90° of flexion or the cross-table view with internal rotation are better at detecting changes in the sphericity of the femoral head-to-neck transition; in addition, the authors noted that the anteroposterior and cross-table views with external rotation are not able to detect these changes.
The Ducroquet view is easy to perform and represents the true profile of the proximal femoral end, perfectly showing the transition between the neck and the femoral head.[11] [12] Moreover, this view is useful for intraoperative control during femoral osteoplasty, since it allows obtaining profile images without moving the fluoroscopy arm.
The cross-table profile technique also provides a true view of the femoral neck; in addition, it allows the visualization of the accessory acetabulum. However, it is technically more demanding because the imaging tube must be mobile. It also requires an orthopedic table that does not interfere with the height of the tube.[11] [12] Many orthopedic centers in Brazil do not have the mobile X-ray equipment or a suitable orthopedic table required for this view.
There was a statistically significant difference (p = 0.00) for the interobserver measurements with both views and at both time points.
The mean measurements of observer 2 were lower compared with all of the measurements from observer 1; this finding may be due to subtle differences in the measurement techniques from both observers.
There was a good intraobserver correlation for both incidences at the 2 time points; moreover, there was no statistically significant difference (p = 0.309, p = 0.611, p = 0.699, p = 0.223) between the measurements obtained in both views.
The analysis of radiographic parameters obtained at different moments has already been reported in the literature.[1] [13] Meyer et al[13] showed that the use of cross-table and Dunn views by positioning limbs at 45° and 90° (similar to the Ducroquet view) resulted in a better reproduction of alpha angle measurements.
In our study, the measurement of the alpha angle was dependent on the observer. However, this disparity usually does not exist when the same observer performs different measures over a given time.
One of the limitations of our work was the difficulty in obtaining cross-table views in obese patients, since, at that time, we only had conventional X-ray equipment. The recent availability of digital X-ray equipment made it easier to obtain these images in these patients. The difficulty in obtaining cross-table views may be due to the standardization of the Ducroquet view in our hospital as the radiographic incidence of choice to visualize the hip profile. Another limitation was the analysis by only two radiologists as observers.
Given these results, we believe that the Ducroquet radiographic view is a good option for alpha angle measurement, and that it can be the profile of choice since it is easily performed during hip arthroscopies without moving the fluoroscopy arm.
#
Conclusion
We conclude that the measurement of the alpha angle using the cross-table or Ducroquet view is equivalent.
#
#
Conflitos de Interesses
Os autores declaram não haver conflitos de interesses.
Acknowledgment
We are grateful to Prof. Daniel K. Scheffer for providing the statistical analysis.
∗ Work performed at the Hip Group, Orthopedics and Traumatology Department, Irmandade Santa Casa de Misericórdia, Faculdade de Ciências Médicas da Santa Casa de São Paulo (FCMSCSP), São Paulo, SP, Brazil.
-
Referências
- 1 Clohisy JC, Carlisle JC, Trousdale R, Kim YJ, Beaule PE, Morgan P. , et al. Radiographic evaluation of the hip has limited reliability. Clin Orthop Relat Res 2009; 467 (03) 666-675
- 2 Fadul DA, Carrino JA. Imaging of femoroacetabular impingement. J Bone Joint Surg Am 2009; 91 (Suppl. 01) 138-143
- 3 Dudda M, Albers C, Mamisch TC, Werlen S, Beck M. Do normal radiographs exclude asphericity of the femoral head-neck junction?. Clin Orthop Relat Res 2009; 467 (03) 651-659
- 4 Tannast M, Siebenrock KA, Anderson SE. Femoroacetabular impingement: radiographic diagnosis--what the radiologist should know. AJR Am J Roentgenol 2007; 188 (06) 1540-1552
- 5 Eijer H, Leunig M, Mahomed MN, Ganz R. Cross- table lateral radiographs for screening of anterior femoral head- neck offset in patients with femoro- acetabular impingement. Hip Int 2001; 11 (01) 37-41
- 6 Neumann M, Cui Q, Siebenrock KA, Beck M. Impingement-free hip motion: the ‘normal’ angle alpha after osteochondroplasty. Clin Orthop Relat Res 2009; 467 (03) 699-703
- 7 Fraitzl CR, Käfer W, Nelitz M, Reichel H. Radiological evidence of femoroacetabular impingement in mild slipped capital femoral epiphysis: a mean follow-up of 14.4 years after pinning in situ. J Bone Joint Surg Br 2007; 89 (12) 1592-1596
- 8 Nötzli HP, Wyss TF, Stoecklin CH, Schmid MR, Treiber K, Hodler J. The contour of the femoral head-neck junction as a predictor for the risk of anterior impingement. J Bone Joint Surg Br 2002; 84 (04) 556-560
- 9 Clohisy JC, Nunley RM, Otto RJ, Schoenecker PL. The frog-leg lateral radiograph accurately visualized hip cam impingement abnormalities. Clin Orthop Relat Res 2007; 462 (462) 115-121
- 10 Ito K, Minka II MA, Leunig M, Werlen S, Ganz R. Femoroacetabular impingement and the cam-effect. A MRI-based quantitative anatomical study of the femoral head-neck offset. J Bone Joint Surg Br 2001; 83 (02) 171-176
- 11 Godefroy D, Chevrot A, Morvan G, Rousselin B, Sarazin L. [Plain films of pelvis]. J Radiol 2008; 89 (5 Pt 2): 679-690 , quiz 691
- 12 Chrétien J. -Lateral views of the hip-. Ann Radiol (Paris) 1997; 40 (01) 5-10
- 13 Meyer DC, Beck M, Ellis T, Ganz R, Leunig M. Comparison of six radiographic projections to assess femoral head/neck asphericity. Clin Orthop Relat Res 2006; 445 (445) 181-185
- 14 Loder RT. Effect of femur position on the angular measurement of slipped capital femoral epiphysis. J Pediatr Orthop 2001; 21 (04) 488-494
- 15 Gosvig KK, Jacobsen S, Palm H, Sonne-Holm S, Magnusson E. A new radiological index for assessing asphericity of the femoral head in cam impingement. J Bone Joint Surg Br 2007; 89 (10) 1309-1316
- 16 Rakhra KS, Sheikh AM, Allen D, Beaulé PE. Comparison of MRI alpha angle measurement planes in femoroacetabular impingement. Clin Orthop Relat Res 2009; 467 (03) 660-665
Endereço para correspondência
-
Referências
- 1 Clohisy JC, Carlisle JC, Trousdale R, Kim YJ, Beaule PE, Morgan P. , et al. Radiographic evaluation of the hip has limited reliability. Clin Orthop Relat Res 2009; 467 (03) 666-675
- 2 Fadul DA, Carrino JA. Imaging of femoroacetabular impingement. J Bone Joint Surg Am 2009; 91 (Suppl. 01) 138-143
- 3 Dudda M, Albers C, Mamisch TC, Werlen S, Beck M. Do normal radiographs exclude asphericity of the femoral head-neck junction?. Clin Orthop Relat Res 2009; 467 (03) 651-659
- 4 Tannast M, Siebenrock KA, Anderson SE. Femoroacetabular impingement: radiographic diagnosis--what the radiologist should know. AJR Am J Roentgenol 2007; 188 (06) 1540-1552
- 5 Eijer H, Leunig M, Mahomed MN, Ganz R. Cross- table lateral radiographs for screening of anterior femoral head- neck offset in patients with femoro- acetabular impingement. Hip Int 2001; 11 (01) 37-41
- 6 Neumann M, Cui Q, Siebenrock KA, Beck M. Impingement-free hip motion: the ‘normal’ angle alpha after osteochondroplasty. Clin Orthop Relat Res 2009; 467 (03) 699-703
- 7 Fraitzl CR, Käfer W, Nelitz M, Reichel H. Radiological evidence of femoroacetabular impingement in mild slipped capital femoral epiphysis: a mean follow-up of 14.4 years after pinning in situ. J Bone Joint Surg Br 2007; 89 (12) 1592-1596
- 8 Nötzli HP, Wyss TF, Stoecklin CH, Schmid MR, Treiber K, Hodler J. The contour of the femoral head-neck junction as a predictor for the risk of anterior impingement. J Bone Joint Surg Br 2002; 84 (04) 556-560
- 9 Clohisy JC, Nunley RM, Otto RJ, Schoenecker PL. The frog-leg lateral radiograph accurately visualized hip cam impingement abnormalities. Clin Orthop Relat Res 2007; 462 (462) 115-121
- 10 Ito K, Minka II MA, Leunig M, Werlen S, Ganz R. Femoroacetabular impingement and the cam-effect. A MRI-based quantitative anatomical study of the femoral head-neck offset. J Bone Joint Surg Br 2001; 83 (02) 171-176
- 11 Godefroy D, Chevrot A, Morvan G, Rousselin B, Sarazin L. [Plain films of pelvis]. J Radiol 2008; 89 (5 Pt 2): 679-690 , quiz 691
- 12 Chrétien J. -Lateral views of the hip-. Ann Radiol (Paris) 1997; 40 (01) 5-10
- 13 Meyer DC, Beck M, Ellis T, Ganz R, Leunig M. Comparison of six radiographic projections to assess femoral head/neck asphericity. Clin Orthop Relat Res 2006; 445 (445) 181-185
- 14 Loder RT. Effect of femur position on the angular measurement of slipped capital femoral epiphysis. J Pediatr Orthop 2001; 21 (04) 488-494
- 15 Gosvig KK, Jacobsen S, Palm H, Sonne-Holm S, Magnusson E. A new radiological index for assessing asphericity of the femoral head in cam impingement. J Bone Joint Surg Br 2007; 89 (10) 1309-1316
- 16 Rakhra KS, Sheikh AM, Allen D, Beaulé PE. Comparison of MRI alpha angle measurement planes in femoroacetabular impingement. Clin Orthop Relat Res 2009; 467 (03) 660-665