Summary

The effectiveness of three commercial bone scintigraphic agents and freshly made stannous chloride in labeling erythrocytes with 99mTc was compared. Our results indicate that tin pyrophosphate is the agent of choice and that it is most effective when injected at least 15 minutes before the 99mTc-per-technetate is administered. This technique of labeling red blood cells in vivo could be applied in performing blood pool studies.

Wir verglichen die Wirksamkeit dreier handelsüblicher Kits für die Knochenszintigraphie und neu hergestellten Zinnchlorids zur Markierung von Erythrozyten mit Tc. Unsere Versuche ergaben, daß Zinnpyrophosphat das am besten geeignete Präparat ist und daß es am besten wirkt, wenn es mindestens 15 Minuten vor der 99mTc-Pertechnat-Gabe injiziert wird. Diese Technik der roten Blutkörperchen-Markierung „in vivo“ könnte bei Blutpooluntersuchungen angewendet werden.

 
  • References

  • 1 Chandler W. M, Shuck L. D. Abnormal 99mTc pertechnetate imaging following stannous pyrophosphate bone imaging. J. Nucl. Med 1975; 16: 518-9.
  • 2 Waker A. G. Effects of 99mTc-Sn bone scan agents on subsequent pertechnetate brain scans. J. Nucl. Med 1975; 16: 579
  • 3 Pavel D. G, Zimmer A. M, Patterson V. N. Blood pool scanning with in vivo labeled 99mTc RBC. Abstract in Annual Spring Meeting Central Chapter Soc. Nucl. Med. Southfield, Mich. March 1976: 12
  • 4 Krishnamurthy G. T, Walsh C. F, Shoop L. E. et al. Comparison of 99mTc polyphosphate and 18F I kinetics. J. Nucl. Med 1974; 15: 832-836.
  • 5 Krishnamurthy G. T, Huebotter R. J, Walsh C. F. et al. Kinetics of 99™Tc labeled pyrophosphate and polyphosphate in man. J. Nucl. Med 1975; 16: 109-115.