Nuklearmedizin 1973; 12(03): 257-265
DOI: 10.1055/s-0038-1624826
Originalarbeiten — Original Articles — Travaux Originaux
Schattauer GmbH

Compartment Analysis of 131I-Iothalamate and Glomerular Filtration in the Rat

Etudes de la distribution de 131I-iothalamate et de la filtration glomérulaire chez le ratCompartment-Analyse des 131I-Iothalamats und glomeruläre Filtration bei Ratten
André F. Henry
1   Orientacion Fisiologia Humana, Departamento de Ciencias Biologicas, Facultad de Farmacia y Bioquimica, U.B.A. and Centro de Medicina Nuclear del Hospital Escuela José de San Martin, U.B.A., C.N.E.A.
,
Alejandro Martinez Seeber
1   Orientacion Fisiologia Humana, Departamento de Ciencias Biologicas, Facultad de Farmacia y Bioquimica, U.B.A. and Centro de Medicina Nuclear del Hospital Escuela José de San Martin, U.B.A., C.N.E.A.
,
Maria I. Sallemi
1   Orientacion Fisiologia Humana, Departamento de Ciencias Biologicas, Facultad de Farmacia y Bioquimica, U.B.A. and Centro de Medicina Nuclear del Hospital Escuela José de San Martin, U.B.A., C.N.E.A.
,
Victorio Pecorini
1   Orientacion Fisiologia Humana, Departamento de Ciencias Biologicas, Facultad de Farmacia y Bioquimica, U.B.A. and Centro de Medicina Nuclear del Hospital Escuela José de San Martin, U.B.A., C.N.E.A.
› Institutsangaben
Weitere Informationen

Publikationsverlauf

Received:09. Juli 1973

Publikationsdatum:
22. Januar 2018 (online)

Preview

Dans le but d’obtenir une méthode permettant la détermination du volume de filtration glomérulaire (GFR) chez des petits animaux sans qu’il soit nécessaire de recueillir les urines, nous avons étudié la distribution et l’excrétion du 131Iiothalamate (IOT) chez le rat. Le volume de distribution théorique (VD) est de 44.49 ± 5 ml/100 gr et le GFR de 0.91 ± 0.09 ml/min/100 gr. Le VD du IOT chez le rat préalablement néphrectomisé est de 24.49 ± ml/100 gr, ce résultat n’est pas significativement différent du VD de l’inuline. Le volume plasmatique mesuré avec du Bleu d’Evans est de 6.49 ± 0.5 ml/100 gr. L’espace interstitiel de l’IOT determiné a partir de la différence entre le VD chez le rat nephrectomisé et son volume plasmatique est de 18 ml/100 gr. La valeur du GFR déterminée par cette méthode est similaire aux résultats obtenus par d’autres procédés, ce qui nous pousse a penser qu’elle peut être d’une certaine utilité.

Summary

The distribution and excretion of 131I-iothalamate (IOT) in rats has been studied as an attempt to find a method which allows the determination of glomerular filtration rate (GFR) without urine collection. The theoretical volume of distribution (VD) was 44.49 ± 5 ml/100 g and the GFR was 0.91 ± 0.09 ml/min/100 g. The VD of IOT in animals previously nephrectomized was 24.49 ± l m l / 100 g without resulting in any statistically significant difference between this value and theVDof inulin. The plasmatic volume, measured with Evans Blue, was 6.49 ± 0.5 ml/100 g. The volume of interstitial IOT considered as the difference between the VD in nephrectomized animals and the plasmatic volume was 18 ml/100 g. The values obtained correlate closely with other procedures so it is considered that this method is of great advantage for measuring of GFR in small animals.

Man studierte die Verteilung und Ausscheidung von 131I-Iothalamat (IOT) bei Ratten, um zu versuchen, eine Methode zu finden, die ohne Urinsammlung, die Bestimmung des Prozentsatzes der glomerulären Filtration (GFR) ermöglichen würde. Das theoretische Verteilungsvolumen (VD) war 44.49 ± 5 ml/100 g und der (GFR) war 0.91 ± 0.09 ml/min/100 g. Das VD von IOT in Tieren, deren Nieren vorher entfernt wurden, war 24.49 ± 1 ml/100 g, ohne daß eine statistisch bedeutende Differenz zwischen diesem Wert und dem VD von Inulin bestand. Das Plasmavolumen, mit Evans-Blau gemessen, war 6.49 ± 0.5ml/100g. Das Volumen von interstitiellem IOT, betrachtet als Differenz zwischen dem VD in Tieren, deren Nieren entfernt wurden, und dem Plasmavolumen, war 18 ml/100 g. Die erhaltenen Werte stimmen ziemlich genau mit den Werten überein, die bei anderen Verfahren erhalten wurden, so daß diese Methode als sehr vorteilhaft für die Messung der GFR bei kleinen Tieren bezeichnet werden kann.