Nuklearmedizin 2006; 45(01): 1-9
DOI: 10.1055/s-0038-1623929
Original Article
Schattauer GmbH

Diagnostic nuclear medicine procedures in Germany between 1996 and 2002

Application frequencies and collective effective dosesNuklearmedizinische Untersuchungen in Deutschland zwischen 1996 und 2002Anwendungshäufigkeiten und kollektiv effektive Dosen
A. Stamm-Meyer
1   Federal Office for Radiation Protection, Department of Radiation Protection and Health, Division of Medical Radiation Hygiene and Dosimetry, Neuherberg, Germany
,
D. Noßke
1   Federal Office for Radiation Protection, Department of Radiation Protection and Health, Division of Medical Radiation Hygiene and Dosimetry, Neuherberg, Germany
,
P. Schnell-Inderst
2   Department of Nuclear Medicine, Ludwig-Maximilian University, Munich, Germany
,
M. Hacker
2   Department of Nuclear Medicine, Ludwig-Maximilian University, Munich, Germany
,
K. Hahn
2   Department of Nuclear Medicine, Ludwig-Maximilian University, Munich, Germany
,
G. Brix
1   Federal Office for Radiation Protection, Department of Radiation Protection and Health, Division of Medical Radiation Hygiene and Dosimetry, Neuherberg, Germany
› Author Affiliations
Further Information

Publication History

Received: 23 June 2005

28 August 2005

Publication Date:
10 January 2018 (online)

Preview

Summary

Aim: Man-made radiation exposure to the German population predominantly results from the medical use of ionizing radiation. It was therefore the aim of the present study, to provide public health information concerning diagnostic nuclear medicine procedures carried out in Germany between 1996 and 2002. Material and methods: Application frequencies for 10 groups of procedures were estimated from official reimbursement data provided by the German health insurance companies. Mean effective doses for these examinations were estimated from data provided by 14 clinics and 10 practices concerning the radiopharmaceuticals in use and the activities administered. Results: During the period 1996-2002, a total of (3.83 ± 0.31) million nuclear medicine procedures were performed in average per year, which corresponds to a mean annual application frequency of approximately 47 examinations per 1 000 inhabitants. More than 90% of the examinations were scintigraphies of the thyroid (37%), skeleton (25%), myocardium (13%), lungs (8%) and kidneys (8%). The averaged collective effective dose was (10.2 ± 1.4) ⋅103 manSv per year, which corresponds to a mean annual per caput effective dose of about (0.12 ± 0.02) mSv. Three types of procedures were responsible for about 80% of the total collective effective dose: scintigraphies of the myocardium (36%), skeleton (33%) and thyroid (10%). Averaged over all procedures carried-out, the mean effective dose per examination was (2.7 ± 0.8) mSv. Conclusion: The average effective dose per inhabitant and year caused by nuclear medicine examinations is markedly lower than that resulting from medical X-ray procedures (0.12 vs. 1.8 mSv). Reduction of patient exposure may be achieved, for example, by replacing 201Tl-labeled radiopharmaceuticals by 99mTc-labeled compounds.

Zusammenfassung

Ziel: Die zivilisatorische Strahlenexposition der Bevölkerung in Deutschland resultiert in der Hauptsache aus medizinischen Strahlenanwendungen. Ziel dieser Arbeit war es, den Beitrag der nuklearmedizinischen Diagnostik in Deutschland während der Jahre 1996 bis 2002 zu ermitteln. Material und Methoden: Für 10 Untersuchungsarten wurden Anwendungshäufigkeiten basierend auf Abrechnungsstatistiken der Krankenversicherungen ermittelt. Mittlere effektive Dosiswerte für diese Untersuchungen wurden aus Angaben von 14 Kliniken und 10 Praxen bezüglich der verwendeten Radiopharmaka und applizierten Aktivitäten abgeschätzt. Ergebnisse: Zwischen 1996 und 2002 wurden in Deutschland im Mittel ca. (3,83 ± 0,31) Millionen Untersuchungen pro Jahr durchgeführt, was einer mittleren jährlichen Anwendungshäufigkeit von ca. 47 Untersuchungen pro 1 000 Einwohner entspricht. Mehr als 90% der Untersuchungen entfielen auf Szintigraphien der Schilddrüse (37%), des Skeletts (25%), des Herzens (13%), der Lunge (8%), und der Nieren (8%). Die kollektive effektive Dosis pro Jahr betrug (10,2 ± 1,4) ⋅103 manSv, was einer mittleren jährlichen effektiven Dosis von ca. (0,12 ± 0,02) mSv pro Einwohner entsprach. Ungefähr 80% der gesamten kollektiven effektiven Dosis wurden durch 3 Untersuchungsarten verursacht: Szintigraphien des Herzens (36%), des Skeletts (33%) und der Schilddrüse (10%). Gemittelt über alle durchgeführten Untersuchungen betrug die mittlere effektive Dosis pro Untersuchung (2.7 ± 0.8) mSv. Schlussfolgerung: Die aus nuklearmedizinischen Untersuchungen resultierende mittlere effektive Dosis pro Einwohner und Jahr ist wesentlich niedriger ist als der Beitrag der Röntgendiagnostik (0,12 mSv vs. 1,8 mSv). Eine Dosisreduktion kann z.B. durch den konsequenten Ersatz von 201Tl-markierten Radiopharmaka durch 99mTc-markierte Verbindungen erreicht werden.