A Pilot Study Evaluating 99mTc-anti-TNF-alpha Scintigraphy in Graves’ Ophtalmopathy Patients with Different Clinical Activity Score

E. dos S. Rebelo Pinto
1   Departamento de Radiologia e Departamento de Clínica Médica, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
,
F. P. P. L. Lopes
1   Departamento de Radiologia e Departamento de Clínica Médica, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
,
S. A. L. de Souza
1   Departamento de Radiologia e Departamento de Clínica Médica, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
,
L. M. B. da Fonseca
1   Departamento de Radiologia e Departamento de Clínica Médica, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
,
M. Vaisman
1   Departamento de Radiologia e Departamento de Clínica Médica, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
,
B. Gutfilen
1   Departamento de Radiologia e Departamento de Clínica Médica, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
,
P. de F. dos Santos Teixeira
1   Departamento de Radiologia e Departamento de Clínica Médica, Faculdade de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
› Author Affiliations
Further Information

Publication History

received 27 December 2012

accepted after second revision 25 June 2013

Publication Date:
05 August 2013 (online)

Preview

Abstract

The present study describes the preliminary results of the use of 99mTc-anti-TNF-α scintigraphy as a new diagnostic approach to evaluate patients presenting with Graves’ ophthalmopathy (GO). Patients (n=25) presenting at different inflammatory stages of GO and 10 healthy volunteers underwent 99mTc-anti-TNF-α scintigraphy. Images were obtained 15 min after the intravenous injection of 370 MBq (10 mCi) 99mTc-anti-TNF-α. Planar images were obtained in a 256×256 matrix (each lasting 5 min) and single photon emission computed tomography (SPECT) scan lasting 13 min. Regions of interest (ROI) were drawn on the orbit and cerebral hemispheres. The uptake of 99m Tc-anti-TNF-α in these regions was compared and positive scintigraphy established when the ROI was >2.5. In addition, uptake for each positive exam was scored as either slight (2.6–5.1), moderate (5.2–7.6), or high (>7.6). In this pilot study, 69 orbits were evaluated (1 patient had only 1 eye), and 27 had a positive CAS (≥3/7). Scintigraphies were positive in 38 orbits. Comparing the results of the exams with CAS, a high sensitivity and negative predictive values were determined for scintigraphy (96.3% and 96.7%, respectively). However, the specificity and the positive predictive values were 71.4% and 68.4%, respectively, with an accuracy of 81.2%. The exclusion of examinations that were slightly positive from the analysis resulted in an improvement in test accuracy (95.5%). The preliminary results suggest that 99mTc-anti-TNF-α scintigraphy is a promising procedure for the evaluation of active orbital inflammation in GO.