RSS-Feed abonnieren
DOI: 10.1055/s-0032-1326186
Bowel preparation for colonoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Guideline
Corresponding author
Publikationsverlauf
Publikationsdatum:
18. Januar 2013 (online)
Background and aim: This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). It addresses the choice amongst regimens available for cleansing the colon in preparation for colonoscopy.
Methods: This Guideline is based on a targeted literature search to evaluate the evidence supporting the use of bowel preparation for colonoscopy. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was adopted to define the strength of recommendation and the quality of evidence.
Results: The main recommendations are as follows. (1) The ESGE recommends a low-fiber diet on the day preceding colonoscopy (weak recommendation, moderate quality evidence). (2) The ESGE recommends a split regimen of 4 L of polyethylene glycol (PEG) solution (or a same-day regimen in the case of afternoon colonoscopy) for routine bowel preparation. A split regimen (or same-day regimen in the case of afternoon colonoscopy) of 2 L PEG plus ascorbate or of sodium picosulphate plus magnesium citrate may be valid alternatives, in particular for elective outpatient colonoscopy (strong recommendation, high quality evidence). In patients with renal failure, PEG is the only recommended bowel preparation. The delay between the last dose of bowel preparation and colonoscopy should be minimized and no longer than 4 hours (strong recommendation, moderate quality evidence). (3) The ESGE advises against the routine use of sodium phosphate for bowel preparation because of safety concerns (strong recommendation, low quality evidence).
#
Keywords
bowel preparation - colonoscopy - PEG - sodium phosphate - diet, colorectal cancer screening - inflammatory bowel disease - magnesium citrate - sodium picosulphateAbbreviations
1. Introduction
Colonoscopy is the current standard method for evaluating the colon. Recent surveys have shown that the proportion of individuals aged 50 years or older who have undergone colonoscopy within the last 10 years is growing and currently ranges from 6 % – 25 % in various European countries to 62 % in the United States [1] [2]. Bowel preparation for colonoscopy is a complex undertaking, involving diet modifications and laxative choice according to patient needs. An adequate level of cleansing is critical for the efficacy of colonoscopy. Two key quality indicators of colonoscopy, cecal intubation rate and polyp detection rate, are associated with the quality of bowel cleansing [3] [4]. An inadequate level of bowel cleansing also results in further costs as the examination has to be re-scheduled or alternative investigations have to be organized [5]. Furthermore, the discomfort and inconvenience of bowel preparation may affect the acceptability and uptake of colonoscopy in screening programs [6].
The aim of this evidence-based and consensus-based Guideline commissioned by the European Society of Gastrointestinal Endoscopy (ESGE) is to provide caregivers with a comprehensive review of the various regimens available and with practical advice for bowel preparation before colonoscopy.
#
2. Methods
The ESGE commissioned this Guideline. The guideline process included meetings, telephone conferences, and online discussions among members of the committee during October 2011 and January 2012. Subgroups were formed, each in charge of a series of clearly defined key questions ([Appendix e1], available online). The committee chairs (C.H., J.M.D.) worked with the subgroup leaders (M.B., M.F.K., M.P., B.R., B.S.) to identify pertinent search terms that always included, as a minimum, “bowel preparation” as well as terms pertinent to specific key questions. Searches were performed in Medline. Articles were first selected by title; their relevance was then confirmed by review of the corresponding manuscripts, and publications with content that was considered irrelevant were excluded. A repository of selected literature was made available to all members of the guideline development group. Evidence tables were generated for each key question, summarizing the level of evidence of the available studies. For important outcomes, articles were individually assessed by using the Grading of Recommendation, Assessment, Development and Evaluation (GRADE) system for grading evidence levels and recommendation strengths [7]. The GRADE system is clinically orientated as the grading of recommendations depends on the balance between benefits and risks or burden of any health intervention ([Appendix e2], available online). The different subgroups developed draft proposals that were presented to the entire group for general discussion during a meeting held in February 2012 (Dusseldorf, Germany). Further details on the methodology of ESGE guidelines have been reported elsewhere [8]. In June 2012, a draft prepared by J.M.D. and C.H. was sent to all group members. After agreement on a final version, the manuscript was submitted to the journal Endoscopy for publication. The journal subjected the manuscript to peer review, and the manuscript was amended to reflect reviewers’ comments. The final revised manuscript was agreed upon by all the authors.
This Guideline was issued in 2013 and will be considered for review in 2016, or sooner if new evidence becomes available. Any updates of the Guideline in the interim period will be noted on the ESGE website: http://www.esge.com/esge-guidelines.html.
#
3. Recommendations and statements
Evidence statements and recommendations are stated in italics, key evidence statements and recommendations are in bold.
The ESGE recommends a low-fiber diet on the day preceding colonoscopy (weak recommendation, moderate quality evidence).
The potential benefit of a restricted diet before colonoscopy has not been well studied but such diets have been used in most studies. In a retrospective cohort study of 789 patients [9], adherence to the prescribed low-residue diet during the 2 days preceding colonoscopy was an independent predictor of adequate bowel preparation. In a subgroup analysis of a randomized controlled trial (RCT) that allocated patients to low-volume vs. high-volume polyethylene glycol (PEG), patients randomized to low-volume (bisacodyl and 2 liters [L] PEG) more frequently had poor colon cleanliness if they were allowed a normal diet compared with clear fluids only (44.0 % vs. 6.8 %, respectively; P < 0.001); no difference was found in patients taking 4 L of PEG [10]. However, this aspect of bowel preparation is likely less important than the timing of bowel preparation as an RCT has found that split-dose 4-L PEG and no dietary restriction provides better quality colon cleansing than single-dose 4-L PEG with a liquid diet on the day preceding colonoscopy [11].
Two RCTs have compared a clear liquid vs. a low-fiber diet on the day preceding colonoscopy in a total of 414 patients taking identical purgatives for bowel preparation [12] [13]. Both RCTs found that a low-fiber diet was better tolerated than a clear liquid diet; furthermore, satisfactory colon cleanliness was more frequent in patients randomized to non-clear-liquid diets compared with a clear liquid diet (in one of the RCTs the difference was statistically significant in the mid colon only) [13].
The ESGE does not make any recommendations regarding the use of low-fiber diet for more than 24 hours prior to the examination (insufficient evidence to make a recommendation).
Some endoscopists routinely prescribe a low-fiber diet during the 3 days preceding colonoscopy rather than on a single day because of the slow transit time in some patients. However, no study has compared the use of a 1-day vs. a 3-day regimen.
The ESGE recommends against the routine use of enemas in addition to oral bowel preparation (strong recommendation, moderate quality evidence).
A single RCT has compared patients who did or did not have an enema routinely added to standard bowel preparation. The addition of an enema did not result in improved bowel cleansing. However, the acceptability to patients of an identical bowel preparation in the future was lower in patients who had received an enema [14]. Another RCT found no significant difference when different purgatives were prescribed in the groups that did or did not receive the enema [15].
The ESGE does not recommend the routine use of prokinetic agents as adjuncts to bowel preparation (weak recommendation, moderate quality evidence).
Several prokinetic agents have been tested in RCTs as adjuncts to bowel preparation:
-
Metoclopramide, domperidone, cisapride and tegaserod did not improve the tolerability of bowel preparation or the quality of bowel cleansing [16] [17] [18] [19] [20].
-
Two other prokinetic agents, mosapride (an agonist for 5-hydroxytryptamine4 [5-HT4] receptors) and itopride (an antagonist for dopamine receptors and acetylcholinesterase) were found to significantly reduce adverse bowel symptoms including nausea, vomiting, bloating, and abdominal pain (the state of bowel cleansing was similar in all groups) [21]. These results, however, should be confirmed by other groups of authors before a recommendation can be made.
The ESGE suggests adding simethicone to standard bowel preparation (weak recommendation, high quality evidence).
Bubbles and foam are frequently encountered during colonoscopy (32 % – 57 % of patients). This may hamper visualization of the mucosa [22] [23]. Simethicone is an inexpensive substance that reduces the surface tension of air bubbles. It is not absorbed into the bloodstream and it is therefore considered safe.
In a meta-analysis [24] of seven RCTs comparing bowel preparation (PEG or oral sodium phosphate [OSP]) with vs. without simethicone [22] [23] [25] [26] [27] [28] [29], the amount of bubbles was more frequently unacceptable in patients who had not received simethicone (odds ratio [OR], 39.3; 95 % confidence interval [95 %CI] 11.4 – 135.9). No difference in colon cleanliness was found. Because bubbles can be removed during colonoscopy, it is uncertain how the addition of simethicone to bowel preparation affects the efficacy of colonoscopy for detecting lesions. Only one of the seven RCTs included in the meta-analysis compared the detection of lesions in patients who had received simethicone or not; it was underpowered to detect such a difference [22].
Dosage of simethicone varied between studies, the most common being 120 – 240 mg or 45 mL of a 30 % solution given with the evening and morning doses of a purgative. A compound preparation of PEG and simethicone is available in some countries.
The ESGE recommends a split regimen of 4 L PEG solution (or a same-day regimen in the case of afternoon colonoscopy) for routine bowel preparation. A split regimen (or same-day regimen in the case of afternoon colonoscopy) of 2 L PEG plus ascorbate or of sodium picosulphate plus magnesium citrate may be valid alternatives, in particular for elective outpatient colonoscopy (strong recommendation, high quality evidence). In patients with renal failure, PEG is the only recommended bowel preparation. The delay between the last dose of bowel preparation and colonoscopy should be minimized and no longer than 4 hours (strong recommendation, moderate quality evidence).
Polyethylene glycol (PEG) vs. oral sodium phosphate (OSP)
Six meta-analyses, published over a 14-year period (1998 – 2012), have compared various purgatives for pre-colonoscopy bowel preparation [30] [31] [32] [33] [34] [35]. They included between eight and 104 controlled studies and all but one [30] included RCTs exclusively. Among five meta-analyses of head-to-head comparisons of PEG vs. OSP [30] [31] [33] [34] [35], three concluded that satisfactory (excellent or good) colon cleansing is significantly less frequent with PEG as compared with OSP (70 % – 77 % vs. 75 % – 82 %) [31] [33] [34]. The two remaining meta-analyses found no statistically significant difference between PEG and OSP for overall colon cleansing [30] [35]. These two meta-analyses included the highest number of studies because one of them was the most recent [35], and the other one was not restricted to RCTs [30]. A sixth meta-analysis has also included trials that were not head-to-head comparisons. Its main finding was that OSP tablets provide a very high proportion of satisfactory colon cleansing (88 %); however no statistically significant difference was found compared with other regimens [32]. Safety concerns prevent us from recommending routine use of OSP (see below). All the meta-analyses found a significant heterogeneity among trials; this is likely explained by various factors, including variations in the timing of bowel preparation, in dietary instructions, in scales used to assess colon cleanliness, and possibly in the use of adjunctive agents.
#
Magnesium citrate with stimulant laxative
In the UK, magnesium citrate is frequently used as a low-volume bowel preparation in combination with a variety of stimulants. Magnesium citrate combined with sodium picosulphate (Picolax or Picoprep) was compared with PEG and OSP in one meta-analysis (six studies, total of 966 patients) [34]. Compared with PEG, magnesium citrate plus sodium picosulphate provided satisfactory colon cleansing in a similar proportion of patients, with less frequent adverse events (mostly nausea, vomiting, abdominal pain, and sleep disturbances; OR 3.82, 95 %CI 1.60 – 9.15) but OSP produced better colon cleansing than magnesium citrate plus sodium picosulphate.
Various preparations containing magnesium have been tested; [Appendix e3] (available online) summarizes eight RCTs that compared such preparations with OSP or PEG in a total of 1780 patients [36] [37] [38] [39] [40] [41] [42] [43]. When the results of all RCTs were pooled, no significant difference was found between the different regimens in terms of colon cleanliness. In those trials comparing magnesium-based bowel preparation with PEG preparation, clinical side-effects were not significantly different but willingness to repeat the same bowel preparation was higher in the magnesium-based group (a single RCT analyzed that outcome) [38]; mucosal inflammation/ulcerations were significantly more frequent with magnesium-based bowel preparation in the single RCT that assessed that outcome [36]. In two single-blinded RCTs, magnesium citrate combined with 2 L PEG provided similar colon cleanliness to 4 L PEG but with higher patient satisfaction and willingness to repeat the same bowel preparation [44] [45].
#
Low-volume PEG
Various combinations of low-volume (2 L) PEG with an additional laxative have been tested; [Appendix e3] (available online) summarizes 11 RCTs that compared such combinations vs. a standard volume of PEG (4 L). Five RCTs (a total of 1997 patients) used a commercially available formulation of PEG with ascorbate (Moviprep; Norgine Pharmaceuticals) [46] [47] [48] [49] [50]. No significant difference was found between the low-volume formulation and 4 L PEG in terms of colon cleanliness for the whole colon. However, cleanliness in the right colon (assessed in a single study) was less frequently satisfactory with 2 L PEG than with 4 L PEG (54 % vs. 82 % of patients, respectively; P < 0.0001) [48]. Of note, cleanliness in the right colon may be particularly important in the screening setting [51] [52]. Willingness to repeat identical bowel preparation was reported in two RCTs; it tended to be higher with the low-volume formulation as compared with the 4-L PEG (73 % vs. 65 %, respectively; P = 0.079) [47] [48]. One of the limitations of these RCTs is that the majority (77.6 %) of patients had elective outpatient colonoscopy, which is a predictor of satisfactory colon cleansing.
The other six RCTs (a total of 1437 patients) used agents other than ascorbate as additional laxatives, including senna, bisacodyl, magnesium, or olive oil [10] [53] [54] [55] [56] [57]. Satisfactory colon cleansing was less frequent with the low-volume PEG vs. the 4-L PEG (61 % vs. 76 %, respectively; P < 0.0001). The RCT that used magnesium or olive oil as additional laxatives suggested that olive oil combined with 2 L PEG provides better cleansing in the right colon than 4 L PEG (no difference was noted in the left colon), as well as higher patient willingness to repeat identical preparation; these results should be taken with caution as only 80 patients were randomized to one of these two regimens [53].
#
Split-dose regimen
In general, split dosing of bowel preparation is recommended: a meta-analysis of five RCTs found that, compared with the administration of the full dose of PEG on the day before colonoscopy, a split-dose regimen of PEG significantly improved the percentage of patients with satisfactory colon cleanliness, significantly increased patient compliance, and significantly decreased nausea [58]. It has also been suggested that more flat polyps are detected with split-dose vs. single-dose bowel preparation but the RCT that found this difference used a variety of purgatives (PEG and OSP) [59].
#
Same-day regimen
Scheduling colonoscopies in afternoon slots facilitates use of same-day preparation. Three RCTs investigating various timings of bowel preparation have shown that: (i) if 4 L PEG is prescribed, taking the whole dose of bowel preparation on the morning of the colonoscopy rather than on the day before colonoscopy provides better colon cleanliness, less sleep disturbance, and less bloating [60] [61], and (ii) if 2 L PEG plus ascorbate is prescribed, patient tolerance (i. e., absence of abdominal pain and of interference with the previous workday, better sleep quality) is increased by taking the whole dose of purgative on the day of colonoscopy rather than in a split-dose regimen (day before and day of colonoscopy); no difference was found in terms of colon cleanliness [62]. A prospective cohort study suggests that similarly, with sodium magnesium citrate plus sodium picosulphate, taking the whole dose of purgative on the day of an afternoon colonoscopy rather than in a split-dose regimen (day before and day of colonoscopy) provides better colon cleansing with fewer side effects, less impact on activities of daily living, and is preferred by patients [63].
#
Timing of colonoscopy
The length of delay between the last dose of bowel preparation and the start of colonoscopy was found to correlate with the quality of colon cleansing in three prospective studies involving 1546 patients in total ([Appendix e3], available online) [49] [64] [65]. Various purgatives and timings of bowel preparation were used in these studies and all of them found that the delay between the last dose of bowel preparation and the start of colonoscopy was shorter in patients with a satisfactory colon cleansing. In one of these studies, it was estimated that for every additional hour that the patient waits between the end of bowel preparation and colonoscopy, the chance of having a good or excellent cleansing in the right colon decreases by up to 10 % [65].
There are practical difficulties with the administration of bowel preparation on the morning of an afternoon list. There are risks of incontinence when traveling to the endoscopy unit and of bronchoaspiration if deep sedation is used [66]. Such concerns should not be overemphasized because two prospective studies (total 589 outpatients) have found no significant difference in the proportions of patients who had bowel movement while traveling to the endoscopy unit if bowel preparation was administered on the day preceding colonoscopy, on the day of colonoscopy, or with split dosing (globally, such incidents occurred in 5 % – 16 % of patients) [59] [67]. Moreover, a survey of 300 individuals showed that, after having been informed about the advantages of split dosing, approximately 80 % of these individuals would be willing to get up during the night to take the second dose of a split-dose bowel preparation before early morning colonoscopy [68]. An RCT that randomized patients scheduled for early morning colonoscopy for single-dose vs. split-dose 4-L PEG found no difference in compliance between these two regimens. Adverse effects (nausea, vomiting, and bloating) were more frequent with the single-dose vs. the split-dose regimen [69]. Patients starting bowel preparation intake at 0500 on the day of colonoscopy usually report no particular difficulties [55] [64]. Finally, the American Society of Anesthesiologists recommends 2 hours as the minimum fast from intake of clear liquids before sedation or anesthesia [70].
#
Other laxatives
Senna and bisacodyl have mainly been used as adjuncts to PEG ([Appendix e3], available online) or to other regimens [54] [57] [71] [72] [73] [74] [75] [76] [77] [78] [79] [80] [81]. Senna has also been shown to be effective when used alone at high doses [74]. However, it appeared to be less effective and tolerable than low-volume PEG preparation, and its use was limited by abdominal cramps [74] [75] [76] [78]. Similarly, high-dose (30 mg) bisacodyl alone has been shown to have a similar effectiveness to PEG, but it was poorly tolerated because of colicky abdominal pain [57] [81]. Mannitol has also been used for bowel preparation; it seems to be as effective and as well tolerated as OSP or PEG [82] [83]. However its use has almost been abandoned because of the explosion risk when diathermy is used during colonoscopy [84].
The ESGE advises against the routine use of oral sodium phosphate for bowel preparation because of safety concerns (strong recommendation, low quality evidence).
The most feared complication following OSP intake is kidney injury. The largest report of kidney injury (21 patients) described the development of acute renal failure within a few weeks after colonoscopy, which modestly improved over time and required renal replacement therapy in four of the patients [85]. A meta-analysis of seven controlled studies (12 168 patients) that compared the effect of OSP vs. another bowel preparation on kidney function found no statistically significant association between OSP and kidney injury [86]. However, these studies were usually not powered to detect rare, serious complications and tended to exclude individuals at risk for complication development by tight control of inclusion criteria. Moreover, between January 2006 and December 2007, 171 cases of renal failure were reported to the United States Food and Drug Administration (FDA) following the use of OSP and 10 following the use of PEG [87]. A retrospective, population-based national analysis in Iceland estimated that the risk of biopsy-proven acute phosphate nephropathy is approximately 1 per 1000 OSP doses sold [88].
Another severe complication of OSP for bowel preparation consists of acute disruption of electrolyte homeostasis, including hyperphosphatemia, hypocalcemia, hypokalemia, and hyper- or hyponatremia. The spectrum of clinical presentation varies from mild symptoms related to hypocalcemia to death [87].
The ESGE suggests that oral sodium phosphate can only be advised in selected cases of specific needs that cannot be met by alternative products (e. g., patient unable to tolerate other agents) and only in individuals assessed by physicians to be at low risk of oral sodium phosphate-related side-effects. An evaluation of the kidney function should be available before prescribing oral sodium phosphate (weak recommendation, low quality evidence). If oral sodium phosphate is used for bowel preparation, 90 mL (solution) or 32 tablets each containing 1.5 g sodium phosphate (48 g total), both in a split-dose regimen is recommended (strong recommendation, high quality evidence).
Several meta-analyses showed that a higher proportion of patients takes the full amount of the prescribed preparation if OSP is prescribed compared with PEG [31] [32] [33] [34]; in the most recent meta-analysis of RCTs, completion rate with OSP was 97 % compared with 90 % with 4 L PEG (it was 98 % with 2 L PEG and 95 % with a split-dose 3-L PEG regimen) [32]. Two meta-analyses also compared the tolerability of PEG vs. OSP [30] [31]; the largest comparison found that, amongst 25 studies that reported tolerability, 14 studies reported that OSP was superior, 10 reported no significant difference and only one reported that PEG was better tolerated [30]. The commonly cited reasons for poor tolerability of PEG were its flavor and the requirement to consume a large volume of liquid (3 – 4 L PEG compared with 1.5 – 2 L for OSP).
Generally accepted contraindications specific to OSP for bowel preparation include, as absolute contraindications, pregnancy, age < 18 years, stage 3 – 5 chronic kidney disease (glomerular filtration rate < 60 mL/min/1.73 m2), inability to maintain adequate fluid intake, pre-existing electrolyte disturbances, ascites, symptomatic congestive heart failure, recent (within < 6 months) symptomatic ischemic heart disease (unstable angina or myocardial infarction). Relative contraindications include active inflammatory bowel disease, parathyroidectomy, and delayed bowel transit [89] [90] [91] [92] [93]. In addition recognized risk factors for acute phosphate nephropathy following the use of OSP include age > 55 years, hypovolemia, baseline kidney disease, bowel obstruction or active colitis as well as intake of drugs that affect renal perfusion or function such as diuretics, angiotensin-converting enzyme (ACE) inhibitors, angiotensin receptor blockers and possibly nonsteroidal anti-inflammatory drugs [89] [90] [91] [92] [93]. Care should be taken in individuals with presumably normal renal function because unrecognized chronic kidney disease may affect a large proportion of older individuals (up to 23 % – 36 % of people aged 65 years or older) [94] [95]. Strategies recommended to prevent acute phosphate nephropathy include: avoidance of OSP in high-risk patients; screening for unrecognized chronic kidney disease and electrolyte imbalances; avoiding dehydration before, during, and after OSP administration; minimizing the dose of OSP; and maintaining a minimum of 12 hours between the administration of the two OSP doses [96]. It is the prescribers’ responsibility to ensure that the patient understands the importance of maintaining an adequate fluid intake [91]. Renal function should be checked as close to the colonoscopy appointment as practically possible, but in any case within 3 months.
If OSP is used, 90 mL solution or 32 tablets each containing 1.5 g sodium phosphate, both in split-dose regimen, is recommended [97] [98] [99] [100] [101].
The ESGE recommends that oral and written information about bowel preparation should be delivered by healthcare professionals. (strong recommendation, moderate quality evidence).
The delivery of both oral and written instructions for bowel preparation, as opposed to written instructions only, has been shown to be an independent predictor of adequate level of cleansing [102]. Nonadherence to preparation instruction appeared to predict a poor level of bowel preparation [103]. Dedicated booklets or visual aids have also been associated with an improvement in the quality of bowel preparation [104] [105].
#
Specific scenarios
In patients with inadequate bowel cleansing, the ESGE suggests the use of endoscopic irrigation pumps or repeating colonoscopy on the following day after additional bowel preparation (weak recommendation, low quality evidence). For the first colonoscopy, the use of models to identify patients at increased risk of inadequate cleansing, with the aim of adapting the bowel preparation is not recommended (insufficient evidence to determine net benefits or risks).
Inadequate colon cleanliness at colonoscopy has been reported in up to 30 % of patients undergoing colonoscopy. Identification of risk factors for inadequate colon cleanliness would have the potential benefit of selecting patients who need a more intensive bowel preparation regimen. Overall, six studies attempted to identify such risk factors by multivariate analysis ([Appendix e4], available online) [102] [106] [107] [108] [109] [110]. Independent risk factors that were identified in at least three of these studies include male gender, inpatient status, and older age. However, a model based on such factors correctly predicted inadequate colon cleansing in only 60 % of patients [102]. Furthermore, no study attempted to apply a different regimen to patients presenting with risk factors for inadequate colon cleanliness. Previous failure to adequately prepare colon cleansing might be a better predictor [111]. Two studies, one retrospective and one prospective, including a total of 318 patients, have analyzed the outcome of a second bowel preparation after inadequate colon cleansing [111] [112]. One of these studies identified colonoscopy on the day following colonoscopy failure due to inadequate colon cleansing as the only independent factor associated with adequate colon cleansing on repeat colonoscopy. The other study lacked a control group and was limited to outpatients; it showed that an “intensive” strategy of bowel preparation (including multiple diet recommendations, bisacodyl, and a split regimen of PEG) was associated with adequate colon cleansing at repeat colonoscopy in 90 % of the cases [112].
Colonoscopy reporting should include an evaluation of the quality of colon cleansing, with the adoption of a validated scale [113]; we reason that adding information in the report about the likely cause of inadequate colon cleansing would also be useful. However, a recent audit in the Netherlands found that no information was stated about adequacy of colon cleansing in 38 % of colonoscopy reports [114].
In a recent randomized study including 42 participants, an irrigation pump (flow rate 650 mL/minute) connected to a disposable catheter inserted through the working channel of a standard colonoscope has been shown to be more effective than the use of syringes for cleansing in patients with suboptimal bowel preparation [115].
The ESGE found insufficient evidence to determine for or against the use of specific regimens in pregnant/breastfeeding women. However, if total colonoscopy is strongly indicated, PEG regimens may be considered, with tapwater enemas preferred in the case of sigmoidoscopy (insufficient evidence to determine net benefits or risks)
Colonoscopy appears feasible and relatively safe in pregnancy when strongly indicated [116] [117]. PEG has not been extensively studied in pregnancy and it is unknown whether it can cause fetal harm; when used for treating constipation during pregnancy, it is considered relatively safe [118] [119] [120]. Because full colonoscopy is rarely indicated during pregnancy, tapwater enemas are recommended as bowel preparation for sigmoidoscopy. No reported series allows any evaluation of the role of bowel preparation during lactation. If bowel preparation is strictly recommended, interrupting breastfeeding during and after bowel preparation may be an option.
The ESGE suggests the use of PEG for bowel preparation in patients affected by or at risk of inflammatory bowel disease. Other agents may cause mucosal abnormalities that mimic inflammatory bowel disease (weak recommendation, moderate quality evidence).
OSP use may be associated with development of colonic mucosal abnormalities [121]. Endoscopically, mucosal lesions, possibly associated with OSP ingestion, were visible in 24 (erosions in 3, aphthoid lesions in 21, and ulcer in 1 patient) out of 730 patients (3.3 %). Lesions were often multiple. The OSP-associated lesions were predominantly located in the distal sigmoid colon and rectum [122]. In a randomized study including 634 patients, preparation-induced mucosal inflammation was 10-fold more frequent with OSP (3.4 %; OR 9.8; P < 0.03) and sodium picosulphate (3.5 %; OR 10; P < 0.03) compared with PEG (0.3 %) [36]. In a study in healthy rats, OSP and PEG caused significantly more colonic mucosal damage compared with a control group and the damage induced by OSP was worse than that caused by PEG [123]. In another study, no significant difference was found either macroscopically or microscopically in terms of the effects of saline, OSP, and PEG solutions in both healthy rats and rats with chemically induced colitis [124].
The ESGE recommends PEG for bowel preparation if urgent colonoscopy is scheduled for lower gastrointestinal bleeding (strong recommendation, moderate quality evidence).
The role of emergency colonoscopy in lower gastrointestinal bleeding remains controversial [125] [126] [127] [128] [129] [130] [131] [132]. Although some studies have shown that urgent examinations performed within 12 – 24 h of admission improve the diagnostic yield and reduce the rebleeding/surgery rates, others have not. Urgent colonoscopy may be defined as an examination performed within 12 – 24 h of admission following a rapid colon purge; it is safe and may facilitate the identification and treatment of bleeding lesions [125] [126] [127] [128] [129] [130] [131]. In a series of 140 patients admitted with acute lower intestinal bleeding, the cecal intubation rate was 41 % without full bowel preparation compared with 74 % in the PEG group [132].
#
#
Use of the guideline
In addition to the legal disclaimer applicable to all ESGE guidelines [8], for the current Guideline, prescribers should adhere to general as well as specific contraindications to bowel preparation (e. g., any oral purgative is contraindicated in the case of ileus, the use of Moviprep is contraindicated in individuals with phenylketonuria, because of the presence of aspartame, and in those with glucose-6-phosphate dehydrogenase deficiency, because of the presence of ascorbate).
ESGE guidelines represent a consensus of best practice based on the available evidence at the time of preparation. They may not apply in all situations and should be interpreted in the light of specific clinical situations and resource availability. Further controlled clinical studies may be needed to clarify aspects of this statement, and revision may be necessary as new data appear. Clinical consideration may justify a course of action at variance to these recommendations. This guideline is intended to be an educational device to provide information that may assist endoscopists in providing care to patients. This guideline is not a rule and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment.
Evidence level |
|
High quality |
One or more well-designed and well-executed randomized controlled trials (RCTs) that yield consistent and directly applicable results. This also means that further research is very unlikely to change our confidence in the estimate of effect. |
Moderate quality |
RCTs with important limitations (i. e. biased assessment of the treatment effect, large loss to follow-up, lack of blinding, unexplained heterogeneity), indirect evidence originating from similar (but not identical) populations of interest, and RCTs with a very small number of participants or observed events. In addition, evidence from well-designed controlled trials without randomization, well-designed cohort or case – control analytic studies, and multiple time series with or without intervention are in this category. It also means that further research will probably have an important effect on our confidence in the estimate of effect and may change the estimate. |
Low quality |
Observational studies would typically be rated as low quality because of the risk for bias.[1] It also means that further research is very likely to have an important effect on our confidence in the estimate of effect and will probably change the estimate. |
Very low quality[2] |
Evidence is conflicting, of poor quality, or lacking, and hence the balance of benefits and harms cannot be determined. Any estimate of effect that is very uncertain as evidence is either unavailable or does not permit a conclusion. |
1 Quality of evidence based on observational studies may be rated as moderate or even high, depending on circumstances under which evidence is obtained from observational studies. Factors that may contribute to upgrading the quality of evidence include a large magnitude of the observed effect, a dose – response association, or the presence of an observed effect when all plausible confounders would decrease the observed effect.
2 Insufficient evidence to determine for or against routinely providing a service.
Strength of recommendation |
|
Strong |
Benefits clearly outweigh risks and burden or vice-versa. Usually stated as “we recommend”. |
Weak |
Benefits closely balanced with risks and burden. Usually stated as “we suggest”. |
RCT, randomized controlled trial; PEG, polyethylene glycol; OSP, oral sodium phosphate
* because the laxative tested is not specified ("laxative kit containing magnesium citrate, oral bisacodyl tablets to be administered on the day prior to colonoscopy, and a bisacodyl suppository to be administered on the day of the procedure").
First author, year |
n |
Study design |
Bowel preparation |
Risk factors |
Hassan, 2012 [102] |
2811 |
Prospective |
PEG/OSP |
Male gender; older age; higher BMI; previous colorectal surgery; cirrhosis; Parkinson disease or diabetes requiring active treatment; positive fecal occult blood test |
Borg, 2009 [106] |
1577 |
Retrospective |
PEG/OSP |
Male gender; inpatient status; BMI ≥ 25 kg/m2; smoking or alcohol consumption; use of antidepressant or narcotic; diabetes mellitus; decreased mental capacity |
Chan, 2011 [107] |
501 |
Prospective |
PEG |
Education level ≤ primary; appointment waiting time > 16 weeks |
Chung, 2009 [108] |
362 |
Prospective |
PEG |
Age > 60 years; diabetes; previous appendectomy, colorectal resection or hysterectomy |
Lebwohl, 2010 [109] |
12430 |
Retrospective |
PEG |
Male gender; inpatient status; age ≥ 70 years; married status; indication for colonoscopy (diarrhea, constipation, abdominal pain, inflammatory bowel disease) |
Ness, 2001 [110] |
649 |
Prospective |
PEG/OSP |
Male gender; inpatient status; history of cirrhosis, stroke or dementia; indication for colonoscopy (constipation, history of polyps) |
PEG, polyethylene glycol; OSP, oral sodium phosphate; BMI, body mass index
#
#
Competing interests: Michael Bretthauer has received bowel preparation materials free of charge for use in clinical trials, from Falk Pharma and Ferring. Dr Rembacken has taken part in Advisory Board Meetings of Ferring and Ibsen. No competing interest has been reported by the other authors.
-
References
- 1 Stock C, Brenner H. Utilization of lower gastrointestinal endoscopy and fecal occult blood test in 11 European countries: evidence from the Survey of Health, Aging and Retirement in Europe (SHARE). Endoscopy 2010; 42: 546-556
- 2 Centers for Disease Control and Prevention. Vital signs: Colorectal Cancer Screening, Incidence, and Mortality – United States, 2002–2010. MMWR Morb Mortal Wkly Rep 2011; 60: 884-890
- 3 Harewood GC, Sharma VK, de Garmo P. Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia. Gastrointest Endosc 2003; 58: 76-79
- 4 Froehlich F, Wietlisbach V, Gonvers J-J et al. Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European multicenter study. Gastrointest Endosc 2005; 61: 378-384
- 5 Rex DK, Imperiale TF, Latinovich DR et al. Impact of bowel preparation on efficiency and cost of colonoscopy. Am J Gastroenterol 2002; 97: 1696-1700
- 6 Senore C, Ederle A, Fantin A et al. Acceptability and side-effects of colonoscopy and sigmoidoscopy in a screening setting. J Med Screen 2011; 18: 128-134
- 7 Atkins D, Best D, Briss PA et al. Grading quality of evidence and strength of recommendations. BMJ 2004; 328: 1490
- 8 Dumonceau J-M, Hassan C, Riphaus A et al. European Society of Gastrointestinal Endoscopy (ESGE) Guideline Development Policy. Endoscopy 2012; 44: 626-629
- 9 Wu K-L, Rayner CK, Chuah S-K et al. Impact of low-residue diet on bowel preparation for colonoscopy. Dis Colon Rectum 2011; 54: 107-112
- 10 Adams WJ, Meagher AP, Lubowski DZ et al. Bisacodyl reduces the volume of polyethylene glycol solution required for bowel preparation. Dis Colon Rectum 1994; 37: 229-233 discussion 233–224
- 11 Aoun E, Abdul-Baki H, Azar C et al. A randomized single-blind trial of split-dose PEG-electrolyte solution without dietary restriction compared with whole dose PEG-electrolyte solution with dietary restriction for colonoscopy preparation. Gastrointest Endosc 2005; 62: 213-218
- 12 Soweid AM, Kobeissy AA, Jamali FR et al. A randomized single-blind trial of standard diet versus fiber-free diet with polyethylene glycol electrolyte solution for colonoscopy preparation. Endoscopy 2010; 42: 633-638
- 13 Park DI, Park SH, Lee SK et al. Efficacy of prepackaged, low residual test meals with 4L polyethylene glycol versus a clear liquid diet with 4L polyethylene glycol bowel preparation: a randomized trial. J Gastroenterol Hepatol 2009; 24: 988-991
- 14 Lever EL, Walter MH, Condon SC et al. Addition of enemas to oral lavage preparation for colonoscopy is not necessary. Gastrointest Endosc 1992; 38: 369-372
- 15 Børkje B, Pedersen R, Lund GM et al. Effectiveness and acceptability of three bowel cleansing regimens. Scand J Gastroenterol 1991; 26: 162-166
- 16 Golub RW, Kerner BA, Wise WE et al. Colonoscopic bowel preparations – which one? A blinded, prospective, randomized trial. Dis Colon Rectum 1995; 38: 594-599
- 17 Tasci I, Altinli E, Sirin F. Bowel cleansing for diagnostic colonoscopy: which method is preferable? Istanbul experience. Tech Coloproctol 2003; 7: 18-21
- 18 Martínek J, Hess J, Delarive J et al. Cisapride does not improve precolonoscopy bowel preparation with either sodium phosphate or polyethylene glycol electrolyte lavage. Gastrointest Endosc 2001; 54: 180-185
- 19 Katsinelos P, Pilpilidis I, Paroutoglou G et al. The administration of cisapride as an adjuvant to PEG-electrolyte solution for colonic cleansing: a double-blind randomized study. Hepatogastroenterology 2005; 52: 441-443
- 20 Sanaka MR, Super DM, Mullen KD et al. Use of tegaserod along with polyethylene glycol electrolyte solution for colonoscopy bowel preparation: a prospective, randomized, double-blind, placebo-controlled study. Aliment Pharmacol Ther 2006; 23: 669-674
- 21 Mishima Y, Amano Y, Okita K et al. Efficacy of prokinetic agents in improving bowel preparation for colonoscopy. Digestion 2008; 77: 166-172
- 22 Tongprasert S, Sobhonslidsuk A, Rattanasiri S. Improving quality of colonoscopy by adding simethicone to sodium phosphate bowel preparation. World J Gastroenterol 2009; 15: 3032-3037
- 23 Shaver WA, Storms P, Peterson WL. Improvement of oral colonic lavage with supplemental simethicone. Dig Dis Sci 1988; 33: 185-188
- 24 Wu L, Cao Y, Liao C et al. Systematic review and meta-analysis of randomized controlled trials of Simethicone for gastrointestinal endoscopic visibility. Scand J Gastroenterol 2011; 46: 227-235
- 25 Altintaş E, Uçbilek E, Sezgin O et al. Alverine citrate plus simethicone reduces cecal intubation time in colonoscopy – a randomized study. Turk J Gastroenterol 2008; 19: 174-179
- 26 Lazzaroni M, Petrillo M, Desideri S et al. Efficacy and tolerability of polyethylene glycol-electrolyte lavage solution with and without simethicone in the preparation of patients with inflammatory bowel disease for colonoscopy. Aliment Pharmacol Ther 1993; 7: 655-659
- 27 McNally PR, Maydonovitch CL, Wong RK. The effect of simethicone on colonic visibility after night-prior colonic lavage. A double-blind randomized study. J Clin Gastroenterol 1989; 11: 650-652
- 28 McNally PR, Maydonovitch CL, Wong RK. The effectiveness of simethicone in improving visibility during colonoscopy: a double-blind randomized study. Gastrointest Endosc 1988; 34: 255-258
- 29 Sudduth RH, DeAngelis S, Sherman KE et al. The effectiveness of simethicone in improving visibility during colonoscopy when given with a sodium phosphate solution: a double-bind randomized study. Gastrointest Endosc 1995; 42: 413-415
- 30 Belsey J, Epstein O, Heresbach D. Systematic review: oral bowel preparation for colonoscopy. Aliment Pharmacol Ther 2007; 25: 373-384
- 31 Hsu CW, Imperiale TF. Meta-analysis and cost comparison of polyethylene glycol lavage versus sodium phosphate for colonoscopy preparation. Gastrointest Endosc 1998; 48: 276-282
- 32 Juluri R, Eckert G, Imperiale TF. Polyethylene glycol vs. sodium phosphate for bowel preparation: A treatment arm meta-analysis of randomized controlled trials. BMC Gastroenterology 2011; 11: 38
- 33 Juluri R, Eckert G, Imperiale TF. Meta-analysis: randomized controlled trials of 4-L polyethylene glycol and sodium phosphate solution as bowel preparation for colonoscopy. Aliment Pharmacol Ther 2010; 32: 171-181
- 34 Tan JJY, Tjandra JJ. Which is the optimal bowel preparation for colonoscopy – a meta-analysis. Colorectal Dis 2006; 8: 247-258
- 35 Belsey J, Crosta C, Epstein O et al. Meta-analysis: the relative efficacy of oral bowel preparations for colonoscopy 1985–2010. Aliment Pharmacol Ther 2012; 35: 222-237
- 36 Lawrance IC, Willert RP, Murray K. Bowel cleansing for colonoscopy: prospective randomized assessment of efficacy and of induced mucosal abnormality with three preparation agents. Endoscopy 2011; 43: 412-418 Epub 2011 May 4
- 37 Renaut AJ, Raniga S, Frizelle FA et al. A randomized controlled trial comparing the efficacy and acceptability of phospo-soda buffered saline (Fleet®) with sodium picosulphate/magnesium citrate (Picoprep®) in the preparation of patients for colonoscopy. Colorectal Dis 2008; 10: 503-505
- 38 Worthington J, Thyssen M, Chapman G et al. A randomised controlled trial of a new 2 litre polyethylene glycol solution versus sodium picosulphate + magnesium citrate solution for bowel cleansing prior to colonoscopy. Curr Med Res Opin 2008; 24: 481-488
- 39 Tjandra JJ, Chan M, Tagkalidis PP. Oral sodium phosphate (Fleet) is a superior colonoscopy preparation to Picopre (sodium picosulfate-based preparation). Dis Colon Rectum 2006; 49: 616-620
- 40 Schmidt L-M, Williams P, King D et al. Picoprep-3 is a superior colonoscopy preparation to Fleet: a randomized, controlled trial comparing the two bowel preparations. Dis Colon Rectum 2004; 47: 238-242
- 41 Berkelhammer C, Ekambaram A, Silva RG et al. Low-volume oral colonoscopy bowel preparation: sodium phosphate and magnesium citrate. Gastrointest Endosc 2002; 56: 89-94
- 42 Regev A, Fraser G, Delpre G et al. Comparison of two bowel preparations for colonoscopy: sodium picosulphate with magnesium citrate versus sulphate-free polyethylene glycol lavage solution. Am J Gastroenterol 1998; 93: 1478-1482
- 43 Hamilton D, Mulcahy D, Walsh D et al. Sodium picosulphate compared with polyethylene glycol solution for large bowel lavage: a prospective randomised trial. Br J Clin Pract 1996; 50: 73-75
- 44 Park SS, Sinn DH, Kim Y-H et al. Efficacy and tolerability of split-dose magnesium citrate: low-volume (2 liters) polyethylene glycol vs. single- or split-dose polyethylene glycol bowel preparation for morning colonoscopy. Am J Gastroenterol 2010; 105: 1319-1326
- 45 Sharma VK, Chockalingham SK, Ugheoke EA et al. Prospective, randomized, controlled comparison of the use of polyethylene glycol electrolyte lavage solution in four-liter versus two-liter volumes and pretreatment with either magnesium citrate or bisacodyl for colonoscopy preparation. Gastrointest Endosc 1998; 47: 167-171
- 46 Jansen SV, Goedhard JG, Winkens B et al. Preparation before colonoscopy: a randomized controlled trial comparing different regimes. Eur J Gastroenterol Hepatol 2011; 23: 897-902
- 47 Pontone S. Low-volume plus ascorbic acid vs high-volume plus simethicone bowel preparation before colonoscopy. World J Gastroenterol 2011; 17: 4689-4695
- 48 Corporaal S, Kleibeuker JH, Koornstra JJ. Low-volume PEG plus ascorbic acid versus high-volume PEG as bowel preparation for colonoscopy. Scand J Gastroenterol 2010; 45: 1380-1386
- 49 Marmo R, Rotondano G, Riccio G et al. Effective bowel cleansing before colonoscopy: a randomized study of split-dosage versus non-split dosage regimens of high-volume versus low-volume polyethylene glycol solutions. Gastrointest Endosc 2010; 72: 313-320
- 50 Ell C, Fischbach W, Bronisch H-J et al. Randomized trial of low-volume PEG solution versus standard PEG + electrolytes for bowel cleansing before colonoscopy. Am J Gastroenterol 2008; 103: 883-893
- 51 Singh H, Turner D, Xue L et al. Risk of developing colorectal cancer following a negative colonoscopy examination: evidence for a 10-year interval between colonoscopies. JAMA 2006; 295: 2366-2373
- 52 Baxter NN, Goldwasser MA, Paszat LF et al. Association of colonoscopy and death from colorectal cancer. Ann Intern Med 2009; 150: 1-8
- 53 Abut E, Guveli H, Yasar B et al. Administration of olive oil followed by a low volume of polyethylene glycol-electrolyte lavage solution improves patient satisfaction with right-side colonic cleansing over administration of the conventional volume of polyethylene glycol-electrolyte lavage solution for colonoscopy preparation. Gastrointest Endosc 2009; 70: 515-521
- 54 Haapamäki MM, Lindström M, Sandzén B. Low-volume bowel preparation is inferior to standard 4 1 polyethylene glycol. Surg Endosc 2011; 25: 897-901
- 55 Enestvedt BK, Fennerty MB, Eisen GM. Randomised clinical trial: MiraLAX vs. Golytely – a controlled study of efficacy and patient tolerability in bowel preparation for colonoscopy. Aliment Pharmacol Ther 2011; 33: 33-40
- 56 Hookey LC, Depew WT, Vanner SJ. Combined low volume polyethylene glycol solution plus stimulant laxatives versus standard volume polyethylene glycol solution: a prospective, randomized study of colon cleansing before colonoscopy. Can J Gastroenterol 2006; 20: 101-105
- 57 DiPalma JA, Mcgowan J, Cleveland MV. Clinical trial: an efficacy evaluation of reduced bisacodyl given as part of a polyethylene glycol electrolyte solution preparation prior to colonoscopy. Aliment Pharmacol Ther 2007; 26: 1113-1119
- 58 Kilgore TW, Abdinoor AA, Szary NM et al. Bowel preparation with split-dose polyethylene glycol before colonoscopy: a meta-analysis of randomized controlled trials. Gastrointest Endosc 2011; 73: 1240-1245
- 59 Parra-Blanco A, Nicolas-Perez D, Gimeno-Garcia A et al. The timing of bowel preparation before colonoscopy determines the quality of cleansing, and is a significant factor contributing to the detection of flat lesions: a randomized study. World J Gastroenterol 2006; 12: 6161-6166
- 60 Church JM. Effectiveness of polyethylene glycol antegrade gut lavage bowel preparation for colonoscopy – timing is the key!. Dis Colon Rectum 1998; 41: 1223-1225
- 61 Varughese S, Kumar AR, George A et al. Morning-only one-gallon polyethylene glycol improves bowel cleansing for afternoon colonoscopies: a randomized endoscopist-blinded prospective study. Am J Gastroenterol 2010; 105: 2368-2374
- 62 Matro R, Shnitser A, Spodik M et al. Efficacy of morning-only compared with split-dose polyethylene glycol electrolyte solution for afternoon colonoscopy: a randomized controlled single-blind study. Am J Gastroenterol 2010; 105: 1954-1961
- 63 Longcroft-Wheaton G, Bhandari P. Same-day bowel cleansing regimen is superior to a split-dose regimen over 2 days for afternoon colonoscopy: results from a large prospective series. J Clin Gastroenterol 2012; 46: 57-61
- 64 Eun CS, Han DS, Hyun YS et al. The timing of bowel preparation is more important than the timing of colonoscopy in determining the quality of bowel cleansing. Dig Dis Sci 2011; 56: 539-544
- 65 Siddiqui AA, Yang K, Spechler SJ et al. Duration of the interval between the completion of bowel preparation and the start of colonoscopy predicts bowel-preparation quality. Gastrointest Endosc 2009; 69: 700-706
- 66 Huffman M, Unger RZ, Thatikonda C et al. Split-dose bowel preparation for colonoscopy and residual gastric fluid volume: an observational study. Gastrointest Endosc 2010; 72: 516-522
- 67 Khan MA, Piotrowski Z, Brown MD. Patient acceptance, convenience, and efficacy of single-dose versus split-dose colonoscopy bowel preparation. J Clin Gastroenterol 2010; 44: 310-311
- 68 Unger RZ, Amstutz SP, Seo DH et al. Willingness to undergo split-dose bowel preparation for colonoscopy and compliance with split-dose instructions. Dig Dis Sci 2010; 55: 2030-2034
- 69 Park JS, Sohn CI, Hwang SJ et al. Quality and effect of single dose versus split dose of polyethylene glycol bowel preparation for early-morning colonoscopy. Endoscopy 2007; 39: 616-619
- 70 Committee on Standards and Practice Parameters, American Society of Anesthesiologists. Practice guidelines for preoperative fasting and the use of pharmacologic agents to reduce the risk of pulmonary aspiration: application to healthy patients undergoing elective procedures: An updated report by the American Society of Anesthesiologists Committee on Standards and Practice Parameters. Anesthesiology 2011; 114: 495-511
- 71 Vradelis S, Kalaitzakis E, Sharifi Y et al. Addition of senna improves quality of colonoscopy preparation with magnesium citrate. World J Gastroenterol 2009; 15: 1759-1763
- 72 Ziegenhagen DJ, Zehnter E, Tacke W et al. Addition of senna improves colonoscopy preparation with lavage: a prospective randomized trial. Gastrointest Endosc 1991; 37: 547-549
- 73 Ziegenhagen DJ, Zehnter E, Tacke W et al. Senna vs. bisacodyl in addition to Golytely lavage for colonoscopy preparation – a prospective randomized trial. Z Gastroenterol 1992; 30: 17-19
- 74 Amato A, Radaelli F, Paggi S et al. Half doses of PEG-ES and senna vs. high-dose senna for bowel cleansing before colonoscopy: a randomized, investigator-blinded trial. Am J Gastroenterol 2010; 105: 675-681
- 75 Radaelli F, Meucci G, Imperiali G et al. High-dose senna compared with conventional PEG-ES lavage as bowel preparation for elective colonoscopy: a prospective, randomized, investigator-blinded trial. Am J Gastroenterol 2005; 100: 2674-2680
- 76 Unal S, Doğan UB, Oztürk Z et al. A randomized prospective trial comparing 45 and 90-ml oral sodium phosphate with X-Prep in the preparation of patients for colonoscopy. Acta Gastroenterol Belg 1998; 61: 281-284
- 77 Kositchaiwat S, Suwanthanmma W, Suvikapakornkul R et al. Comparative study of two bowel preparation regimens for colonoscopy: senna tablets vs sodium phosphate solution. World J Gastroenterol 2006; 12: 5536-5539
- 78 Hangartner PJ, Münch R, Meier J et al. Comparison of three colon cleansing methods: evaluation of a randomized clinical trial with 300 ambulatory patients. Endoscopy 1989; 21: 272-275
- 79 Chen T-A, Wong H-Y, Lin C-K et al. High-dose bisacodyl plus water lavage compared with oral sodium phosphate as bowel preparation for outpatient colonoscopy. J Chin Med Assoc 2009; 72: 402-407
- 80 Rasmussen M, Bohlbro K, Qvist N. Oral sodium phosphate compared with water enemas combined with bisacodyl as bowel preparation for elective colonoscopy. Scand J Gastroenterol 2003; 38: 1090-1094
- 81 Wang H-S, Lin J-K. A randomized prospective trial of bowel preparation for colonoscopy with Fortrans compared with bisacodyl. J Chin Med Assoc 2003; 66: 364-369
- 82 Chacaltana Mendoza A, Rodríguez Ulloa C. [Comparative study between manitol 10% and polyethyleneglycol [corrected] in colonoscopic preparation in inpatients of FAP Central Hospital]. Rev Gastroenterol Peru 2008; 28: 125-132
- 83 Habr-Gama A, Bringel RW, Nahas SC et al. Bowel preparation for colonoscopy: comparison of mannitol and sodium phosphate. Results of a prospective randomized study. Rev Hosp Clin Fac Med Sao Paulo 1999; 54: 187-192
- 84 Rey JF, Beilenhoff U, Neumann CS et al. European Society of Gastrointestinal Endoscopy (ESGE) guideline: the use of electrosurgical units. Endoscopy 2010; 42: 764-772
- 85 Markowitz GS, Stokes MB, Radhakrishnan J et al. Acute phosphate nephropathy following oral sodium phosphate bowel purgative: an underrecognized cause of chronic renal failure. J Am Soc Nephrol 2005; 16: 3389-3396
- 86 Brunelli SM. Association between oral sodium phosphate bowel preparations and kidney injury: a systematic review and meta-analysis. Am J Kidney Dis 2009; 53: 448-456
- 87 Belsey J, Epstein O, Heresbach D. Systematic review: adverse event reports for oral sodium phosphate and polyethylene glycol. Aliment Pharmacol Ther 2009; 29: 15-28
- 88 Pálmadóttir VK, Gudmundsson H, Hardarson S et al. Incidence and outcome of acute phosphate nephropathy in Iceland. PLoS One 2010; 5: e13484
- 89 Hookey LC, Vanner S. Recognizing the clinical contraindications to the use of oral sodium phosphate for colon cleansing: a case study. Can J Gastroenterol 2004; 18: 455-458
- 90 Wexner SD, Beck DE, Baron TH et al. A consensus document on bowel preparation before colonoscopy: prepared by a task force from the American Society of Colon and Rectal Surgeons (ASCRS), the American Society for Gastrointestinal Endoscopy (ASGE), and the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES). Gastrointest Endosc 2006; 63: 894-909
- 91 Balaban DH. Guidelines for the safe and effective use of sodium phosphate solution for bowel cleansing prior to colonoscopy. Gastroenterol Nurs 2008; 31: 327-334 ; quiz 334–325
- 92 Rex DK, Vanner SJ. Colon cleansing before colonoscopy: does oral sodium phosphate solution still make sense?. Can J Gastroenterol 2009; 23: 210-214
- 93 Marshall JB, Pineda JJ, Barthel JS et al. Prospective, randomized trial comparing sodium phosphate solution with polyethylene glycol-electrolyte lavage for colonoscopy preparation. Gastrointest Endosc 1993; 39: 631-634
- 94 Zhang Q-L, Rothenbacher D. Prevalence of chronic kidney disease in population-based studies: systematic review. BMC Public Health 2008; 8: 117
- 95 Russmann S, Lamerato L, Marfatia A et al. Risk of impaired renal function after colonoscopy: a cohort study in patients receiving either oral sodium phosphate or polyethylene glycol. Am J Gastroenterol 2007; 102: 2655-2663
- 96 Markowitz GS, Perazella MA. Acute phosphate nephropathy. Kidney Int 2009; 76: 1027-1034
- 97 Law W-L, Choi H-K, Chu K-W et al. Bowel preparation for colonoscopy: a randomized controlled trial comparing polyethylene glycol solution, one dose and two doses of oral sodium phosphate solution. Asian J Surg 2004; 27: 120-124
- 98 Malik P, Balaban DH, Thompson WO et al. Randomized study comparing two regimens of oral sodium phosphates solution versus low-dose polyethylene glycol and bisacodyl. Dig Dis Sci 2009; 54: 833-841
- 99 Rex DK, Schwartz H, Goldstein M et al. Safety and colon-cleansing efficacy of a new residue-free formulation of sodium phosphate tablets. Am J Gastroenterol 2006; 101: 2594-2604
- 100 Wruble L, Demicco M, Medoff J et al. Residue-free sodium phosphate tablets (OsmoPrep) versus Visicol for colon cleansing: a randomized, investigator-blinded trial. Gastrointest Endosc 2007; 65: 660-670
- 101 Frommer D. Cleansing ability and tolerance of three bowel preparations for colonoscopy. Dis Colon Rectum 1997; 40: 100-104
- 102 Hassan C, Fuccio L, Bruno M et al. A predictive model identifies patients most likely to have inadequate bowel preparation for colonoscopy. Clin Gastroenterol Hepatol 2012; 10: 501-506
- 103 Chan WK, Saravanan A, Manikam J et al. Appointment waiting times and education level influence the quality of bowel preparation in adult patients undergoing colonoscopy. BMC Gastroenterol 2011; 11: 86
- 104 Tae JW, Lee JC, Hong SJ et al. Impact of patient education with cartoon visual aids on the quality of bowel preparation for colonoscopy. Gastrointest Endosc 2012; 76: 804-11
- 105 Spiegel BM, Talley J, Shekelle P et al. Development and validation of a novel patient educational booklet to enhance colonoscopy preparation. Am J Gastroenterol 2011; 106: 875-883
- 106 Borg BB, Gupta NK, Zuckerman GR et al. Impact of obesity on bowel preparation for colonoscopy. Clin Gastroenterol Hepatol 2009; 7: 670-675
- 107 Chan W-K, Saravanan A, Manikam J et al. Appointment waiting times and education level influence the quality of bowel preparation in adult patients undergoing colonoscopy. BMC Gastroenterol 2011; 11: 86
- 108 Chung YW, Han DS, Park KH et al. Patient factors predictive of inadequate bowel preparation using polyethylene glycol: a prospective study in Korea. J Clin Gastroenterol 2009; 43: 448-452
- 109 Lebwohl B, Wang TC, Neugut AI. Socioeconomic and other predictors of colonoscopy preparation quality. Dig Dis Sci 2010; 55: 2014-2020
- 110 Ness RM, Manam R, Hoen H et al. Predictors of inadequate bowel preparation for colonoscopy. Am J Gastroenterol 2001; 96: 1797-1802
- 111 Ben-Horin S, Bar-Meir S, Avidan B. The outcome of a second preparation for colonoscopy after preparation failure in the first procedure. Gastrointest Endosc 2009; 69: 626-630
- 112 Ibáñez M, Parra-Blanco A, Zaballa P et al. Usefulness of an intensive bowel cleansing strategy for repeat colonoscopy after preparation failure. Dis Colon Rectum 2011; 54: 1578-1584
- 113 Lieberman D, Nadel M, Smith RA et al. Standardized colonoscopy reporting and data system: report of the Quality Assurance Task Group of the National Colorectal Cancer Roundtable. Gastrointest Endosc 2007; 65: 757-766
- 114 de Jonge V, Sint Nicolaas J, Cahen DL et al. Quality evaluation of colonoscopy reporting and colonoscopy performance in daily clinical practice. Gastrointest Endosc 2012; 75: 98-106
- 115 Rigaux J, Juriens I, Devière J. A novel system for the improvement of colonic cleansing during colonoscopy. Endoscopy 2012; 44: 703-706
- 116 Cappell MS, Colon VJ, Sidhom OA. A study at 10 medical centers of the safety and efficacy of 48 flexible sigmoidoscopies and 8 colonoscopies during pregnancy with follow-up of fetal outcome and with comparison to control groups. Dig Dis Sci 1996; 41: 2353-2361
- 117 Cappell MS, Fox SR, Gorrepati N. Safety and efficacy of colonoscopy during pregnancy: an analysis of pregnancy outcome in 20 patients. J Reprod Med 2010; 55: 115-123
- 118 Briggs GG, Freeman RK, Yaffe SJ. Drugs in pregnancy and lactation: a reference guide to fetal and neonatal risk. 9th. edn. Philadelphia: Lippincott Williams & Wilkins; 2011
- 119 Nardulli G, Limongi F, Sue G et al. [Use of polyethylene glycol in the treatment of puerperal constipation]. GEN 1995; 49: 224-226
- 120 Vinod J, Bonheur J, Korelitz BI et al. Choice of laxatives and colonoscopic preparation in pregnant patients from the viewpoint of obstetricians and gastroenterologists. World J Gastroenterol 2007; 13: 6549-6552
- 121 Atkinson RJ, Save V, Hunter JO. Colonic ulceration after sodium phosphate bowel preparation. Am J Gastroenterol 2005; 100: 2603-2605
- 122 Rejchrt S, Bures J, Siroký M et al. A prospective, observational study of colonic mucosal abnormalities associated with orally administered sodium phosphate for colon cleansing before colonoscopy. Gastrointest Endosc 2004; 59: 651-654
- 123 Coskun A, Uzunkoy A, Duzgun SA et al. Experimental sodium phosphate and polyethylene glycol induce colonic tissue damage and oxidative stress. Br J Surg 2001; 88: 85-89
- 124 Erdogan B, Isiksoy S, Dundar E et al. The effects of sodium phosphate and polyethylene glycol-electrolyte bowel preparation solutions on 2,4,6-trinitrobenzenesulfonic acid-induced colitis in the rat. Exp Toxicol Pathol 2003; 55: 213-220
- 125 Colacchio TA, Forde KA, Patsos TJ et al. Impact of modern diagnostic methods on the management of active rectal bleeding. Ten year experience. Am J Surg 1982; 143: 607-610
- 126 Das A, Ben-Menachem T, Cooper GS et al. Prediction of outcome in acute lower-gastrointestinal haemorrhage based on an artificial neural network: internal and external validation of a predictive model. Lancet 2003; 362: 1261-1266
- 127 Green BT, Rockey DC, Portwood G et al. Urgent colonoscopy for evaluation and management of acute lower gastrointestinal hemorrhage: a randomized controlled trial. Am J Gastroenterol 2005; 100: 2395-2402
- 128 Jensen DM, Machicado GA, Jutabha R et al. Urgent colonoscopy for the diagnosis and treatment of severe diverticular hemorrhage. N Engl J Med 2000; 342: 78-82
- 129 Jensen DM, Machicado GA. Diagnosis and treatment of severe hematochezia. The role of urgent colonoscopy after purge. Gastroenterology 1988; 95: 1569-1574
- 130 Laine L, Shah A. Randomized trial of urgent vs. elective colonoscopy in patients hospitalized with lower GI bleeding. Am J Gastroenterol 2010; 105: 2636-2641 quiz 2642
- 131 Lanas A, García-Rodríguez LA, Polo-Tomás M et al. Time trends and impact of upper and lower gastrointestinal bleeding and perforation in clinical practice. Am J Gastroenterol 2009; 104: 1633-1641
- 132 Saito K, Inamori M, Sekino Y et al. Management of acute lower intestinal bleeding: what bowel preparation should be required for urgent colonoscopy?. Hepatocastroenterology 2009; 56: 1331-1334
Corresponding author
-
References
- 1 Stock C, Brenner H. Utilization of lower gastrointestinal endoscopy and fecal occult blood test in 11 European countries: evidence from the Survey of Health, Aging and Retirement in Europe (SHARE). Endoscopy 2010; 42: 546-556
- 2 Centers for Disease Control and Prevention. Vital signs: Colorectal Cancer Screening, Incidence, and Mortality – United States, 2002–2010. MMWR Morb Mortal Wkly Rep 2011; 60: 884-890
- 3 Harewood GC, Sharma VK, de Garmo P. Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia. Gastrointest Endosc 2003; 58: 76-79
- 4 Froehlich F, Wietlisbach V, Gonvers J-J et al. Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European multicenter study. Gastrointest Endosc 2005; 61: 378-384
- 5 Rex DK, Imperiale TF, Latinovich DR et al. Impact of bowel preparation on efficiency and cost of colonoscopy. Am J Gastroenterol 2002; 97: 1696-1700
- 6 Senore C, Ederle A, Fantin A et al. Acceptability and side-effects of colonoscopy and sigmoidoscopy in a screening setting. J Med Screen 2011; 18: 128-134
- 7 Atkins D, Best D, Briss PA et al. Grading quality of evidence and strength of recommendations. BMJ 2004; 328: 1490
- 8 Dumonceau J-M, Hassan C, Riphaus A et al. European Society of Gastrointestinal Endoscopy (ESGE) Guideline Development Policy. Endoscopy 2012; 44: 626-629
- 9 Wu K-L, Rayner CK, Chuah S-K et al. Impact of low-residue diet on bowel preparation for colonoscopy. Dis Colon Rectum 2011; 54: 107-112
- 10 Adams WJ, Meagher AP, Lubowski DZ et al. Bisacodyl reduces the volume of polyethylene glycol solution required for bowel preparation. Dis Colon Rectum 1994; 37: 229-233 discussion 233–224
- 11 Aoun E, Abdul-Baki H, Azar C et al. A randomized single-blind trial of split-dose PEG-electrolyte solution without dietary restriction compared with whole dose PEG-electrolyte solution with dietary restriction for colonoscopy preparation. Gastrointest Endosc 2005; 62: 213-218
- 12 Soweid AM, Kobeissy AA, Jamali FR et al. A randomized single-blind trial of standard diet versus fiber-free diet with polyethylene glycol electrolyte solution for colonoscopy preparation. Endoscopy 2010; 42: 633-638
- 13 Park DI, Park SH, Lee SK et al. Efficacy of prepackaged, low residual test meals with 4L polyethylene glycol versus a clear liquid diet with 4L polyethylene glycol bowel preparation: a randomized trial. J Gastroenterol Hepatol 2009; 24: 988-991
- 14 Lever EL, Walter MH, Condon SC et al. Addition of enemas to oral lavage preparation for colonoscopy is not necessary. Gastrointest Endosc 1992; 38: 369-372
- 15 Børkje B, Pedersen R, Lund GM et al. Effectiveness and acceptability of three bowel cleansing regimens. Scand J Gastroenterol 1991; 26: 162-166
- 16 Golub RW, Kerner BA, Wise WE et al. Colonoscopic bowel preparations – which one? A blinded, prospective, randomized trial. Dis Colon Rectum 1995; 38: 594-599
- 17 Tasci I, Altinli E, Sirin F. Bowel cleansing for diagnostic colonoscopy: which method is preferable? Istanbul experience. Tech Coloproctol 2003; 7: 18-21
- 18 Martínek J, Hess J, Delarive J et al. Cisapride does not improve precolonoscopy bowel preparation with either sodium phosphate or polyethylene glycol electrolyte lavage. Gastrointest Endosc 2001; 54: 180-185
- 19 Katsinelos P, Pilpilidis I, Paroutoglou G et al. The administration of cisapride as an adjuvant to PEG-electrolyte solution for colonic cleansing: a double-blind randomized study. Hepatogastroenterology 2005; 52: 441-443
- 20 Sanaka MR, Super DM, Mullen KD et al. Use of tegaserod along with polyethylene glycol electrolyte solution for colonoscopy bowel preparation: a prospective, randomized, double-blind, placebo-controlled study. Aliment Pharmacol Ther 2006; 23: 669-674
- 21 Mishima Y, Amano Y, Okita K et al. Efficacy of prokinetic agents in improving bowel preparation for colonoscopy. Digestion 2008; 77: 166-172
- 22 Tongprasert S, Sobhonslidsuk A, Rattanasiri S. Improving quality of colonoscopy by adding simethicone to sodium phosphate bowel preparation. World J Gastroenterol 2009; 15: 3032-3037
- 23 Shaver WA, Storms P, Peterson WL. Improvement of oral colonic lavage with supplemental simethicone. Dig Dis Sci 1988; 33: 185-188
- 24 Wu L, Cao Y, Liao C et al. Systematic review and meta-analysis of randomized controlled trials of Simethicone for gastrointestinal endoscopic visibility. Scand J Gastroenterol 2011; 46: 227-235
- 25 Altintaş E, Uçbilek E, Sezgin O et al. Alverine citrate plus simethicone reduces cecal intubation time in colonoscopy – a randomized study. Turk J Gastroenterol 2008; 19: 174-179
- 26 Lazzaroni M, Petrillo M, Desideri S et al. Efficacy and tolerability of polyethylene glycol-electrolyte lavage solution with and without simethicone in the preparation of patients with inflammatory bowel disease for colonoscopy. Aliment Pharmacol Ther 1993; 7: 655-659
- 27 McNally PR, Maydonovitch CL, Wong RK. The effect of simethicone on colonic visibility after night-prior colonic lavage. A double-blind randomized study. J Clin Gastroenterol 1989; 11: 650-652
- 28 McNally PR, Maydonovitch CL, Wong RK. The effectiveness of simethicone in improving visibility during colonoscopy: a double-blind randomized study. Gastrointest Endosc 1988; 34: 255-258
- 29 Sudduth RH, DeAngelis S, Sherman KE et al. The effectiveness of simethicone in improving visibility during colonoscopy when given with a sodium phosphate solution: a double-bind randomized study. Gastrointest Endosc 1995; 42: 413-415
- 30 Belsey J, Epstein O, Heresbach D. Systematic review: oral bowel preparation for colonoscopy. Aliment Pharmacol Ther 2007; 25: 373-384
- 31 Hsu CW, Imperiale TF. Meta-analysis and cost comparison of polyethylene glycol lavage versus sodium phosphate for colonoscopy preparation. Gastrointest Endosc 1998; 48: 276-282
- 32 Juluri R, Eckert G, Imperiale TF. Polyethylene glycol vs. sodium phosphate for bowel preparation: A treatment arm meta-analysis of randomized controlled trials. BMC Gastroenterology 2011; 11: 38
- 33 Juluri R, Eckert G, Imperiale TF. Meta-analysis: randomized controlled trials of 4-L polyethylene glycol and sodium phosphate solution as bowel preparation for colonoscopy. Aliment Pharmacol Ther 2010; 32: 171-181
- 34 Tan JJY, Tjandra JJ. Which is the optimal bowel preparation for colonoscopy – a meta-analysis. Colorectal Dis 2006; 8: 247-258
- 35 Belsey J, Crosta C, Epstein O et al. Meta-analysis: the relative efficacy of oral bowel preparations for colonoscopy 1985–2010. Aliment Pharmacol Ther 2012; 35: 222-237
- 36 Lawrance IC, Willert RP, Murray K. Bowel cleansing for colonoscopy: prospective randomized assessment of efficacy and of induced mucosal abnormality with three preparation agents. Endoscopy 2011; 43: 412-418 Epub 2011 May 4
- 37 Renaut AJ, Raniga S, Frizelle FA et al. A randomized controlled trial comparing the efficacy and acceptability of phospo-soda buffered saline (Fleet®) with sodium picosulphate/magnesium citrate (Picoprep®) in the preparation of patients for colonoscopy. Colorectal Dis 2008; 10: 503-505
- 38 Worthington J, Thyssen M, Chapman G et al. A randomised controlled trial of a new 2 litre polyethylene glycol solution versus sodium picosulphate + magnesium citrate solution for bowel cleansing prior to colonoscopy. Curr Med Res Opin 2008; 24: 481-488
- 39 Tjandra JJ, Chan M, Tagkalidis PP. Oral sodium phosphate (Fleet) is a superior colonoscopy preparation to Picopre (sodium picosulfate-based preparation). Dis Colon Rectum 2006; 49: 616-620
- 40 Schmidt L-M, Williams P, King D et al. Picoprep-3 is a superior colonoscopy preparation to Fleet: a randomized, controlled trial comparing the two bowel preparations. Dis Colon Rectum 2004; 47: 238-242
- 41 Berkelhammer C, Ekambaram A, Silva RG et al. Low-volume oral colonoscopy bowel preparation: sodium phosphate and magnesium citrate. Gastrointest Endosc 2002; 56: 89-94
- 42 Regev A, Fraser G, Delpre G et al. Comparison of two bowel preparations for colonoscopy: sodium picosulphate with magnesium citrate versus sulphate-free polyethylene glycol lavage solution. Am J Gastroenterol 1998; 93: 1478-1482
- 43 Hamilton D, Mulcahy D, Walsh D et al. Sodium picosulphate compared with polyethylene glycol solution for large bowel lavage: a prospective randomised trial. Br J Clin Pract 1996; 50: 73-75
- 44 Park SS, Sinn DH, Kim Y-H et al. Efficacy and tolerability of split-dose magnesium citrate: low-volume (2 liters) polyethylene glycol vs. single- or split-dose polyethylene glycol bowel preparation for morning colonoscopy. Am J Gastroenterol 2010; 105: 1319-1326
- 45 Sharma VK, Chockalingham SK, Ugheoke EA et al. Prospective, randomized, controlled comparison of the use of polyethylene glycol electrolyte lavage solution in four-liter versus two-liter volumes and pretreatment with either magnesium citrate or bisacodyl for colonoscopy preparation. Gastrointest Endosc 1998; 47: 167-171
- 46 Jansen SV, Goedhard JG, Winkens B et al. Preparation before colonoscopy: a randomized controlled trial comparing different regimes. Eur J Gastroenterol Hepatol 2011; 23: 897-902
- 47 Pontone S. Low-volume plus ascorbic acid vs high-volume plus simethicone bowel preparation before colonoscopy. World J Gastroenterol 2011; 17: 4689-4695
- 48 Corporaal S, Kleibeuker JH, Koornstra JJ. Low-volume PEG plus ascorbic acid versus high-volume PEG as bowel preparation for colonoscopy. Scand J Gastroenterol 2010; 45: 1380-1386
- 49 Marmo R, Rotondano G, Riccio G et al. Effective bowel cleansing before colonoscopy: a randomized study of split-dosage versus non-split dosage regimens of high-volume versus low-volume polyethylene glycol solutions. Gastrointest Endosc 2010; 72: 313-320
- 50 Ell C, Fischbach W, Bronisch H-J et al. Randomized trial of low-volume PEG solution versus standard PEG + electrolytes for bowel cleansing before colonoscopy. Am J Gastroenterol 2008; 103: 883-893
- 51 Singh H, Turner D, Xue L et al. Risk of developing colorectal cancer following a negative colonoscopy examination: evidence for a 10-year interval between colonoscopies. JAMA 2006; 295: 2366-2373
- 52 Baxter NN, Goldwasser MA, Paszat LF et al. Association of colonoscopy and death from colorectal cancer. Ann Intern Med 2009; 150: 1-8
- 53 Abut E, Guveli H, Yasar B et al. Administration of olive oil followed by a low volume of polyethylene glycol-electrolyte lavage solution improves patient satisfaction with right-side colonic cleansing over administration of the conventional volume of polyethylene glycol-electrolyte lavage solution for colonoscopy preparation. Gastrointest Endosc 2009; 70: 515-521
- 54 Haapamäki MM, Lindström M, Sandzén B. Low-volume bowel preparation is inferior to standard 4 1 polyethylene glycol. Surg Endosc 2011; 25: 897-901
- 55 Enestvedt BK, Fennerty MB, Eisen GM. Randomised clinical trial: MiraLAX vs. Golytely – a controlled study of efficacy and patient tolerability in bowel preparation for colonoscopy. Aliment Pharmacol Ther 2011; 33: 33-40
- 56 Hookey LC, Depew WT, Vanner SJ. Combined low volume polyethylene glycol solution plus stimulant laxatives versus standard volume polyethylene glycol solution: a prospective, randomized study of colon cleansing before colonoscopy. Can J Gastroenterol 2006; 20: 101-105
- 57 DiPalma JA, Mcgowan J, Cleveland MV. Clinical trial: an efficacy evaluation of reduced bisacodyl given as part of a polyethylene glycol electrolyte solution preparation prior to colonoscopy. Aliment Pharmacol Ther 2007; 26: 1113-1119
- 58 Kilgore TW, Abdinoor AA, Szary NM et al. Bowel preparation with split-dose polyethylene glycol before colonoscopy: a meta-analysis of randomized controlled trials. Gastrointest Endosc 2011; 73: 1240-1245
- 59 Parra-Blanco A, Nicolas-Perez D, Gimeno-Garcia A et al. The timing of bowel preparation before colonoscopy determines the quality of cleansing, and is a significant factor contributing to the detection of flat lesions: a randomized study. World J Gastroenterol 2006; 12: 6161-6166
- 60 Church JM. Effectiveness of polyethylene glycol antegrade gut lavage bowel preparation for colonoscopy – timing is the key!. Dis Colon Rectum 1998; 41: 1223-1225
- 61 Varughese S, Kumar AR, George A et al. Morning-only one-gallon polyethylene glycol improves bowel cleansing for afternoon colonoscopies: a randomized endoscopist-blinded prospective study. Am J Gastroenterol 2010; 105: 2368-2374
- 62 Matro R, Shnitser A, Spodik M et al. Efficacy of morning-only compared with split-dose polyethylene glycol electrolyte solution for afternoon colonoscopy: a randomized controlled single-blind study. Am J Gastroenterol 2010; 105: 1954-1961
- 63 Longcroft-Wheaton G, Bhandari P. Same-day bowel cleansing regimen is superior to a split-dose regimen over 2 days for afternoon colonoscopy: results from a large prospective series. J Clin Gastroenterol 2012; 46: 57-61
- 64 Eun CS, Han DS, Hyun YS et al. The timing of bowel preparation is more important than the timing of colonoscopy in determining the quality of bowel cleansing. Dig Dis Sci 2011; 56: 539-544
- 65 Siddiqui AA, Yang K, Spechler SJ et al. Duration of the interval between the completion of bowel preparation and the start of colonoscopy predicts bowel-preparation quality. Gastrointest Endosc 2009; 69: 700-706
- 66 Huffman M, Unger RZ, Thatikonda C et al. Split-dose bowel preparation for colonoscopy and residual gastric fluid volume: an observational study. Gastrointest Endosc 2010; 72: 516-522
- 67 Khan MA, Piotrowski Z, Brown MD. Patient acceptance, convenience, and efficacy of single-dose versus split-dose colonoscopy bowel preparation. J Clin Gastroenterol 2010; 44: 310-311
- 68 Unger RZ, Amstutz SP, Seo DH et al. Willingness to undergo split-dose bowel preparation for colonoscopy and compliance with split-dose instructions. Dig Dis Sci 2010; 55: 2030-2034
- 69 Park JS, Sohn CI, Hwang SJ et al. Quality and effect of single dose versus split dose of polyethylene glycol bowel preparation for early-morning colonoscopy. Endoscopy 2007; 39: 616-619
- 70 Committee on Standards and Practice Parameters, American Society of Anesthesiologists. Practice guidelines for preoperative fasting and the use of pharmacologic agents to reduce the risk of pulmonary aspiration: application to healthy patients undergoing elective procedures: An updated report by the American Society of Anesthesiologists Committee on Standards and Practice Parameters. Anesthesiology 2011; 114: 495-511
- 71 Vradelis S, Kalaitzakis E, Sharifi Y et al. Addition of senna improves quality of colonoscopy preparation with magnesium citrate. World J Gastroenterol 2009; 15: 1759-1763
- 72 Ziegenhagen DJ, Zehnter E, Tacke W et al. Addition of senna improves colonoscopy preparation with lavage: a prospective randomized trial. Gastrointest Endosc 1991; 37: 547-549
- 73 Ziegenhagen DJ, Zehnter E, Tacke W et al. Senna vs. bisacodyl in addition to Golytely lavage for colonoscopy preparation – a prospective randomized trial. Z Gastroenterol 1992; 30: 17-19
- 74 Amato A, Radaelli F, Paggi S et al. Half doses of PEG-ES and senna vs. high-dose senna for bowel cleansing before colonoscopy: a randomized, investigator-blinded trial. Am J Gastroenterol 2010; 105: 675-681
- 75 Radaelli F, Meucci G, Imperiali G et al. High-dose senna compared with conventional PEG-ES lavage as bowel preparation for elective colonoscopy: a prospective, randomized, investigator-blinded trial. Am J Gastroenterol 2005; 100: 2674-2680
- 76 Unal S, Doğan UB, Oztürk Z et al. A randomized prospective trial comparing 45 and 90-ml oral sodium phosphate with X-Prep in the preparation of patients for colonoscopy. Acta Gastroenterol Belg 1998; 61: 281-284
- 77 Kositchaiwat S, Suwanthanmma W, Suvikapakornkul R et al. Comparative study of two bowel preparation regimens for colonoscopy: senna tablets vs sodium phosphate solution. World J Gastroenterol 2006; 12: 5536-5539
- 78 Hangartner PJ, Münch R, Meier J et al. Comparison of three colon cleansing methods: evaluation of a randomized clinical trial with 300 ambulatory patients. Endoscopy 1989; 21: 272-275
- 79 Chen T-A, Wong H-Y, Lin C-K et al. High-dose bisacodyl plus water lavage compared with oral sodium phosphate as bowel preparation for outpatient colonoscopy. J Chin Med Assoc 2009; 72: 402-407
- 80 Rasmussen M, Bohlbro K, Qvist N. Oral sodium phosphate compared with water enemas combined with bisacodyl as bowel preparation for elective colonoscopy. Scand J Gastroenterol 2003; 38: 1090-1094
- 81 Wang H-S, Lin J-K. A randomized prospective trial of bowel preparation for colonoscopy with Fortrans compared with bisacodyl. J Chin Med Assoc 2003; 66: 364-369
- 82 Chacaltana Mendoza A, Rodríguez Ulloa C. [Comparative study between manitol 10% and polyethyleneglycol [corrected] in colonoscopic preparation in inpatients of FAP Central Hospital]. Rev Gastroenterol Peru 2008; 28: 125-132
- 83 Habr-Gama A, Bringel RW, Nahas SC et al. Bowel preparation for colonoscopy: comparison of mannitol and sodium phosphate. Results of a prospective randomized study. Rev Hosp Clin Fac Med Sao Paulo 1999; 54: 187-192
- 84 Rey JF, Beilenhoff U, Neumann CS et al. European Society of Gastrointestinal Endoscopy (ESGE) guideline: the use of electrosurgical units. Endoscopy 2010; 42: 764-772
- 85 Markowitz GS, Stokes MB, Radhakrishnan J et al. Acute phosphate nephropathy following oral sodium phosphate bowel purgative: an underrecognized cause of chronic renal failure. J Am Soc Nephrol 2005; 16: 3389-3396
- 86 Brunelli SM. Association between oral sodium phosphate bowel preparations and kidney injury: a systematic review and meta-analysis. Am J Kidney Dis 2009; 53: 448-456
- 87 Belsey J, Epstein O, Heresbach D. Systematic review: adverse event reports for oral sodium phosphate and polyethylene glycol. Aliment Pharmacol Ther 2009; 29: 15-28
- 88 Pálmadóttir VK, Gudmundsson H, Hardarson S et al. Incidence and outcome of acute phosphate nephropathy in Iceland. PLoS One 2010; 5: e13484
- 89 Hookey LC, Vanner S. Recognizing the clinical contraindications to the use of oral sodium phosphate for colon cleansing: a case study. Can J Gastroenterol 2004; 18: 455-458
- 90 Wexner SD, Beck DE, Baron TH et al. A consensus document on bowel preparation before colonoscopy: prepared by a task force from the American Society of Colon and Rectal Surgeons (ASCRS), the American Society for Gastrointestinal Endoscopy (ASGE), and the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES). Gastrointest Endosc 2006; 63: 894-909
- 91 Balaban DH. Guidelines for the safe and effective use of sodium phosphate solution for bowel cleansing prior to colonoscopy. Gastroenterol Nurs 2008; 31: 327-334 ; quiz 334–325
- 92 Rex DK, Vanner SJ. Colon cleansing before colonoscopy: does oral sodium phosphate solution still make sense?. Can J Gastroenterol 2009; 23: 210-214
- 93 Marshall JB, Pineda JJ, Barthel JS et al. Prospective, randomized trial comparing sodium phosphate solution with polyethylene glycol-electrolyte lavage for colonoscopy preparation. Gastrointest Endosc 1993; 39: 631-634
- 94 Zhang Q-L, Rothenbacher D. Prevalence of chronic kidney disease in population-based studies: systematic review. BMC Public Health 2008; 8: 117
- 95 Russmann S, Lamerato L, Marfatia A et al. Risk of impaired renal function after colonoscopy: a cohort study in patients receiving either oral sodium phosphate or polyethylene glycol. Am J Gastroenterol 2007; 102: 2655-2663
- 96 Markowitz GS, Perazella MA. Acute phosphate nephropathy. Kidney Int 2009; 76: 1027-1034
- 97 Law W-L, Choi H-K, Chu K-W et al. Bowel preparation for colonoscopy: a randomized controlled trial comparing polyethylene glycol solution, one dose and two doses of oral sodium phosphate solution. Asian J Surg 2004; 27: 120-124
- 98 Malik P, Balaban DH, Thompson WO et al. Randomized study comparing two regimens of oral sodium phosphates solution versus low-dose polyethylene glycol and bisacodyl. Dig Dis Sci 2009; 54: 833-841
- 99 Rex DK, Schwartz H, Goldstein M et al. Safety and colon-cleansing efficacy of a new residue-free formulation of sodium phosphate tablets. Am J Gastroenterol 2006; 101: 2594-2604
- 100 Wruble L, Demicco M, Medoff J et al. Residue-free sodium phosphate tablets (OsmoPrep) versus Visicol for colon cleansing: a randomized, investigator-blinded trial. Gastrointest Endosc 2007; 65: 660-670
- 101 Frommer D. Cleansing ability and tolerance of three bowel preparations for colonoscopy. Dis Colon Rectum 1997; 40: 100-104
- 102 Hassan C, Fuccio L, Bruno M et al. A predictive model identifies patients most likely to have inadequate bowel preparation for colonoscopy. Clin Gastroenterol Hepatol 2012; 10: 501-506
- 103 Chan WK, Saravanan A, Manikam J et al. Appointment waiting times and education level influence the quality of bowel preparation in adult patients undergoing colonoscopy. BMC Gastroenterol 2011; 11: 86
- 104 Tae JW, Lee JC, Hong SJ et al. Impact of patient education with cartoon visual aids on the quality of bowel preparation for colonoscopy. Gastrointest Endosc 2012; 76: 804-11
- 105 Spiegel BM, Talley J, Shekelle P et al. Development and validation of a novel patient educational booklet to enhance colonoscopy preparation. Am J Gastroenterol 2011; 106: 875-883
- 106 Borg BB, Gupta NK, Zuckerman GR et al. Impact of obesity on bowel preparation for colonoscopy. Clin Gastroenterol Hepatol 2009; 7: 670-675
- 107 Chan W-K, Saravanan A, Manikam J et al. Appointment waiting times and education level influence the quality of bowel preparation in adult patients undergoing colonoscopy. BMC Gastroenterol 2011; 11: 86
- 108 Chung YW, Han DS, Park KH et al. Patient factors predictive of inadequate bowel preparation using polyethylene glycol: a prospective study in Korea. J Clin Gastroenterol 2009; 43: 448-452
- 109 Lebwohl B, Wang TC, Neugut AI. Socioeconomic and other predictors of colonoscopy preparation quality. Dig Dis Sci 2010; 55: 2014-2020
- 110 Ness RM, Manam R, Hoen H et al. Predictors of inadequate bowel preparation for colonoscopy. Am J Gastroenterol 2001; 96: 1797-1802
- 111 Ben-Horin S, Bar-Meir S, Avidan B. The outcome of a second preparation for colonoscopy after preparation failure in the first procedure. Gastrointest Endosc 2009; 69: 626-630
- 112 Ibáñez M, Parra-Blanco A, Zaballa P et al. Usefulness of an intensive bowel cleansing strategy for repeat colonoscopy after preparation failure. Dis Colon Rectum 2011; 54: 1578-1584
- 113 Lieberman D, Nadel M, Smith RA et al. Standardized colonoscopy reporting and data system: report of the Quality Assurance Task Group of the National Colorectal Cancer Roundtable. Gastrointest Endosc 2007; 65: 757-766
- 114 de Jonge V, Sint Nicolaas J, Cahen DL et al. Quality evaluation of colonoscopy reporting and colonoscopy performance in daily clinical practice. Gastrointest Endosc 2012; 75: 98-106
- 115 Rigaux J, Juriens I, Devière J. A novel system for the improvement of colonic cleansing during colonoscopy. Endoscopy 2012; 44: 703-706
- 116 Cappell MS, Colon VJ, Sidhom OA. A study at 10 medical centers of the safety and efficacy of 48 flexible sigmoidoscopies and 8 colonoscopies during pregnancy with follow-up of fetal outcome and with comparison to control groups. Dig Dis Sci 1996; 41: 2353-2361
- 117 Cappell MS, Fox SR, Gorrepati N. Safety and efficacy of colonoscopy during pregnancy: an analysis of pregnancy outcome in 20 patients. J Reprod Med 2010; 55: 115-123
- 118 Briggs GG, Freeman RK, Yaffe SJ. Drugs in pregnancy and lactation: a reference guide to fetal and neonatal risk. 9th. edn. Philadelphia: Lippincott Williams & Wilkins; 2011
- 119 Nardulli G, Limongi F, Sue G et al. [Use of polyethylene glycol in the treatment of puerperal constipation]. GEN 1995; 49: 224-226
- 120 Vinod J, Bonheur J, Korelitz BI et al. Choice of laxatives and colonoscopic preparation in pregnant patients from the viewpoint of obstetricians and gastroenterologists. World J Gastroenterol 2007; 13: 6549-6552
- 121 Atkinson RJ, Save V, Hunter JO. Colonic ulceration after sodium phosphate bowel preparation. Am J Gastroenterol 2005; 100: 2603-2605
- 122 Rejchrt S, Bures J, Siroký M et al. A prospective, observational study of colonic mucosal abnormalities associated with orally administered sodium phosphate for colon cleansing before colonoscopy. Gastrointest Endosc 2004; 59: 651-654
- 123 Coskun A, Uzunkoy A, Duzgun SA et al. Experimental sodium phosphate and polyethylene glycol induce colonic tissue damage and oxidative stress. Br J Surg 2001; 88: 85-89
- 124 Erdogan B, Isiksoy S, Dundar E et al. The effects of sodium phosphate and polyethylene glycol-electrolyte bowel preparation solutions on 2,4,6-trinitrobenzenesulfonic acid-induced colitis in the rat. Exp Toxicol Pathol 2003; 55: 213-220
- 125 Colacchio TA, Forde KA, Patsos TJ et al. Impact of modern diagnostic methods on the management of active rectal bleeding. Ten year experience. Am J Surg 1982; 143: 607-610
- 126 Das A, Ben-Menachem T, Cooper GS et al. Prediction of outcome in acute lower-gastrointestinal haemorrhage based on an artificial neural network: internal and external validation of a predictive model. Lancet 2003; 362: 1261-1266
- 127 Green BT, Rockey DC, Portwood G et al. Urgent colonoscopy for evaluation and management of acute lower gastrointestinal hemorrhage: a randomized controlled trial. Am J Gastroenterol 2005; 100: 2395-2402
- 128 Jensen DM, Machicado GA, Jutabha R et al. Urgent colonoscopy for the diagnosis and treatment of severe diverticular hemorrhage. N Engl J Med 2000; 342: 78-82
- 129 Jensen DM, Machicado GA. Diagnosis and treatment of severe hematochezia. The role of urgent colonoscopy after purge. Gastroenterology 1988; 95: 1569-1574
- 130 Laine L, Shah A. Randomized trial of urgent vs. elective colonoscopy in patients hospitalized with lower GI bleeding. Am J Gastroenterol 2010; 105: 2636-2641 quiz 2642
- 131 Lanas A, García-Rodríguez LA, Polo-Tomás M et al. Time trends and impact of upper and lower gastrointestinal bleeding and perforation in clinical practice. Am J Gastroenterol 2009; 104: 1633-1641
- 132 Saito K, Inamori M, Sekino Y et al. Management of acute lower intestinal bleeding: what bowel preparation should be required for urgent colonoscopy?. Hepatocastroenterology 2009; 56: 1331-1334