Endoscopy 2012; 44(08): 746-753
DOI: 10.1055/s-0032-1310063
Original article
© Georg Thieme Verlag KG Stuttgart · New York

A prospective randomized study on the benefits of a new small-caliber colonoscope

Authors

  • K. Sato

    Division of Gastroenterology, Department of Internal Medicine, Toho University Ohashi Medical Center, Tokyo, Japan
  • S. Ito

    Division of Gastroenterology, Department of Internal Medicine, Toho University Ohashi Medical Center, Tokyo, Japan
  • F. Shigiyama

    Division of Gastroenterology, Department of Internal Medicine, Toho University Ohashi Medical Center, Tokyo, Japan
  • T. Kitagawa

    Division of Gastroenterology, Department of Internal Medicine, Toho University Ohashi Medical Center, Tokyo, Japan
  • K. Hirahata

    Division of Gastroenterology, Department of Internal Medicine, Toho University Ohashi Medical Center, Tokyo, Japan
  • K. Tominaga

    Division of Gastroenterology, Department of Internal Medicine, Toho University Ohashi Medical Center, Tokyo, Japan
  • I. Maetani

    Division of Gastroenterology, Department of Internal Medicine, Toho University Ohashi Medical Center, Tokyo, Japan
Further Information

Publication History

submitted 30 December 2011

accepted after revision 18 June 2012

Publication Date:
25 July 2012 (online)

Preview

Background and study aims: We compared the performance efficiency of a newly developed small-caliber colonoscope (PCF-PQ260 L) with passive bending, high force transmission, and an outer diameter of 9.2 mm with that of a standard colonoscope, in female and male patients, particularly with regard to passage through acute angulations or into the proximal colon.

Patients and methods: A total of 330 patients were randomly allocated to undergo small-caliber (n = 164) or standard (n = 166) colonoscopy. The patients were assessed for pain using a visual analogue scale (0 = none, 100 = extremely painful), and for cecal intubation, withdrawal time, difficulty of colonoscopy, dosage and level of sedation used, and any complications.

Results: Median maximum pain and overall pain during colonoscopy were significantly lower in the small-caliber group than in the standard group in women (25 vs. 45, P < 0.001 and 15 vs. 26, P = 0.001, respectively), whereas no significant differences were seen in men (8 vs. 10, P = 0.103 and 16 vs. 20, P = 0.166, respectively). Furthermore, no significant differences were seen between groups in cecal intubation rate or time to cecum in all patients or by sex.

Conclusions: Use of the small-caliber colonoscope reduced pain in female patients, but offered no advantage over standard colonoscopy in male patients. The performance of the small-caliber colonoscope was equivalent to that of the standard colonoscope in terms of cecal intubation rate and time to cecum, regardless of the sex of the patient.