Klin Monbl Augenheilkd 2009; 226(8): 629-633
DOI: 10.1055/s-0028-1109382
Experimentelle Studie

© Georg Thieme Verlag KG Stuttgart · New York

Isoliereigenschaft von Transportbehältern für organkultivierte Spenderhornhäute bei wechselnden Umgebungstemperaturen

Insulation Characteristics of Transport Containers for Organ Cultured Donor Corneas under Different Ambient TemperaturesJ. Schroeter1 , C. Meltendorf2
  • 1Augenklinik Campus Virchow-Klinikum, Charité-Universitätsmedizin Berlin
  • 2Universitätsklinik und Poliklinik für Augenheilkunde, Martin-Luther-Universität, Halle (Saale)
Further Information

Publication History

Eingegangen: 19.1.2009

Angenommen: 17.3.2009

Publication Date:
27 April 2009 (online)

Zusammenfassung

Hintergrund: Ziel dieser Studie war es zu untersuchen, ob Transportbehälter für organkultivierte Spenderhornhäute bei unterschiedlichen Außentemperaturen die Temperatur in ihrem Innenraum für 24 h zwischen +10 und +40 °C halten können, ein Temperaturbereich, der als sicher für organkultivierte Hornhäute angesehen wird. Material und Methoden: 3 Transportbehälter wurden getestet: 1. Styroporkiste (Graft-tec, AL.CHI.MI.A., Padova, Italien), Wandstärke 2,5 cm. 2. Thermobehälter 0,5 l (Primus, Solna, Schweden), ein doppelwandiger Becher aus Edelstahl. 3. TempShell-22 °C (delta T Gesellschaft für Medizintechnik mbH, Gießen, Deutschland), ein Behälter mit Elementen aus Kunststoff, die mit Phasenübergangsmaterial gefüllt waren. Die Transportbehälter wurden Umgebungstemperaturen von –10, 0, +10 und +50 °C für 24 h ausgesetzt. Eine kontinuierliche Aufzeichnung der Umgebungstemperatur sowie der Temperatur im Transportbehälter erfolgte durch elektronische Thermometer (Mini Intelligent Temperature Logger, Escort). Ergebnisse: Die Temperatur in der Styroporkiste glich sich nach 80 – 230 min allen getesteten Umgebungstemperaturen an. Beim Thermobehälter erreichte die Innentemperatur die jeweilige Umgebungstemperatur nach etwa 5 h. Im Gegensatz dazu fand sich bei –10 °C Umgebungstemperatur im Innenraum der TempShell-22 °C nach 6 h eine Temperatur von 21 °C, nach 12 h von 19 °C und nach 24 h von 12 °C. Bei einer Umgebungstemperatur von 0 bzw. +10 °C betrug die Temperatur in der TempShell 19,2 bzw. 17,8 °C nach 24 h. Eine Umgebungstemperatur von +50 °C führte zu einer Temperaturerhöhung in der TempShell auf 30,5 °C nach 6 h, auf 38,3 °C nach 12 h und auf 47,0 °C nach 24 h. Schlussfolgerungen: Styroporkisten mit einer Wandstärke von 2,5 cm und der getestete Thermobehälter sind nicht geeignet, die Einhaltung sicherer Temperaturen für Spenderhornhäute zu gewährleisten. Hingegen ist die TempShell-22 °C gut geeignet, die Spenderhornhäute vor schädigenden Temperaturschwankungen zu schützen. Bei Umgebungstemperaturen zwischen –10 und +10 °C gewährleisten sie sichere Temperaturen für mindestens 24 h und bei Umgebungstemperaturen von +50 °C für mindestens 10 h.

Abstract

Background: The aim of this study was to evaluate the ability of different transport containers to maintain an inside temperature between +10 and +40 °C, which is supposed to be safe for organ cultured donor corneas in dextran containing culture media, for a period of 24 hours at ambient temperatures of –10, 0, +10 and +50 °C. Materials and Methods: 3 containers were tested: 1. Styrofoam box with 2.5 cm thick walls (Graft-tec, AL.CHI.MI.A., Padova, Italy). 2. Thermos jug 0.5 litre (Primus, Solna, Sweden), a double walled metal jug. 3. ThempShell-22° (VWR International, Darmstadt, Germany), a box of gel filled plastic elements. The containers were exposed to –10, 0, +10 and +50 °C for 24 hours each. A continuous temperature recording of the ambient and internal environments was performed using electronic thermometers (Mini Intelligent Logger, Escort). Results: The inside temperature of the styrofoam box reached the outside temperature level after 80 – 230 min for all tested settings. The Thermos jug reached the outside temperature approximately after 5 hours. In contrast, the inside temperature of the TempShell-22 °CC was at –10 °C outside temperature 21 °C after 6 hours, 19 °C after 12 hours and 12 °C after 24 hours. At an ambient temperature of 0 and +10 °C the inside temperature of the TempShell-22 °C was 19.2 and 17.8 °C respectively after 24 hours. An ambient temperature of + 50 °C led to an inside temperature of the TempShell-22 °C of 30.5 °C after 6, 38.3 °C after 12 hours and 47.0 °C after 24 hours. Conclusions: A standard Styrofoam box with 2.5 cm thick walls and the tested thermos jug are not suitable to assure a safe temperature range. The TempShell-22 °C assures a safe temperature range for low ambient temperatures (–10 to +10 °C) for at least 24 hours and for an ambient temperature of +50 °C for at least 10 hours.

Literatur

  • 1 Lundh B L, Källmark B. Endothelial cell density after penetrating keratoplasty using long-time banked donor material after long distance transportation (Denmark-Sweden).  Acta Ophthalmol (Copenh). 1986;  64 (5) 492-498
  • 2 Net M, Trias E, Navarro A. et al . Cold chain monitoring during cold transportation of human corneas for transplantation.  Transplant Proc. 2003;  35 (5) 2036-2038
  • 3 Pels L. Organ culture: the method of choice for preservation of human donor corneas.  Br J Ophthalmol. 1997;  81 523-525
  • 4 Rosenbaum K, Reinhard T, Sundmacher R. Einflussfaktoren auf das Hornhautendothel in Organkultur während des Transports.  Ophthalmologe. 2004;  101 1209-1213
  • 5 Schroeter J, Meltendorf C, Ohrloff C. et al . Influence of temporary hypothermia on corneal endothelial cell density during organ culture preservation.  Graefe’s Arch Clin Exp Ophthalmol. 2008;  246 (3) 369-372
  • 6 Schroeter J, Maier P, Bednarz J. et al . Procedural guidelines: Good tissue practice for cornea banks.  Ophthalmologe. 2009;  in press DOI: epub ahead of print
  • 7 Shimazaki J, Shinozaki N, Shimmura S. et al . Efficacy and safety of international donor sharing: a single-center, case-controlled study on corneal transplantation.  Transplantation. 2004;  78 (2) 216-220
  • 8 Varssano D, Russ V, Linhart Y. et al . Air Transportation of Corneal Tissue, Experience with Local Compared to Transatlantic Donor Corneas.  Cornea. 2005;  24 674-677

Dr. Jan Schroeter

Augenklinik Campus Virchow-Klinikum, Charité-Universitätsmedizin Berlin

Augustenburger Platz 1

13353 Berlin

Phone: + + 49/30/4 50 55 40 99

Fax: + + 49/30/4 50 55 49 89

Email: dr@jan-schroeter.de

    >