J Wrist Surg
DOI: 10.1055/a-2622-5290
Scientific Article

Anatomical Fit of the Volar Locking Plate for Distal Radius and Influence of the Plate Size

1   Department of Orthopedic Surgery, Iwate Medical University, Iwate Ika Daigaku, Japan
,
Kotaro Sato
1   Department of Orthopedic Surgery, Iwate Medical University, Iwate Ika Daigaku, Japan
,
Kenya Murakami
1   Department of Orthopedic Surgery, Iwate Medical University, Iwate Ika Daigaku, Japan
,
Masanori Matsuura
1   Department of Orthopedic Surgery, Iwate Medical University, Iwate Ika Daigaku, Japan
,
Tomoyuki Saino
1   Department of Orthopedic Surgery, Iwate Medical University, Iwate Ika Daigaku, Japan
,
Minoru Doita
1   Department of Orthopedic Surgery, Iwate Medical University, Iwate Ika Daigaku, Japan
› Author Affiliations

Abstract

Purpose

The volar locking plates (VLPs) for distal radius fractures are currently available in different shapes and size options. Therefore, we investigated whether the anatomical fit and plate size of VLPs affect their proper placement.

Materials and Methods

Two sizes of Acu-Loc2 Proximal Plates (AcuLoc), three sizes of Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4 (VALCP), and 16 formalin-fixed cadaver specimens were studied. Computed tomography scans were performed on both the plates and forearms. The plate was fixed to a radius, and radiographs were obtained using fluoroscopy. X-rays were superimposed, and a three-dimensional image of the plate and bone was created. The distance from the plate to the bone (PBD) was measured, and the contact area between the bone and plate was analyzed. We measured the distance between the distal end of the plate and the watershed line, defining it as watershed overlap.

Results

The PBD in the radial column was significantly smaller than that in the ulnar column in the narrow and standard VALCP, as well as in the narrow AcuLoc. For the other plates, it tended to be smaller in the radial column than in the ulnar column. The contact area on the plate was small, and the average value of the watershed overlap was negative for both plates. However, no significant differences in each measurement item were observed among the plate sizes.

Conclusion

Although the small plate size affected the fitting to the distal radius, the variance was minimal; therefore, each plate size may be selected depending on the circumstances of the fracture.

Level of Evidence

Diagnostic Level III.

Patients' Consent

Patient consent has been obtained from all the patients.




Publication History

Received: 12 October 2024

Accepted: 26 May 2025

Article published online:
24 June 2025

© 2025. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Nellans KW, Kowalski E, Chung KC. The epidemiology of distal radius fractures. Hand Clin 2012; 28 (02) 113-125
  • 2 Jose A, Suranigi SM, Deniese PN, Babu AT, Rengasamy K, Najimudeen S. Unstable distal radius fractures treated by volar locking anatomical plates. J Clin Diagn Res 2017; 11 (01) RC04-RC08
  • 3 Chung KC, Watt AJ, Kotsis SV, Margaliot Z, Haase SC, Kim HM. Treatment of unstable distal radial fractures with the volar locking plating system. J Bone Joint Surg Am 2006; 88 (12) 2687-2694
  • 4 Orbay JL, Touhami A. Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res 2006; 445 (445) 58-67
  • 5 Imatani J, Akita K, Yamaguchi K, Shimizu H, Kondou H, Ozaki T. An anatomical study of the watershed line on the volar, distal aspect of the radius: implications for plate placement and avoidance of tendon ruptures. J Hand Surg Am 2012; 37 (08) 1550-1554
  • 6 Casaletto JA, Machin D, Leung R, Brown DJ. Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur Vol 2009; 34 (04) 471-474
  • 7 Kitay A, Swanstrom M, Schreiber JJ. et al. Volar plate position and flexor tendon rupture following distal radius fracture fixation. J Hand Surg Am 2013; 38 (06) 1091-1096
  • 8 Soong M, Earp BE, Bishop G, Leung A, Blazar P. Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am 2011; 93 (04) 328-335
  • 9 Yoneda H, Iwatsuki K, Hara T, Kurimoto S, Yamamoto M, Hirata H. Interindividual anatomical variations affect the plate-to-bone fit during osteosynthesis of distal radius fractures. J Orthop Res 2016; 34 (06) 953-960
  • 10 Buzzell JE, Weikert DR, Watson JT, Lee DH. Precontoured fixed-angle volar distal radius plates: a comparison of anatomic fit. J Hand Surg Am 2008; 33 (07) 1144-1152
  • 11 McIver ND, Salas C, Menon N, Heifner J, Mercer D. Appropriately matched fixed-angle locking plates improve stability in volar distal radius fixation. J Hand Surg Glob Online 2022; 4 (03) 135-140
  • 12 Evans S, Ramasamy A, Deshmukh SC. Distal volar radial plates: how anatomical are they?. Orthop Traumatol Surg Res 2014; 100 (03) 293-295
  • 13 Kwak DS, Lee JY, Im JH, Song HJ, Park D. Do volar locking plates fit the volar cortex of the distal radius?. J Hand Surg Eur Vol 2017; 42 (03) 266-270
  • 14 Beck JD, Harness NG, Spencer HT. Volar plate fixation failure for volar shearing distal radius fractures with small lunate facet fragments. J Hand Surg Am 2014; 39 (04) 670-678
  • 15 Gandhi RA, Hesketh PJ, Bannister ER, Sebro R, Mehta S. Age-related variations in volar cortical angle of the distal radius. Hand (N Y) 2020; 15 (04) 573-577
  • 16 Aaron JE, Makins NB, Sagreiya K. The microanatomy of trabecular bone loss in normal aging men and women. Clin Orthop Relat Res 1987; (215) 260-271
  • 17 Tommasini SM, Nasser P, Jepsen KJ. Sexual dimorphism affects tibia size and shape but not tissue-level mechanical properties. Bone 2007; 40 (02) 498-505
  • 18 Tommasini SM, Nasser P, Schaffler MB, Jepsen KJ. Relationship between bone morphology and bone quality in male tibias: implications for stress fracture risk. J Bone Miner Res 2005; 20 (08) 1372-1380
  • 19 O'Brien FJ, Brennan O, Kennedy OD, Lee TC. Microcracks in cortical bone: how do they affect bone biology?. Curr Osteoporos Rep 2005; 3 (02) 39-45
  • 20 Perrin M, Badre A, Suh N, Lalone EA. Analysis of three-dimensional anatomical variance and fit of the distal radius to current volar locking plate designs. J Hand Surg Glob Online 2020; 2 (05) 277-285
  • 21 Schlickum L, Quadlbauer S, Pezzei C, Stöphasius E, Hausner T, Leixnering M. Three-dimensional kinematics of the flexor pollicis longus tendon in relation to the position of the FPL plate and distal radius width. Arch Orthop Trauma Surg 2019; 139 (02) 269-279
  • 22 Kaiser P, Gruber H, Loth F, Schmidle G, Arora R, Gabl M. Positioning of a volar locking plate with a central flexor pollicis longus tendon notch in distal radius fractures. J Wrist Surg 2019; 8 (06) 482-488
  • 23 Limthongthang R, Bachoura A, Jacoby SM, Osterman AL. Distal radius volar locking plate design and associated vulnerability of the flexor pollicis longus. J Hand Surg Am 2014; 39 (05) 852-860
  • 24 Lill M, Schauer T, Schultes P, Wierer G, Deml C, Windhofer C. Avoiding screw overlength using dorsal horizon view in palmar plate osteosynthesis of distal radius fractures: a prospective randomized trial. Arch Orthop Trauma Surg 2024; 144 (01) 197-204
  • 25 Quadlbauer S, Pezzei C, Jurkowitsch J. et al. Functional and radiological outcome of distal radius fractures stabilized by volar-locking plate with a minimum follow-up of 1 year. Arch Orthop Trauma Surg 2020; 140 (06) 843-852
  • 26 Rosenauer R, Pezzei C, Quadlbauer S. et al. Complications after operatively treated distal radius fractures. Arch Orthop Trauma Surg 2020; 140 (05) 665-673
  • 27 Leixnering M, Rosenauer R, Pezzei C. et al. Indications, surgical approach, reduction, and stabilization techniques of distal radius fractures. Arch Orthop Trauma Surg 2020; 140 (05) 611-621
  • 28 Kim JK, Shin YH, Kim M. Ultrasonographic evaluation of contact configuration between flexor pollicis longus tendon and the volar prominence of volar plate in patients with distal radius fracture. Arch Orthop Trauma Surg 2023; 143 (02) 1103-1108
  • 29 Kwon BC, Lee JK, Lee SY, Hwang JY, Seo JH. Morphometric variations in the volar aspect of the distal radius. Clin Orthop Surg 2018; 10 (04) 462-467