A novel salvage method to recapture the maldeployed distal flange of a lumen-apposing metal stent

Department of Gastroenterology, Royal Stoke University Hospital, University Hospitals of North Midlands NHS Trust, Stoke-on-Trent, UK
,
Department of Gastroenterology, Royal Stoke University Hospital, University Hospitals of North Midlands NHS Trust, Stoke-on-Trent, UK
,
Chia Chuin Yau
Department of Gastroenterology, Royal Stoke University Hospital, University Hospitals of North Midlands NHS Trust, Stoke-on-Trent, UK
,
Wai Liam Lam
Department of Gastroenterology, Royal Stoke University Hospital, University Hospitals of North Midlands NHS Trust, Stoke-on-Trent, UK
,
Damien Durkin
Department of Gastroenterology, Royal Stoke University Hospital, University Hospitals of North Midlands NHS Trust, Stoke-on-Trent, UK
,
Srisha Hebbar
Department of Gastroenterology, Royal Stoke University Hospital, University Hospitals of North Midlands NHS Trust, Stoke-on-Trent, UK
› Author Affiliations
 

Endoscopic ultrasonography-guided choledochoduodenostomy (EUS-CDS) using an electrocautery-enhanced lumen-apposing metal stent (LAMS) is an effective tool in the endoscopic management of biliary obstruction [1]. Complications can occur during delivery of the LAMS, and these include maldeployment [2]. Several salvage methods have been described, such as stent-in stent, position adjustment post-full deployment [3], and natural orifice transluminal endoscopic surgery (NOTES) [4]. We describe a novel salvage method to recapture a partially deployed LAMS ([Video 1]).

Video 1 Endoscopic ultrasonographic views of the novel salvage method being used to recapture the maldeployed distal flange of a lumen-apposing metal stent and detailed view of the plastic safety latch being cut, which allows the grey hub to be pushed down, recapturing the distal flange and allowing the stent to be redeployed.


Quality:

A 65-year-old woman with an inoperable pancreatic head cancer was referred for biliary drainage. On EUS, the common bile duct (CBD) was found to be dilated at 20 mm. A 6-mm (lumen diameter) by 8-mm (saddle length) electrocautery-enhanced LAMS (Axios; Boston Scientific) was used to perform EUS-CDS in order to drain the obstructed bile duct. A freehand puncture of the CBD was performed and a guidewire was inserted as a safety measure. The distal flange was then fully deployed. Ultrasonography confirmed maldeployment outside of the CBD, with the stent being located in between the duodenal wall and the CBD.

The stent deployment mechanism contains a plastic safety latch that prevents accidental retraction of the sheath. This latch was cut using a wire cutter ([Fig. 1]). Without the latch, it was possible to push down the grey hub and recapture the distal flange. Once the distal flange had been recaptured, the stent delivery system was then advanced further into the bile duct and the recaptured stent was redeployed as usual. Finally, the correct placement of the stent was confirmed on endoscopic view, showing a good flow of bile out through the stent.

Zoom Image
Fig. 1 Photograph showing the plastic safety latch of the stent deployment mechanism being cut.

In summary, EUS–CDS with an electrocautery-enhanced LAMS is an effective tool to achieve biliary drainage; however, the procedure can be complicated by maldeployment. With our novel savage method, it was possible to recapture the stent and successfully redeploy it.

Endoscopy_UCTN_Code_CPL_1AL_2AD

Endoscopy E-Videos
https://eref.thieme.de/e-videos

Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online. Processing charges apply (currently EUR 375), discounts and wavers acc. to HINARI are available.

This section has its own submission website at https://mc.manuscriptcentral.com/e-videos


#

Competing interests

The authors declare that they have no conflict of interest.

Acknowledgment

Note: This salvage method is not endorsed by the manufacturer.

  • References

  • 1 Kuraoka N, Hara K, Okuno N. et al. Outcomes of EUS-guided choledochoduodenostomy as primary drainage for distal biliary obstruction with covered self-expandable metallic stents. Endosc Int Open 2020; 8: E861-E868
  • 2 Iqbal U, Khara HS, Hu Y. et al. EUS-guided gastroenterostomy for the management of gastric outlet obstruction: A systematic review and meta-analysis. Endosc Ultrasound 2020; 9: 16-23
  • 3 Hsueh W, Shah-Khan SM, Stemple M. et al. Salvage of a misdeployed 20-mm lumen-apposing metal stent by use of a through-the-scope esophageal stent. VideoGIE 2019; 4: 200-202
  • 4 Tyberg A, Saumoy M, Kahaleh M. Using NOTES to salvage a misdeployed lumen-apposing metal stent during an endoscopic ultrasound-guided gastroenterostomy. Endoscopy 2017; 49: 1007-1008

Corresponding author

Roderick Prawiradiradja, MB, BS
Department of Gastroenterology
Royal Stoke University Hospital
University Hospitals of North Midlands NHS Trust
Newcastle Road
Stoke-on-Trent
ST4 6QG
United Kingdom   

Publication History

Article published online:
16 February 2023

© 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

  • References

  • 1 Kuraoka N, Hara K, Okuno N. et al. Outcomes of EUS-guided choledochoduodenostomy as primary drainage for distal biliary obstruction with covered self-expandable metallic stents. Endosc Int Open 2020; 8: E861-E868
  • 2 Iqbal U, Khara HS, Hu Y. et al. EUS-guided gastroenterostomy for the management of gastric outlet obstruction: A systematic review and meta-analysis. Endosc Ultrasound 2020; 9: 16-23
  • 3 Hsueh W, Shah-Khan SM, Stemple M. et al. Salvage of a misdeployed 20-mm lumen-apposing metal stent by use of a through-the-scope esophageal stent. VideoGIE 2019; 4: 200-202
  • 4 Tyberg A, Saumoy M, Kahaleh M. Using NOTES to salvage a misdeployed lumen-apposing metal stent during an endoscopic ultrasound-guided gastroenterostomy. Endoscopy 2017; 49: 1007-1008

Zoom Image
Fig. 1 Photograph showing the plastic safety latch of the stent deployment mechanism being cut.