RSS-Feed abonnieren

DOI: 10.1055/a-1944-9175
Closure of full-thickness perforations in porcine stomach using 20-mm reopenable clips
It is difficult to close perforations that are large and full thickness in the gastrointestinal tract using conventional clips. Closure methods using special devices, including the over-the-scope (OTS) clip (Ovesco, Tübingen, Germany), have therefore been devised [1] [2] [3]. However, the OTS clip cannot be regripped and cannot be used unless the endoscope is pulled out for the clip to be attached [4]. Therefore, a device that can reliably close a perforation under endoscopic visibility is desired. We introduce a reopenable clip, which has a large width of 20 mm, and demonstrate its ability to close large gastric perforations in a porcine model.
The reopenable clip (LOCKADO hemostasis clip; 20 mm; Micro-Tech (Nanjing) Co., Ltd., Nanjing, China) has large teeth with an opening width of 20 mm ([Fig. 1]). It is possible to regrip and reposition the reopenable clip after it is opened. The clip has small teeth on both sides that are distinct from the tips of the teeth to prevent the gripped tissue from slipping.


A full-thickness perforation of approximately 15 mm was made in a porcine stomach ([Fig. 2]; [Video 1]). The perforation was then gradually closed using 20-mm reopenable clips placed from one end of the perforation to the other. Three 20-mm reopenable clips were used to achieve complete closure. Because of the greater width of the clips, the muscles and mucosa were inverted toward the stomach lumen, and no air leakage was observed outside the stomach. Next, a full-thickness perforation of 25 mm was created. Similarly, the perforation was closed from one end to the other. The clips are repositionable, so they can be grasped and changed to the appropriate position as required. For this larger perforation, an additional 11-mm reopenable clip was added; as a result, the full-layer perforation was completely closed without any air leak.


Video 1 Closure of two large full-thickness perforations of the stomach (15 mm and 25 mm) in a porcine model using 20-mm reopenable clips.
Qualität:
The 20-mm reopenable clip has the potential to close large full-thickness perforations.
Endoscopy_UCTN_Code_TTT_1AQ_2AG
Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online. Processing charges apply (currently EUR 375), discounts and wavers acc. to HINARI are available.
This section has its own submission website at https://mc.manuscriptcentral.com/e-videos
#
Competing interests
The authors declare that they have no conflict of interest.
-
References
- 1 von Renteln D, Schmidt A, Vassiliou MC. et al. Natural orifice transluminal endoscopic surgery gastrotomy closure with an over-the-endoscope clip: a randomized, controlled porcine study (with videos). Gastrointest Endosc 2009; 70: 732-739
- 2 Krutzenbichlet I, Dollhopf M, Diepolder H. et al. Technical success, resection status, and procedural complication rate of colonoscopic full-wall resection: a pooled analysis from 7 hospitals of different care levels. Surg Endosc 2021; 35: 3339-3353
- 3 Manta R, Mangiafico S, Zullo A. et al. First-line endoscopic treatment with over-the-scope clips in patients with either upper or lower gastrointestinal bleeding: a multicenter study. Endosc Int Open 2018; 6: E1317-E1321
- 4 Kobara H, Mori H, Nishiyama N. et al. Over-the-scope clip system: A review of 1517 cases over 9 years. J Gastroenterol Hepatol 2019; 34: 22-30
Corresponding author
Publikationsverlauf
Artikel online veröffentlicht:
10. Oktober 2022
© 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References
- 1 von Renteln D, Schmidt A, Vassiliou MC. et al. Natural orifice transluminal endoscopic surgery gastrotomy closure with an over-the-endoscope clip: a randomized, controlled porcine study (with videos). Gastrointest Endosc 2009; 70: 732-739
- 2 Krutzenbichlet I, Dollhopf M, Diepolder H. et al. Technical success, resection status, and procedural complication rate of colonoscopic full-wall resection: a pooled analysis from 7 hospitals of different care levels. Surg Endosc 2021; 35: 3339-3353
- 3 Manta R, Mangiafico S, Zullo A. et al. First-line endoscopic treatment with over-the-scope clips in patients with either upper or lower gastrointestinal bleeding: a multicenter study. Endosc Int Open 2018; 6: E1317-E1321
- 4 Kobara H, Mori H, Nishiyama N. et al. Over-the-scope clip system: A review of 1517 cases over 9 years. J Gastroenterol Hepatol 2019; 34: 22-30