Horm Metab Res 2022; 54(05): 300-307
DOI: 10.1055/a-1768-0709
Original Article: Endocrine Care

An LC-MS/MS Methodological Framework for Steroid Hormone Measurement from Human Serum

Karina Gasbarrino
1   Department of Medicine, McGill University, Montreal, Quebec, Canada
,
Edward Daly
2   Clinical Proteomics and Mass Spectrometry, McGill University, Montreal, Canada
,
Stella S. Daskalopoulou
1   Department of Medicine, McGill University, Montreal, Quebec, Canada
› Author Affiliations

Funding Information This work was supported by the Canadian Institutes of Health Research [CIHR, PJT-148966/FRN 145589] and the Heart & Stroke Foundation of Canada [G-17-0018755]. SS Daskalopoulou is a Senior Chercheur-Boursier Clinicien supported by the Fonds de recherche du Québec – Santé. Karina Gasbarrino is recipient of the Libin Cardiovascular Institute of Alberta Research Prize.
Preview

Abstract

Estrogens and androgens are important regulators of sexual development and physiological processes in men and women, acting on numerous organs throughout the body. Moreover, they can contribute to a variety of pathologies, including osteoporosis, cancer, and cardiovascular and neurologic diseases. Analysis of estrogens and androgens in biological samples has been commonly performed using immunoassays for many years. However, these assays are suboptimal, as there is cross-reactivity with similar analytes, and they have moderate specificity and sensitivity. Thus, there is a clinical need to develop highly sensitive and specific methods for the accurate measurement of estrogen and androgen concentrations. Herein, we describe the development of three liquid chromatography coupled tandem mass spectrometry-based methods that incorporate the use of a Triple Quadrupole Mass Spectrometer for quantitative measurement of endogenous concentrations of various steroid hormones in human serum samples: (1) the simultaneous measurement of testosterone, androstenedione, and cortisol, (2) dehydroepiandrosterone (DHEA), and (3) 17β-estradiol (E2). The use of derivatizing reagents, Girard’s reagent P and dansyl chloride, allowed for significant gains in sensitivity in the analysis of DHEA and E2, respectively, relative to the underivatized analyte. These procedures proved efficient and adequately sensitive for steroid hormone analysis in extracted patient sera samples from older men and postmenopausal women, providing reliable data down to low nanogram/ml and sub-nanogram/ml levels. Moreover, utilizing the combination of highly specific mass transitions associated with these analytes and their respective internal deuterated standards provided a high degree of specificity to the identity of these hormones.

Supplementary Material



Publication History

Received: 13 January 2022

Accepted after revision: 26 January 2022

Article published online:
29 March 2022

© 2022. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany