Endoscopy 2021; 53(02): E55-E57
DOI: 10.1055/a-1173-8540
E-Videos

The challenge of fistula closure in Crohn's disease: an endoscopic technique for closure of a fistula

Satohiro Matsumoto
Department of Gastroenterology, Saitama Medical Center, Jichi Medical University, Saitama, Japan
,
Hirosato Mashima
Department of Gastroenterology, Saitama Medical Center, Jichi Medical University, Saitama, Japan
› Author Affiliations
 

Crohn's disease is associated with many intestinal complications, such as stenosis and fistula, and many cases require intestinal resection during the course of the disease. Although anti-tumor necrosis factor α (TNFα) agents are effective in inducing remission of active Crohnʼs disease, they are ineffective for certain intestinal complications, such as fistulas [1]. We attempted endoscopic closure for a patient in whom anti-TNFα agents were not effective in treating the fistula.

The patient was a 52-year-old man with ileal- and colonic-type Crohnʼs disease who was receiving maintenance treatment with infliximab. He had been experiencing sudden bowel movements and watery stool for several years owing to a cecal–sigmoid fistula that had not closed with infliximab treatment. Colonoscopy revealed a cecal–sigmoid fistula that allowed a 10.8-mm endoscope to be passed through it ([Fig. 1]).

Zoom
Fig. 1 Colonoscopy revealed a cecal – sigmoid fistula as observed from: a the sigmoid colon; b the cecum. c Elective colonography revealed a cecal–sigmoid fistula of 10 mm in diameter.

We obtained informed consent from the patient and attempted endoscopic closure of this fistula ([Fig. 2]; [Video 1]). An endoscopic purse-string suture with a nylon loop and clips was placed using a two-channel scope. Although complete closure was not achieved, the fistula shrank and the patient’s subjective symptoms markedly improved ([Fig. 3]).

Zoom
Fig. 2 Endoscopic views showing the procedure used to close the fistula. a The operator placed a nylon loop on the margin of the fistula using a two-channel endoscope. b The nylon loop was clipped to the margin of the fistula from the distal to the proximal end on both sides. c The assistant tightened the handle of the nylon loop to narrow it and close the fistula. d Additional clipping was performed on the proximal side to prevent the nylon loop from detaching.

Video 1 Endoscopic closure using a purse-string suture for a cecal–sigmoid fistula.

Zoom
Fig. 3 Colonoscopy 4 months after fistula closure revealed a cecal – sigmoid fistula as observed from: a the sigmoid colon; b the cecum. c Elective colonography confirmed a cecal – sigmoid fistula of 4 mm in diameter, meaning a 10.8-mm endoscope could no longer be passed through it.

The efficacy of anti-TNFα agents for fistulas in Crohn’s disease is limited, and the number of fistulas is a predictor of the closure rate [2]. In recent years, endoscopic purse-string sutures and endoscopic closure using over-the-scope clips (OTSCs) have been applied not only to massive gastrointestinal perforations during endoscopic submucosal dissection, but also to intestinal fistulas, enterocutaneous fistulas, and gastrogastric fistulas, among others [3] [4] [5].

This is the first report of endoscopic fistula closure in a patient with Crohn’s disease. Asymptomatic internal fistulas can be followed up, but for patients with Crohn’s disease who have symptomatic fistulas, such as the one reported here, endoscopic fistula closure is a minimally invasive procedure and should be considered as a viable treatment option.

Endoscopy_UCTN_Code_TTT_1AQ_2AG

Endoscopy E-Videos is a free access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high
quality video and all contributions are
freely accessible online.

This section has its own submission
website at
https://mc.manuscriptcentral.com/e-videos


Competing interests

The authors declare that they have no conflict of interest.


Corresponding author

Satohiro Matsumoto, MD, PhD
Department of Gastroenterology
Saitama Medical Center
Jichi Medical University
1-847 Amanuma, Omiya, Saitama
Saitama 330-8503
Japan   
Fax: +81-48-6485188   

Publication History

Article published online:
19 June 2020

© 2020. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany


Zoom
Fig. 1 Colonoscopy revealed a cecal – sigmoid fistula as observed from: a the sigmoid colon; b the cecum. c Elective colonography revealed a cecal–sigmoid fistula of 10 mm in diameter.
Zoom
Fig. 2 Endoscopic views showing the procedure used to close the fistula. a The operator placed a nylon loop on the margin of the fistula using a two-channel endoscope. b The nylon loop was clipped to the margin of the fistula from the distal to the proximal end on both sides. c The assistant tightened the handle of the nylon loop to narrow it and close the fistula. d Additional clipping was performed on the proximal side to prevent the nylon loop from detaching.
Zoom
Fig. 3 Colonoscopy 4 months after fistula closure revealed a cecal – sigmoid fistula as observed from: a the sigmoid colon; b the cecum. c Elective colonography confirmed a cecal – sigmoid fistula of 4 mm in diameter, meaning a 10.8-mm endoscope could no longer be passed through it.