Thorac Cardiovasc Surg 1982; 30(5): 281-283
DOI: 10.1055/s-2007-1022406
DOI: 10.1055/s-2007-1022406
Bioprosthetic Replacement of the Tricuspid Valve
Further Information
Publication History
1982
Publication Date:
19 March 2008 (online)
PDF Download(opens in new window) Permissions and Reprints(opens in new window) All articles of this category(opens in new window)

Summary
From 1976 to 1981, 11 patients underwent tricuspid valve replacement with bioprostheses. All but one patient had either previous or concomitant left-sided valvular disease. The mean preoperative functional class was 3.4. The operative mortality was 18% reflecting the compromised preoperative cardiac state of most patients. There were neither early nor late complications, and no deaths related to the tricuspid bioprosthesis after a mean follow-up of 26 months. In particular, no signs of postoperative right heart failure have been observed clinically.
Key words
Bioprosthesis - Tricuspid valve replacement