Thorac Cardiovasc Surg 1986; 34(6): 389-390
DOI: 10.1055/s-2007-1022180
Case Report

© Georg Thieme Verlag Stuttgart · New York

Management of Immediate Graft Failure after Cardiac Transplantation using Cardiopulmonary Bypass and Intraaortic Balloon-pumping followed by Cardiac Retransplantation

Th. Wahlers, K. Frimpong-Boateng, A. Haverich, H.-J. Schäfers, H. G. Fieguth, R. Coppola, M. Jurmann, H. G. Borst
  • Division of Thoracic and Cardiovascular Surgery, Surgical Center, Hannover Medical School, Hannover, FRG
Further Information

Publication History

1986

Publication Date:
19 March 2008 (online)

Preview

Summary

A 37-year-old man underwent cardiac transplantation for diffuse coronary artery disease and malignant arrhythmias. During the harvesting of the donor heart slight distention of the left ventricle was present due to insufficiency of the aortic valve. After explantation of the graft, fusion of 2 cusps was found and a commissurotomy of the aortic valve was performed and the graft transplanted. Despite maximum inotropic support immediate graft failure and aortic insufficiency was present and discontinuation of cardiopulmonary bypass ICPB) was impossible. After replacement of the aortic valve using a bioprosthesis and implantation of an intraaortic balloon-pump, low cardiac output persisted and CPB had to be continued. After 11 hours of normothermic cardiopulmonary bypass and intraaortic balloonpumping a second graft became available and was retransplantated successfully. The postoperative course was uneventful and the patient remains well 3 months after the operation.