Thorac Cardiovasc Surg 1985; 33(4): 248-249
DOI: 10.1055/s-2007-1014131
Case Report

© Georg Thieme Verlag Stuttgart · New York

Acute Thrombosis of a St. Jude Medical Aortic Prosthesis in a Pregnant Woman

P. Donzeau Gouge, A. N'Guyen, B. Touchot, S. Dunica, S. Weber, F. Guerin, A. Piwnica
  • Department of Cardiovascular Surgery, Lariboisiere Hospital, Paris, France
Weitere Informationen

Publikationsverlauf

1984

Publikationsdatum:
19. März 2008 (online)

Summary

A 24-year-old, 4-months pregnant woman developed an acute thrombosis of a St. Jude Medical aortic valve prosthesis. Upon admission, she was in cardiogenic shock. A thrombectomy was achieved in emergency under cardiopulmonary bypass. The patient survived but not the fetus. Diagnosis, surgical procedure, anticoagulation drugs and valve prostheses in pregnant women are discussed.

    >