Little Finger‐to‐Thumb Microvascular Transfer
Weitere Informationen
Publikationsverlauf
Accepted for publication 1998
Publikationsdatum:
08. März 2008 (online)

ABSTRACT
This case report documents a unique thumb reconstruction performed at the authors' institutions. The amputated dominant right thumb of a manual laborer was electively reconstructed with microvascular transfer of the previously partially amputated little finger from the same hand. At 1 year postopera-tively, the patient returned to work with excellent grip and pinch strength, thumb opposition to all digits, and 8 mm of static two-point discrimination. The technical details of the operation are described and compared with other analogous reports in the literature.