Osteosynthesis and Trauma Care 2003; 11: 10-12
DOI: 10.1055/s-2003-42288
Research - Fundamental

© Georg Thieme Verlag Stuttgart · New York

Hydroxyapatite Ceramics for the Treatment of Metaphyseal Defects after Proximal Tibia Fractures: Long-Term Results

W. Linhart1 , D. Briem1 , W. Lehmann1 , J. M. Rueger1
  • 1Hamburg University, School of Medicine, Dept. of Trauma, Hand, and Reconstructive Surgery, Hamburg, Germany
Further Information

Publication History

Publication Date:
24 September 2003 (online)

Preview

Abstract

Between 1992 and 1997 we have treated bone defects in 35 patients with tibial plateau fractures with the bovine hydroxyapatite ceramic Endobon®. The fractures were stabilized by internal plate fixation. In the present paper we report on the long-term results of this method. We found good functional results, with no signs of secondary displacement or complications due to the bone replacement material. Our data show that Endobon® provides good mechanical properties during a long-term follow-up and can be recommended as an alternative to cancellous bone graft for the treatment of tibial plateau fractures.