J Reconstr Microsurg 2002; 18(7): 569-574
DOI: 10.1055/s-2002-35093
Copyright © 2002 by Thieme Medical Publishers, Inc., 333 Seventh Avenue, New York, NY 10001, USA. Tel.: +1(212) 584-4662

Arterialized Venous Free Flaps for Soft-Tissue Reconstruction of Digits: A 40-Case Series

Francesca De Lorenzi1 , René R.W.J. van der Hulst1 , W. F.A. den Dunnen1 , J. J. Vranckx2 , B. Vandenhof2 , C. Francois2 , Willy D. Boeckx1
  • 1Department of Plastic and Reconstructive Surgery, University Hospital of Maastricht, Maastricht, The Netherlands
  • 2Department of Plastic and Reconstructive Surgery, Leuven University Hospital, Leuven, Belgium
Further Information

Publication History

Publication Date:
29 October 2002 (online)

ABSTRACT

When there is not sufficient local tissue available for reconstruction of one or multiple digital defects, distant flap reconstructions are required. Available thin flaps with defined arterial inflow and venous outflow are limited and require the sacrifice of an arterial pedicle. In addition, a functional limitation can occur at the donor site. During the last decades, experimental and clinical attempts have been made in using venous flaps, based just on the venous network for in- and outflow. A 40-case series of arterialized venous free flaps in soft-tissue reconstruction of the digits and hand is presented. Neovessel formation induced by an intact venous plexus within the flap proved clinically to be the survival mechanism. Postoperative congestion was present in all flaps and subsided within 14 days; 92 percent of all flaps eventually survived. In 57.5 percent of cases, total flap survival was observed; in 17.5 percent of flaps, a superficial epidermolysis occurred, not requiring further surgery; in 17.5 percent of flaps, a full-thickness skin necrosis developed, requiring grafting (minor complication); in 7.5 percent of reconstructions, total flap necrosis was observed. Thus, in the authors' experience, when conventional local flaps are not available, arterialized venous free flaps proved to be a successful solution for soft-tissue reconstruction in digits and hands. The authors present the main indications and advantages of arterialized venous free flaps, emphasizing the essential technical steps and the most frequent pitfalls in treatment.

REFERENCES

  • 1 Earley M J, Milner R H. Dorsal metacarpal flaps.  Br J Plast Surg . 1987;  40 333-341
  • 2 Bertelli J A, Khoury Z. Neurocutaneous island flaps in the hand: anatomical basis and preliminary results.  Br J Plast Surg . 1992;  45 586-590
  • 3 Dautel G, Merle M. Direct and reverse dorsal metacarpal flaps.  Br J Plast Surg . 1992;  45 123-130
  • 4 Atasoy E. Reversed cross-finger subcutaneous flap.  J Hand Surg . 1982;  7 481-483
  • 5 Cavanagh S, Pho R W. The reversed radial forearm flap in the severely injured hand: an anatomical and clinical study.  J Hand Surg . 1992;  17B 501-503
  • 6 Joshi B B. A sensory cross-finger flap for use on the index finger.  Plast Reconstr Surg . 1976;  58 210-213
  • 7 Yu N W, Elliot D. Dorsal V-Y advancement flap in digital reconstruction.  J Hand Surg . 1994;  19 91-97
  • 8 Nakayama Y, Soeda S, Kasai Y. Flaps nourished by arterial inflow through the venous system: an experimental investigation.  Plast Reconstr Surg . 1981;  67 328-334
  • 9 Baek S M, Weinberg H, Song Y. Experimental studies in the survival of venous island flaps without arterial inflow.  Plast Reconstr Surg . 1985;  75 88-95
  • 10 Thatte M, Kamdar N, Khakkar D. Static and dynamic computerised radioactive tracer studies on vital dye staining and theoretical mathematical calculations to ascertain the mode of survival of single cephalad channel venous island flaps.  Br J Plast Surg . 1989;  42 405-413
  • 11 Tsai T M, Matiko J. Venous flaps in digital revascularization and replantation.  J Reconstr Microsurg . 1987;  3 113-119
  • 12 Serafin D, Shearin J C, Georgiade N. The vascularization of free flaps: a clinical and experimental correlation.  Plast Reconstr Surg . 1977;  60 233-241
  • 13 Tsur H, Daniller A, Strauch B. Neovascularization of skin flaps: route and timing.  Plast Reconstr Surg . 1980;  66 85-90
  • 14 Gencosmanoglu R, Ulgen O, Yaman C. Mechanisms of viability in rabbit flank venous flaps.  Ann Plast Surg . 1993;  30 60-66
  • 15 Mundy J C, Panje W R. Creation of free flaps by arterialization of the venous system.  Arch Otolaryngol . 1984;  110 221-223
  • 16 Nichter L, Haines P. Arterialised venous perfusion of composite tissue.  Am J Surg . 1985;  150 191-196
  • 17 Voudikis T. An axial pattern flap based on the arterialised venous network: an experimental study in rats.  Br J Plast Surg . 1982;  35 524-529
  • 18 Honda T, Nomura S, Yamauchi S. The possible applications of a composite skin and subcutaneous vein graft in the replantation of amputated digits.  Br J Plast Surg . 1984;  37 607-612
  • 19 Chavoin J P, Rouge D, Vachaud M. Island flaps with an exclusively venous pedicle: report of 11 cases and a preliminary haemodynamic study.  Br J Plast Surg . 1987;  40 149-154
  • 20 Inoue G, Suzuki K. Arterialised venous flap for treating multiple skin defects of the hand.  Plast Reconstr Surg . 1993;  91 299-302
  • 21 Galumbeck M, Freeman B. Arterialised venous flaps for reconstructing soft-tissue defects of the extremities.  Plast Reconstr Surg . 1994;  94 997-1002
  • 22 Xiu Z F, Chen Z J. Clinical applications of venous flaps.  Ann Plast Surg . 1995;  34 518-522
  • 23 Thatte M, Thatte R. Venous flaps.  Plast Reconstr Surg . 1993;  91 747-751
  • 24 Wolff K, Telzrow T, Rudolph K. Isotope perfusion and infrared thermography of arterialised venous flow-through and pedicled venous flaps.  Br J Plast Surg . 1995;  48 61-70
  • 25 Foucher G, Norris R. The venous dorsal digital island flap or the neutral flap.  Br J Plast Surg . 1988;  41 337-343
    >