Endoscopy 2001; 33(10): 843-848
DOI: 10.1055/s-2001-17326
Original Article

© Georg Thieme Verlag Stuttgart · New York

Fixation of a Modified Covered Esophageal Stent: Its Clinical Usefulness for Preventing Stent Migration

C. S. Shim, Y. D. Cho, J. H. Moon, J. O. Kim, J. Y. Cho, Y. S. Kim, J. S. Lee, M. S. Lee
  • Dept. of Internal Medicine, Institute for Digestive Research, Soon Chun Hyang University College of Medicine, Seoul, Korea
Weitere Informationen

Publikationsverlauf

Publikationsdatum:
20. September 2001 (online)

Background and Study Aims: Membrane-covered self-expandable metal stents are effective in preventing tumor ingrowth and stent obstruction in patients with inoperable esophageal cancer, but migration of stents continues to be a major problem. We therefore constructed a modified covered self-expandable esophageal metal stent capable of being fixed using a silk thread. The stent was studied prospectively to define its palliative characteristics and whether it is effective in preventing migration.

Patients and Methods: Modified covered self-expandable metal stents were placed in 17 patients with malignant gastric cardiac cancer involving the esophagogastric junction, 41 patients with esophageal cancer, and three patients with tracheoesophageal fistulas. Clinical and radiographic follow-up examinations were carried out at regular intervals.

Results: Placement of the stent was successful in all patients, with good symptomatic relief and no serious stent-related complications such as esophageal perforation or hemorrhage. Acute stent placement problems, such as incomplete expansion or acute angulation of the stent, were noted in four patients. However, during a mean follow-up period of 7.5 months (range 1 to 17 months), there was no stent migration.

Conclusions: Modified covered self-expandable esophageal metal stents of this type would be very effective in preventing stent migration, especially in patients with malignant gastric cardiac cancer extending to the lower esophagus, those with short-segment esophageal cancer, and those with tracheoesophageal fistulas.

References

  • 1 Ellul J P, Watkinson A, Khan R J, et al. Self-expanding metal stents for the palliation of dysphagia due to inoperable oesophageal carcinoma.  Br J Surg. 1995;  82 1678-1681
  • 2 Shields S J. Esophageal self-expandable metallic stents.  Gastrointest Endosc. 1997;  45 439-442
  • 3 Kozarek R A. Expandable endoprostheses for gastrointestinal stenoses.  Gastrointest Endosc Clin North Am. 1994;  4 279-295
  • 4 Tytgat G NJ, Tytgat S. Esophageal endoprostheses in malignant stricture.  J Gastroenterol. 1994;  29 80-84
  • 5 Ell C, May A, Hann E G. Gianturco-Z stents in the palliative treatment of malignant esophageal obstruction and esophagotracheal fistulas.  Endoscopy. 1995;  27 495-500
  • 6 Ell C, Hochberger J, May A, et al. Coated and uncoated self-expandable metallic stents for malignant stenosis in the upper GI tract.  Am J Gastroenterol. 1994;  89 1496-1500
  • 7 Weigert N, Hoffmann W, Rösch T, et al. Treatment of esophagorespiratory fistulas with silicone-coated self-expanding metal stents.  Gastrointest Endosc. 1995;  41 490-496
  • 8 Kozarek R A, Raltz S, Brugge W R, et al. Prospective multicenter trial of esophageal Z-stent placement for malignant dysphagia and tracheoesophageal fistula.  Gastrointest Endosc. 1996;  44 562-567
  • 9 Wu W C, Katon R M, Saxon R R, et al. Silicone-covered self-expanding metallic stents for the palliation of malignant esophageal obstruction and esophagorespiratory fistulas: experience in 32 patients and a review of the literature.  Gastrointest Endosc. 1994;  40 22-33
  • 10 Kozarek R A, Raltz S, Marcon N, et al. Use of the 25 mm flanged esophageal Z-stent for malignant dysphagia: a prospective multicenter trial.  Gastrointest Endosc. 1997;  46 156-160
  • 11 Oh J H, Lee K H, Park C W, et al. Self-expandable EsophaCoil esophageal prosthesis for malignant esophageal stenosis.  Korean J Gastrointest Endosc. 1995;  15 63-70
  • 12 Cwikiel W, Stridbeck H, Tranberg K G, et al. Malignant esophageal strictures: treatment with a self-expanding nitinol stent.  Radiology. 1993;  187 661-665
  • 13 Watkinson A F, Ellul J, Entwisle K, et al. Esophageal carcinoma: initial results of palliative treatment with covered self-expanding endoprostheses.  Radiology. 1995;  195 821-827
  • 14 Saxon R R, Barton R E, Rosch J. Complications of esophageal stenting and balloon dilatation.  Semin Intervent Radiol. 1994;  11 276-282
  • 15 Ramirez F C, Dennert B, Zierer S T, Sanowski R A. Esophageal self-expandable metallic stents - indication, practice, technique, and complications: results of a national survey.  Gastrointest Endosc. 1997;  45 360-364
  • 16 Symonds C J. A case of malignant stricture of the esophagus illustrating the use of a new form of esophageal catheter.  Trans Chir Soc Lond. 1885;  18 155-158

C.-S. Shim,M.D. 

Digestive Disease Center
Soon Chun Hyang University College of Medicine

657 Hannam-Dong, Yongsan-Ku
Seoul 140-743
Korea


Fax: + 82-2-709-9696

eMail: schidr@hosp.sch.ac.kr