J Reconstr Microsurg 2001; 17(4): 257-262
DOI: 10.1055/s-2001-14517
Copyright © 2001 by Thieme Medical Publishers, Inc., 333 Seventh Avenue, New York, NY 10001, USA. Tel.: +1(212) 584-4662

Fibrin Sealant: A Novel Method of Fixation for an Implantable Ultrasonic MicroDoppler Probe

Timothy J. Bill, Pamela A. Foresman, George T. Rodeheaver, David B. Drake
  • Department of Plastic Surgery, University of Virginia Health Sciences Center, Charlottesville, VA
Further Information

Publication History

Publication Date:
31 December 2001 (online)

ABSTRACT

While free tissue transfer affords the reconstructive microvascular surgeon the ability to provide coverage for complex wounds, the postoperative monitoring of these flaps continues to evolve. The most recent advance has been the development of an implantable microDoppler probe to provide an early warning signal for vascular obstruction. The current system relies on the use of a silicone cuff to secure a 1-mm probe to the outflow vein. The release force to remove the probe from the cuff is reported to be 1/10 of a pound (45 g). A disadvantage of this system is the need for a circumferential, relatively inelastic device around the vein. Should the cuff be too tightly secured to the vein, the potential for outflow obstruction exists. Moreover, if the probe is not well-approximated to the vein, no signal is produced. Finally, the fact that a foreign body remains in the wound after completion of the monitoring period remains a concern. The authors have investigated a new method to adhere the probe, using a commercially available fibrin sealant. The use of this biocompatible substance has the potential to obviate the need for the current method of fixation, and the associated concerns.

REFERENCES

  • 1 Shaw W W. Microvascular free flaps: the first decade.  Clin Plast Surg . 1983;  10 3-20
  • 2 Hidalgo D A, Disa J J, Cordeiro P G, Hu Q Y. A review of 716 consecutive free flaps for oncologic surgical defects: refinement in donor-site selection and technique.  Plast Reconstr Surg . 1998;  102 722-734
  • 3 Jones N F. Intraoperative and postoperative monitoring of microsurgical free tissue transfers.  Clin Plast Surg . 1992;  19 783-797
  • 4 Furnas H, Rosen J M. Monitoring in microvascular surgery.  Ann Plast Surg . 1991;  26 265-272
  • 5 Ubinger C. The Doppler digest.  Cook Vascular Incorporated Product Specifications . 1999;  Summer 1-4
  • 6 Sierra D H. Fibrin sealant adhesive systems: a review of their chemistry, material properties and clinical application.  J Biomater Appl . 1993;  7 309-352
  • 7 Lange K, Boyd L J. The use of fluorescein to determine adequacy of circulation.  Med Clin North Am . 1942;  26 943-952
  • 8 Webster M HC, Patterson J. The photoelectric plethysmograph as a monitor of microvascular anastomoses.  Br J Plast Surg . 1976;  29 182-185
  • 9 Yuen J C, Feng Z. Monitoring free flaps using the laser Doppler flowmeter: five-year experience.  Plast Reconstr Surg . 2000;  105 55-61
  • 10 Parker P M, Fischer J C, Shaw W W. Implantable pulsed ultrasound Doppler cuff long-term monitoring of free flaps: a preliminary study.  Microsurgery . 1984;  5 130-135
  • 11 Roberts J O, Jones B M. Direct anastomotic assessment for postoperative microvascular monitoring.  Ann Plast Surg . 1987;  19 219-224
  • 12 Swartz W M, Jones N F, Cherup L, Klein A. Direct monitoring of microvascular anastomoses with the 20-MHz ultrasonic Doppler probe: an experimental and clinical study.  Plast Reconstr Surg . 1988;  81 149-158
  • 13 Swartz W M, Izquierdo R, Miller M J. Implantable venous Doppler microvascular monitoring: laboratory investigation and clinical results.  Plast Reconstr Surg . 1994;  93 152-163
  • 14 Kind G M, Buntic R F, Bunke G M. The effect of an implantable Doppler probe on the salvage of microvascular tissue transplants.  Plast Reconstr Surg . 1998;  101 1268-1273
  • 15 Brennan M. Fibrin glue.  Blood Rev . 1991;  5 240-244
  • 16 Bergel S. Uber Wirkugen des Fibrins.  Dtsch Med Wochenschr . 1909;  35 633-665
  • 17 Young J Z, Medawar P B. Fibrin suture of peripheral nerves.  Lancet . 1940;  275 126-132
  • 18 Spotnitz W D. Fibrin sealant in the United States: clinical use at the University of Virginia.  Thromb Haemost . 1995;  74 482-485
  • 19 Nagata K, Kawamoto S, Sashida J. Mesh-and-glue technique to prevent leakage of cerebrospinal fluid after implantation of expanded polytetrafluoroethylene dura substitute: technical note.  Neurol Med Chir (Tokyo) . 1999;  39 316
  • 20 Gyo K, Sato H, Yumoto E. Masking the protrusion of the receiver-stimulator of electronic implants in otology.  Ear Nose Throat J . 1997;  76 316-320
  • 21 Hotz G. Alveolar ridge augmentation with hydroxylapatite using fibrin sealant for fixation. Part I: An experimental study.  Int J Oral Maxillofac Surg . 1991;  20 204-207
  • 22 Akizuki S, Yasukawa Y, Takizawa T. A new method of hemostasis for cementless total knee arthroplasty.  Bull Hosp Jt Dis . 1997;  56 222-224
  • 23 Pinnella J W, Spira M, Erk Y. Direct microvascular monitoring with implantable ultrasonic Doppler probes.  J Microsurg . 1982;  3 217-221
  • 24 Padubidri A N, Browne E. A new method of applying fibrin glue at the microvascular anastomotic site: the ``paintbrush'' technique.  Microsurgery . 1996;  17 428-430
  • 25 Isogai N, Cooley B G, Kamiishi H. Clinical outcome of digital replantation using the fibrin glue-assisted microvascular anastomosis technique.  J Hand Surg . 1996;  21B 573-575
  • 26 Marek C A, Amiss Jr R L, Morgan R F. Acute thrombogenic effects of fibrin sealant on microvascular anastomoses in a rat model.  Ann Plast Surg . 1998;  41 415-419
    >