Semin Respir Crit Care Med 2000; 21(6): 505-522
DOI: 10.1055/s-2000-13186
Copyright © 2000 by Thieme Medical Publishers, Inc., 333 Seventh Avenue, New York, NY 10001, USA. Tel.: +1(212) 584-4662

The Role of the D-Dimer in the Diagnosis of Venous Thromboembolism

Gregory S. Ahearn1 , Henri Bounameaux2
  • 1Division of Pulmonary and Critical Care Medicine, Duke University Medical Center, Durham, North Carolina
  • 2Division of Angiology and Hemostasis, Department of Internal Medicine, University Hospital of Geneva, Geneva, Switzerland
Further Information

Publication History

Publication Date:
31 December 2000 (online)

ABSTRACT

Classic enzyme-linked immunosorbent assay (ELISA) D-dimer assays are sensitive in screening for thromboembolic disease; however, they are cumbersome and time consuming to perform, which limits their routine use. Latex agglutination assays are easier to perform, but they are not as sensitive as the ELISA assays. New D-dimer assays incorporating novel technologies can be performed rapidly with a sensitivity approaching that of classic ELISA assays. D-dimer assays are uniformly sensitive in detecting thromboembolic disease in different patient populations; however, low specificity limits the clinical utility of D-dimer measurements in medical inpatients and postoperative patients. Increasingly, these measurements are being incorporated into diagnostic algorithms for venous thromboembolism and are reducing the need for invasive diagnostic studies.

REFERENCES

  • 1 Bounameaux H, Moerloose P, Reber G. Plasma measurement of D-dimer as diagnostic aid in suspected venous thromboembolism: an overview.  Thromb Haemost . 1994;  71 1-6
  • 2 Elms M J, Bunce I H, Bundesen P G. Rapid detection of cross-linked fibrin degradation products in plasma using monoclonal antibody-coated latex particles.  Am J Clin Pathol . 1986;  85 360-364
  • 3 Bounameaux H, de Moerloose P, Perrier A, Miron M J. D-dimer testing in suspected venous thromboembolism: an update.  Q J Med . 1997;  90 437-442
  • 4 Buller H R, Lensing A WA, Hirsh J, ten Cate W J. Deep vein thrombosis: new non-invasive tests.  Thromb Haemost . 1991;  66 133-137
  • 5 Agnelli G, Volpato R, Radicchia S. Detection of asymptomatic deep vein thrombosis by real-time B-mode ultrasonography in hip surgery patients.  Thromb Haemost . 1992;  68 257-260
  • 6 Tapson V F, Carroll B A, Davidson B L. The diagnostic approach to acute venous thromboembolism. Clinical practice guideline. American Thoracic Society.  Am J Resp Crit Care Med. . 1999;  160 1043-1066
  • 7 de Moerloose P, Michiels J J, Bounameaux H. The place of D-dimer testing in an integrated approach of patients suspected of pulmonary embolism.  Semin Thromb Hemost . 1998;  24 409-412
  • 8 Boneu B, Bes G, Pelzer H. D-dimers, thrombin antithrombin III complexes and prothrombin fragments F1 + 2: diagnostic value in clinically suspected deep vein thrombosis.  Thromb Haemost . 1991;  65 28-32
  • 9 Van Bergen P M M F, Knot E A, Jonker J JC. Is quantitative determination of fibrin(ogen) degradation products and anti-thrombin III complexes useful to diagnose deep venous thrombosis in outpatients?.  Thromb Haemost . 1989;  62 1043-1045
  • 10 Hansson P O, Erikson H, Erikson E. Can laboratory testing improve screening strategies for deep vein thrombosis at an emergency unit?.  J Int Med . 1994;  235 143-151
  • 11 Speiser W, Mallek R, Koppensteiner R. D-dimer and TAT measurement in patients with deep venous thrombosis: utility in diagnosis and judgement of anticoagulant treatment effectiveness.  Thromb Haemost . 1990;  64 196-201
  • 12 Demers C, Ginsberg J S, Johnston M. D-dimer and thrombin anti-thrombin III complexes in patients with clinically suspected pulmonary embolism.  Thromb Haemost . 1992;  67 408-412
  • 13 Leitha T, Speiser W, Dudczak R. Pulmonary embolism: efficacy of D-dimer and thrombin anti-thrombin III complex determinations as screening tests before lung scanning.  Chest . 1991;  100 1536-1541
  • 14 Koppert P W, Hoegee-de Nobel E, Nieuwenhuizen W. A monoclonal antibody-based enzyme immunoassay for fibrin degradation products in plasma.  Thromb Haemost . 1988;  59 310-315
  • 15 Elms M J, Bunce I H, Bundensen P G. Measurement of crosslinked fibrin degradation products: an immunoassay using monoclonal antibodies.  Thromb Haemost . 1983;  50 591-594
  • 16 Rowbotham B J, Carrol P, Whitaker A N. Measurement of cross-linked fibrin derivatives: use in the diagnosis of venous thrombosis.  Thromb Haemost . 1987;  57 59-61
  • 17 Heaton D C, Billings J D, Hickton C M. Assessment of D dimer assays for the diagnosis of deep vein thrombosis.  J Lab Clin Med . 1987;  110 588-591
  • 18 Ott P, Astrup L, Jensen R H. Assesment of D-dimer in plasma: diagnostic value in the suspected deep venous thrombosis of the leg.  Acta Med Scand . 1988;  224 263-267
  • 19 Chapman C S, Akhtar N, Campbell S. The use of D-dimer assay by enzyme immunoassay and latex agglutination techniques in the diagnosis of deep vein thrombosis.  Clin Lab Haematol . 1990;  12 37-42
  • 20 Chang-Liem G S, Lustermans F ath, van Wersch W J J. Comparison of the appropriateness of the latex and elisa plasma D-dimer determination for the diagnosis of deep venous thrombosis.  Haemostasis . 1991;  21 106-110
  • 21 Dale S, Gogstad G O, Brosstad F. Comparison of three D-dimer assays for the diagnosis of DVT: ELISA, latex and an immunofiltration assay (Nyocard D-dimer).  Thromb Haemost . 1994;  71 270-274
  • 22 Bounameaux H, Schneider P A, Reber G. Measurement of plasma D-dimer for diagnosis of deep venous thrombosis.  Am J Clin Pathol . 1989;  91 82-85
  • 23 Elias A, Aillaud M F, Roul C. Assesment of D-dimer measurement by ELISA or latex methods in deep vein thrombosis diagnosed by ultrasound duplex scanning.  Fibrinolysis . 1990;  4 237-240
  • 24 Heijboer H, Ginsberg J S, Buller H R. The use of the D-dimer test in combination with non-invasive testing versus serial non-invasive testing for the diagnosis of deep-vein thrombosis.  Thromb Haemost . 1992;  67 510-513
  • 25 Tengborn L, Palmblad S, Wojciechowski J. D-dimer and thrombin/anti-thrombin III complex-diagnostic tools in deep venous thrombosis?.  Haemostasis . 1994;  24 344-350
  • 26 Bongard O, Wicky J, Peter R. D-dimer plasma measurement in patients undergoing major hip surgery: use in the prediction and diagnosis of postoperative proximal vein thrombosis.  Thromb Res . 1994;  75 487-493
  • 27 Elias A, Aptel I, Huc B. D-dimer test and diagnosis of deep vein thrombosis: a comparative study of 7 assays.  Thromb Haemost . 1996;  76 518-522
  • 28 Borg J Y, Levesque H, Cailleux N. Rapid quantitative D-dimer assay and the clinical evaluation for the diagnosis of clinically suspected DVT.  Thromb Haemost . 1997;  77 602-603
  • 29 Leroyer C, Escoffre M, Moigne E L. Diagnostic value of a new sensitive membrane based technique for instantaneous D-dimer evaluation in patients with clinically suspected deep venous thrombosis.  Thromb Haemost . 1997;  77 637-640
  • 30 Freyberger G, Trillaud H, Labrouche S. D-dimer strategy in thrombosis exclusion.  Thromb Haemost . 1998;  79 32-37
  • 31 Wahlander K, Tengborn L, Hellstrom M. Comparison of various D-dimer tests for the diagnosis of deep vein thrombosis.  Blood Coagul Fibrinolysis . 1999;  10 121-126
  • 32 Rowbotham B J, Whitaker A N, Harrison J. Measurement of crosslinked fibrin derivatives in patients undergoing abdominal surgery: use in the diagnosis of postoperative venous thrombosis.  Blood Coagul Fibrinolysis . 1992;  3 25-30
  • 33 Carter C J, Doyle D L, Dawson N. Investigations into the clinical utility of the latex D-dimer in the diagnosis of deep venous thrombosis.  Thromb Haemost . 1993;  69 8-11
  • 34 Brenner B, Pery M, Lanir N. Application of a bedside whole blood D-dimer assay in the diagnosis of deep vein thrombosis.  Blood Coagul Fibrinolysis . 1995;  6 219-222
  • 35 Legnani C, Pancani C, Palareti G. Comparison of new rapid methods for D-dimer measurement to exclude deep vein thrombosis in symptomatic outpatients.  Blood Coagul Fibrinolysis . 1997;  8 296-302
  • 36 Legnani C, Pancani C, Palareti G. Contribution of a new, rapid, quantitative and automated method for D-dimer measurement to exclude deep vein thrombosis in symptomatic outpatients.  Blood Coagul Fibrinolysis . 1999;  10 69-74
  • 37 Janssen M CH, Heebels A E, de Metz M. Reliability of five rapid D-dimer assays compared to ELISA in the exclusion of deep venous thrombosis.  Thromb Haemost . 1997;  77 262-266
  • 38 Scarano L, Bernardi E, Prandoni P. Accuracy of two newly described D-dimer tests in patients with suspected deep venous thrombosis.  Thromb Res . 1997;  86 93-99
  • 39 Scarano L, Prandoni P, Gavasso S. Failure of soluble fibrin polymers in the diagnosis of clinically suspected deep vein thrombosis.  Blood Coagul Fibrinolysis . 1999;  10 245-250
  • 40 Raimondi P, Bongard O, Moerloose P. D-dimer plasma concentrations in various clinical conditions: implications for the use of this test in the diagnostic approach of venous thromboembolism.  Thromb Res . 1993;  69 125-130
  • 41 Bounameaux H, Schneider P A, Slosman D. Plasma D-dimer in suspected pulmonary embolism: a comparison with pulmonary angiography and ventilation perfusion scintigraphy.  Blood Coagul Fibrinolysis . 1990;  1 577-579
  • 42 Bounameaux H, Cirafici P, de Moerloose P. Measurement of D-dimer in plasma as diagnostic aid in suspected pulmonary embolism.  Lancet . 1991;  337 196-200
  • 43 Duet M, Benelhadj S, Kedra W. A new quantitative D-dimer assay appropriate in emergency: reliability of the assay for pulmonary embolism exclusion diagnosis.  Thromb Res . 1998;  91 1-5
  • 44 Meyer G, Fischer A M, Collignon M A. Diagnostic value of two rapid and individual D-dimer assays in patients with clinically suspected pulmonary embolism: comparison with microplate enzyme-linked immunoabsorbant assay.  Blood Coagul Fibrinolysis . 1998;  9 603-608
  • 45 Perrier A, Desmarais S, Goehring C. D-dimer testing for suspected pulmonary embolism in outpatients.  Am J Respir Crit Care Med . 1997;  156 492-495
  • 46 Quinn D A, Fogel R B, Smith C D. D-dimers in the diagnosis of pulmonary embolism.  Am J Respir Crit Care Med . 1999;  159 1445-1449
  • 47 Reber G, Vissac A M, de Moerloose P. A new semi-quantitative and individual ELISA for rapid measurement of plasma D-dimer in patients suspected of pulmonary embolism.  Blood Coagul Fibrinolysis . 1995;  6 460-463
  • 48 Tardy B, Tardy-Poncet B, Viallon A. Evaluation of D-dimer ELISA test in elderly patients with suspected pulmonary embolism.  Thromb Haemost . 1998;  79 38-41
  • 49 Bounameaux H, Slosman D, de Moerloose P, Reber G. Diagnostic value of plasma D-dimer in suspected pulmonary embolism.  Lancet . 1988;  2 628-629
  • 50 Ginsberg J S, Brill-Edwards P A, Demers C. D-dimer in patients with clinically suspected pulmonary embolism.  Chest . 1993;  104 1679-1684
  • 51 Bonnin F, Hadjikostova H, Jebrak G. Complementarity of lung scintigraphy and D-dimer test in pulmonary embolism.  Eur J Nucl Med . 1997;  24 444-447
  • 52 Quinn R J, Nour R, Butler S. Pulmonary embolism in patients with intermediate probability lung scans: diagnosis with doppler venous US and D-dimer measurement.  Radiology . 1994;  190 509-511
  • 53 Veitl M, Hamwi A, Kurtaren A. Comparison of four rapid D-dimer tests for diagnosis of pulmonary embolism.  Thromb Res . 1996;  82 399-407
  • 54 Goldhaber S Z, Vaughan D E, Tumeh S S, Loscalzo J. Utility of cross-linked fibrin degradation products in the diagnosis of pulmonary embolism.  Am Heart J . 1988;  116 505-508
  • 55 Rylatt D B, Blake A S, Cottis L E. An immunoassay for human D-dimer using monoclonal antibodies.  Thromb Res . 1983;  31 767-778
  • 56 de Boer A W, de Haan A M, Huisman J W, Klaassen C HL. D-dimer latex assay as screening method in suspected deep venous thrombosis of the leg. A clinical study and review of the literature.  Neth J Med . 1991;  38 65-69
  • 57 Crippa L, Ravasi F, D'Angelo S V. Diagnostic value of compression ultrasonography and fibrinogen-related parameters for the detection of postoperative deep vein thrombosis following elective hip replacement: a pilot study.  Thromb Haemost . 1995;  74 1235-1239
  • 58 Grau E, Linares M, Estany A. Utility of D-dimer in the diagnosis of deep vein thrombosis in outpatients.  Thromb Haemost . 1991;  66 510
  • 59 Johanning J M, Veverka T J, Bays R A. Evaluation of suspected pulmonary embolism utilizing end-tidal CO2 and D-dimer.  Am J Surg . 1999;  178 98-102
  • 60 Kutinsky I, Blakley S, Vivyenne R. Normal D-dimer levels in patients with pulmonary embolism.  Arch Intern Med . 1999;  159 1569-1572
  • 61 Kline J A, Meek S, Boudrow D. Use of the alveolar dead space fraction (Vd/Vt) and plasma D-dimers to exclude acute pulmonary embolism in ambulatory patients.  Acad Emer Med . 1997;  4 856-863
  • 62 Harrison K A, Haire W D, Pappas A A. Plasma D-dimer: a useful tool for evaluating suspected pulmonary embolus.  J Nucl Med . 1993;  34 896-898
  • 63 Pappas A A, Dalrymple G, Harrison K. The application of a rapid D-dimer test in suspected pulmonary embolus.  Arch Pathol Lab Med . 1993;  117 977-980
  • 64 Gogstad G O, Dale S, Brosstad F. Assay of D-dimer based on immunofiltration and staining with gold colloids.  Clin Chem . 1993;  39 2070-2076
  • 65 Khira H S, Mann J. Plasma D-dimer measurement in patients with suspected DVT: a means of avoiding unnecessary venography.  Eur J Vasc Endovasc Surg . 1998;  15 235-238
  • 66 Killick S B, Pnetek P G, Mercieca J E. Comparison of immunofiltration assay of D-dimer with diagnostic imaging in deep vein thrombosis.  Br J Haematol . 1997;  96 846-849
  • 67 Lindahl L, Lundahl T H, Ranby M. Clinical evaluation of a diagnostic strategy for deep venous thrombosis with exclusion by low plasma levels of fibrin degradation product D-dimer.  Scand J Clin Lab Invest . 1998;  58 307-316
  • 68 Turkstra F, van Beek J R E, ten Cate W J, Buller H R. Reliable rapid blood test for the exclusion of venous thromboembolism in symptomatic outpatients.  Thromb Haemost . 1996;  76 9-11
  • 69 Mayer W, Hirschwehr R, Hippman G. Whole blood immunoassay (SimpleRED) versus plasma immunoassay (NycoCard) for the diagnosis of clinically suspected deep vein thrombosis.  Vasa . 1997;  26 97-101
  • 70 D'Angelo A, D'Alessandro G, Tomassini L. Evaluation of a new rapid quantitative D-dimer assay in patients with clinically suspected deep vein thrombosis.  Thromb Haemost . 1996;  75 412-416
  • 71 Perrier A, Desmarais S, Miron M J. Non-invasive diagnosis of venous thromboembolism in outpatients.  Lancet . 1999;  353 190-195
  • 72 Wells P S, Brill-Edwards P, Stevens P. A novel and rapid whole-blood assay for D-dimer in patients with clinically suspected deep vein thrombosis.  Circulation . 1995;  91 2184-2187
  • 73 Knecht M F, Heinrich F. Clinical evaluation of an immunoturbidimetric D-dimer assay in the diagnostic procedure of deep vein thrombosis and pulmonary embolism.  Thromb Res . 1997;  88 413-417
  • 74 Miron M J, Perrier A, Bounameaux H. Contribution of noninvasive evaluation to the diagnosis of pulmonary embolism in hospitalized patients.  Eur Respir J . 1999;  13 1365-1370
  • 75 de Moerloose P, Desmarais S, Bounameaux H. Contribution of a new, rapid, individual and quantitative D-dimer ELISA to exclude pulmonary embolism.  Thromb Haemost . 1996;  75 11-13
  • 76 Ergermeyer P, Town G I, Turner J G. Usefulness of D-dimer, blood gas and respiratory rate measurements for excluding pulmonary embolism.  Thorax . 1998;  53 830-834
  • 77 Ginsberg J S, Wells P S, Brill-Edwards P. Application of a novel and rapid whole blood assay for D-dimer in patients with clinically suspected pulmonary embolism.  Thromb Haemost . 1995;  73 35-38
  • 78 Ginsberg J S, Wells P S, Kearon C. Sensitivity and specificity of a whole-blood assay for D-dimer in the diagnosis of pulmonary embolism.  Ann Intern Med . 1998;  129 1006-1011
  • 79 Vissac A M, Grimaux M, Chartier S. A new sensitive membrane based ELISA technique for instantaneous D-dimer evaluation in emergency.  Thromb Res . 1995;  78 341-352
  • 80 John M A, Elms M J, O'Reilly E J. The SimpliRED D dimer test: a novel assay for the detection of crosslinked fibrin degradation products in whole blood.  Thromb Res . 1990;  58 273-281
  • 81 Lennox A F, Nicolaides A N. Rapid D-dimer testing as an adjunct to clinical findings in excluding pulmonary embolism.  Thorax . 1999;  54 S33-S36
  • 82 Oger E, Leroyer C, Bressollette L. Evaluation of a new, rapid, and quantitative D-dimer test in patients with suspected pulmonary embolism.  Am J Respir Crit Care Med . 1998;  158 65-70
  • 83 Kario K, Matsuo T, Kabayashi H. Rapid quantitative evaluation of plasma D-dimer levels in thrombotic states using an automated latex photometric immunoassay.  Thromb Res . 1992;  66 179-189
  • 84 Ginsberg J S, Kearon C, Douketis J. The use of D-dimer testing and impedance plethysmographic examination in patients with clinical indications of deep vein thrombosis.  Arch Intern Med . 1997;  157 1077-1081
  • 85 Bernardi E, Prandoni P, Lensing A W. D-dimer testing as an adjunct to ultrasonography in patients with clinically suspected deep venous thrombosis: prospective cohort study. The Multicentre Italian D-dimer Ultrasound Study Investigators Group.  BMJ . 1998;  317 1037-1040
  • 86 The PIOPED Investigators. Value of the ventilation/perfusion scan in acute pulmonary embolism: results of the prospective investigation of pulmonary embolism diagnosis (PIOPED).  JAMA . 1990;  263 2753-2759
  • 87 Perrier A, Bounameaux H, Morabia A. Contribution of D-dimer plasma measurement and lower-limb venous ultrasound to the diagnosis of pulmonary embolism: a decision analysis model.  Am Heart J . 1994;  127 624-635
  • 88 Perrier A, Bounameaux H, Moraba A. Diagnosis of pulmonary embolism by a decision analysis based strategy including clinical probability, D-dimer levels and ultrasonography: a management study.  Arch Intern Med . 1996;  156 531-536
  • 89 Hadjiliadis D, Klemp K F, Govert J A. Elevated D-dimer levels in patients admitted to the medical intensive care unit (MICU): prevalence and association with outcomes.  AJRCCM . 2000;  161 A94
  • 90 Kollef M H, Eisenberg P R, Shannon W. A rapid assay for the detection of circulating D-dimer is associated with clinical outcomes in critically ill patients.  Crit Care Med . 1998;  26 1054-1060
  • 91 Bounameaux H, Khabiri E, Huber O. Value of liquid crystal contact thermography and plasma levels of D-dimer for screening of deep venous thrombosis after general surgery.  Thromb Haemost . 1992;  67 603-606
  • 92 Baker W F. Current concepts in thrombosis: Prevalent trends for the diagnosis and management.  Med Clin North Am . 1998;  82 460-476
  • 93 Mottier D, Couturaud F, Oger E. Clinical usefulness of D-dimer tests in excluding pulmonary embolism is highly dependent upon age.  Thromb Haemost . 1998;  80 527
  • 94 Kario K, Matsuo T, Kobayashi H. Which factors affect high D-dimer levels in the elderly?.  Thromb Res . 1991;  62 501-508
  • 95 Cadroy Y, Pierrejean D, Fontan B. Influence of age on the hemostatic system: Prothrombin fragment F1 + 2, thrombin antithrombin III complexes and D-dimers in 80 healthy subjects with age range from 20 to 94 years.  Nouv Rev Fr Hematol . 1992;  34 43-46
    >