RSS-Feed abonnieren
DOI: 10.1055/s-0045-1805547
EUS-guided Tissue Acquisition for the Diagnosis of Solid Lesions, role of the newly designed Acquire-S needle
Aims to evaluate the diagnostic accuracy of EUS-guided tissue acquisition performed with the newly designed Acquire-S needle in the differential diagnosis of solid lesions.
Methods The study identified patients from a prospective EUS registry who underwent EUS-guided tissue acquisition for solid lesions using the new Acquire-S needles (Boston Scientific), a franseen type needle with a modified taper point stylet. The EUS procedures were performed using linear Pentax or Fujifilm echoendoscopes and Hitachi systems. For tissue acquisition, both 25-gauge and 22-gauge Acquire-S needles were used. Samples were collected in a cytological solution (Cytolit) processed for cyto-histological evaluation. Results are shown as mean±standard deviation or percentages as appropriate. Diagnostic accuracy was analyzed using the histopathological evaluation of the surgical specimens, and the clinical and radiological long-term follow-up in non-operated patients, as gold standard.
Results 89 patients (mean age 63.7 years [range 37-86 years], 41 females) were finally included. The average size of the lesions was 26.8±19.5 mm. 51 (57.3%) were solid pancreatic lesions, 17 (19.1%) lymph nodes, 5 (5.6%) solid liver lesions, 4 (4.5%) subepithelial lesions, 4 (4.5%) gastric tumors, 3 (3.5%) lesions at left adrenal gland, 2 (2.2%) ampullary lesions, 1 (1.1%) duodenal lesion, 1 (1.1%) renal tumor, and 1 (1.1%) peritoneal implant. For tissue acquisition, in 8 (8.9%) cases the access was transesophageal, in 48 (53.9%) cases transgastric and in 33 (37.2%) cases the access was transduodenal. A 25-gauge needle was used in 30 cases (33.7%) and a 22-guage needle in 59 cases (66.3%). The mean number of passes was 1.3±0.4. In 11 cases the final diagnosis was a benign lesion, being a malignant lesion the remaining 78 cases. In 4 cases (4.5%), there was a need to exchange the needle size (2 solid pancreatic lesions at pancreatic tail, 1 at uncinate process and 1 liver lesion), in 3 cases from a 22-gauge to a 25-gauge, and in 1 from 25-gaugen to 22-gauge (all Acquire-S). Diagnostic sensitivity, specificity, positive predictive value, negative predictive value and overall accuracy for malignancy were 86.89% (95%CI 77.6-96.2); 96.43% (95%CI 87.8-100); 98.2% (955CI 93.6-10); 77.1% (95%CI 61.8-82.5) and 89.9% (95%CI 83.1-96.7), respectively. A specific final diagnosis could be obtained in 80 cases (89.9%). No complications were reported.
Conclusions EUS-guided tissue acquisition with the newly designed Acquire-S needle is very accurate and safe in the evaluation of solid lesions.
Publikationsverlauf
Artikel online veröffentlicht:
27. März 2025
© 2025. European Society of Gastrointestinal Endoscopy. All rights reserved.
Georg Thieme Verlag KG
Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany