Accidental Puncture of a Dialysis Catheter into the Brachiocephalic Trunk

Mohamad Syafeeq Faeez Md Noh
1   Department of Imaging, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, Selangor, Malaysia
2   Department of Radiology, Universiti Putra Malaysia (UPM) Teaching Hospital, Serdang, Selangor, Malaysia
› Author Affiliations
Funding None.

Abstract

A 22-year-old male with underlying end-stage renal failure was referred to our center for a malpositioned dialysis catheter. Imaging showed the tip of the catheter to be placed in the brachiocephalic trunk; the patient was, however, asymptomatic. Surgical removal of the malpositioned catheter followed, with no postoperative complications.



Publication History

Received: 09 April 2019

Accepted: 20 June 2020

Article published online:
23 December 2020

© 2020. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Pikwer A, Acosta S, Kölbel T, Malina M, Sonesson B, Akeson J. Management of inadvertent arterial catheterisation associated with central venous access procedures. Eur J Vasc Endovasc Surg 2009; 38 (06) 707-714
  • 2 Guilbert MC, Elkouri S, Bracco D. et al. Arterial trauma during central venous catheter insertion: case series, review and proposed algorithm. J Vasc Surg 2008; 48 (04) 918-925 , discussion 925
  • 3 Othman H, Rosman H, Saravolatz L, Rama K. Aortic cannulation: an unexpected complication of central venous catheter placement. J Cardiothorac Vasc Anesth 2017; 31 (03) e52-e53