J Reconstr Microsurg 2020; 36(06): 466-470
DOI: 10.1055/s-0040-1703014
Original Article
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Changes to Venous Flow Coupler Signal during DIEP Flap Inset Can Be Predictive of Poor Clinical Outcomes in Autologous Breast Reconstruction

1   Division of Plastic and Reconstructive Surgery, University of Colorado Hospital, Aurora, Colorado
,
1   Division of Plastic and Reconstructive Surgery, University of Colorado Hospital, Aurora, Colorado
,
Jaclyn Anderson
1   Division of Plastic and Reconstructive Surgery, University of Colorado Hospital, Aurora, Colorado
,
David Woodbridge Mathes
1   Division of Plastic and Reconstructive Surgery, University of Colorado Hospital, Aurora, Colorado
,
Tae Woon Chong
1   Division of Plastic and Reconstructive Surgery, University of Colorado Hospital, Aurora, Colorado
› Author Affiliations
Further Information

Publication History

26 November 2019

20 January 2020

Publication Date:
15 March 2020 (online)

Abstract

Background Venous flow couplers are typically used to monitor free flaps during the postoperative period, with a continuous venous signal available immediately after completion of the anastomosis. Intraoperative loss of the coupler signal is not uncommon and may require adjustments in free flap inset and even flap thickness to get the venous signal to return. The effects of intraoperative coupler signal loss and the role of this technology on flap outcomes have not been evaluated. We hypothesized that the use of intraoperative coupler can be protective of both early and late flap complications by preventing unfavorable flap insets.

Patients and Methods All patients who underwent free flap breast reconstruction between January 2018 and June 2019 by single microsurgery team were included. Flap inset and inset changes based on flow coupler signal problems were reviewed in the procedure notes. Patient demographics data and clinical outcomes were analyzed with comprehensive chart review.

Results Forty-four consecutive patients with 69 free flaps were identified. There were no significant differences in patient characteristics or venous coupler size used in venous anastomosis. Although the number of operating room take backs for venous insufficiency was not significantly different between two groups, the free flaps with inset change had significantly higher complications that required later surgical intervention (p = 0.0464).

Conclusion Surgeons should be aware that intraoperative coupler signal loss can be associated with poor clinical outcomes postoperatively and these flaps may require more perfusion imaging, flap debulking, or even additional venous anastomosis.

 
  • References

  • 1 Yang Q, Ren ZH, Chickooree D. , et al. The effect of early detection of anterolateral thigh free flap crisis on the salvage success rate, based on 10 years of experience and 1072 flaps. Int J Oral Maxillofac Surg 2014; 43 (09) 1059-1063
  • 2 Siemionow M, Arslan E. Ischemia/reperfusion injury: a review in relation to free tissue transfers. Microsurgery 2004; 24 (06) 468-475
  • 3 Paydar KZ, Hansen SL, Chang DS, Hoffman WY, Leon P. Implantable venous Doppler monitoring in head and neck free flap reconstruction increases the salvage rate. Plast Reconstr Surg 2010; 125 (04) 1129-1134
  • 4 Lin SJ, Nguyen MD, Chen C. , et al. Tissue oximetry monitoring in microsurgical breast reconstruction decreases flap loss and improves rate of flap salvage. Plast Reconstr Surg 2011; 127 (03) 1080-1085
  • 5 Lenz Y, Gross R, Penna V, Bannasch H, Stark GB, Eisenhardt SU. Evaluation of the implantable Doppler probe for free flap monitoring in lower limb reconstruction. J Reconstr Microsurg 2018; 34 (03) 218-226
  • 6 Guillemaud JP, Seikaly H, Cote D, Allen H, Harris JR. The implantable Cook-Swartz Doppler probe for postoperative monitoring in head and neck free flap reconstruction. Arch Otolaryngol Head Neck Surg 2008; 134 (07) 729-734
  • 7 Chang TY, Lee YC, Lin YC. , et al. Implantable Doppler probes for postoperatively monitoring free flaps: efficacy. a systematic review and meta-analysis. Plast Reconstr Surg Glob Open 2016; 4 (11) e1099
  • 8 Fujiwara RJT, Dibble JM, Larson SV, Pierce ML, Mehra S. Outcomes and reliability of the flow coupler in postoperative monitoring of head and neck free flaps. Laryngoscope 2018; 128 (04) 812-817
  • 9 Fitzgerald O'Connor E, Rozen WM, Chowdhry M. , et al. The microvascular anastomotic coupler for venous anastomoses in free flap breast reconstruction improves outcomes. Gland Surg 2016; 5 (02) 88-92
  • 10 Senthil Murugan M, Ravi P, Mohammed Afradh K, Tatineni V, Krishnakumar Raja VB. Comparison of the efficacy of venous coupler and hand-sewn anastomosis in maxillofacial reconstruction using microvascular fibula free flaps: a prospective randomized controlled trial. Int J Oral Maxillofac Surg 2018; 47 (07) 854-857
  • 11 Bar-Meir ED, Yueh JH, Tobias AM, Lee BT. Autologous fat grafting: a technique for stabilization of the microvascular pedicle in DIEP flap reconstruction. Microsurgery 2008; 28 (07) 495-498
  • 12 Caulfield RH, Georgeu G, Niranjan NS. A method for protecting the anastomosis in deep inferior epigastric artery perforator flap breast reconstruction. J Reconstr Microsurg 2008; 24 (02) 93-94
  • 13 Gravvanis A, Kakagia D, Samouris G, Galani E, Tsoutsos D. Tips and outcomes of a new DIEP flap inset in delayed breast reconstruction: the dual-plane technique. J Reconstr Microsurg 2016; 32 (05) 366-370
  • 14 Nikkhah D, Bayne D, Drury P, Hazari A. Avoiding compression of the DIEP pedicle at inset. Microsurgery 2016; 36 (03) 261-262
  • 15 Mulvey CL, Cooney CM, Daily FF. , et al. Increased flap weight and decreased perforator number predict fat necrosis in DIEP breast reconstruction. Plast Reconstr Surg Glob Open 2013; 1 (02) 1-7
  • 16 Szabo Eltorai A, Huang CC, Lu JT, Ogura A, Caterson SA, Orgill DP. Selective intraoperative vasopressor use is not associated with increased risk of DIEP flap complications. Plast Reconstr Surg 2017; 140 (01) 70e-77e
  • 17 Wade RG, Razzano S, Sassoon EM, Haywood RM, Ali RS, Figus A. Complications in DIEP flap breast reconstruction after mastectomy for breast cancer: a prospective cohort study comparing unilateral versus bilateral reconstructions. Ann Surg Oncol 2017; 24 (06) 1465-1474
  • 18 Marre D, Hontanilla B. Increments in ischaemia time induces microvascular complications in the DIEP flap for breast reconstruction. J Plast Reconstr Aesthet Surg 2013; 66 (01) 80-86
  • 19 Sultan SM, Jackson DS, Erhard HA. , et al. Risk factors for postoperative venous thromboembolic complications after microsurgical breast reconstruction. J Reconstr Microsurg 2018; 34 (04) 227-234
  • 20 Qiu CS, Jordan SW, Dorfman RG, Vu MM, Alghoul MS, Kim JYS. Surgical duration impacts venous thromboembolism risk in microsurgical breast reconstruction. J Reconstr Microsurg 2018; 34 (01) 47-58
  • 21 Janes LE, Hui-Chou HG, Matthews JA, Sabino J, Singh DP. Utilization of near-infrared indocyanine green angiography for immediate and delayed venous outflow assessment in breast reconstruction: a case report. Plast Reconstr Surg Glob Open 2014; 2 (01) e100
  • 22 Rao SS, Parikh PM, Goldstein JA, Nahabedian MY. Unilateral failures in bilateral microvascular breast reconstruction. Plast Reconstr Surg 2010; 126 (01) 17-25